6640--DxFLEX System - Cleveland

VETERANS AFFAIRS, DEPARTMENT OF

Notice type
Combined Synopsis/Solicitation
Solicitation #
36C25026Q0639
NAICS
334516
PSC
6640
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
June 12, 2026
Response due
June 12, 2026
Place of performance
Cleveland, OH

What this opportunity is

The Department of Veterans Affairs is seeking to purchase a DxFLEX Flow Cytometer for the Pathology and Laboratory Service Department at the Louis Stokes Cleveland VA Medical Center. This opportunity is set aside for total small businesses under NAICS code 334516, which pertains to Analytical Laboratory Instrument Manufacturing. Interested vendors should note that this is a combined synopsis/solicitation, meaning they will need to submit quotes rather than waiting for a formal solicitation document.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

SUBJECT* DxFLEX System - Cleveland GENERAL INFORMATION CONTRACTING OFFICE’S ZIP CODE* 44131 SOLICITATION NUMBER* 36C25026Q0639 RESPONSE DATE/TIME/ZONE 06-12-2026 2:00 pm EASTERN TIME, NEW YORK, USA ARCHIVE 15 DAYS AFTER THE RESPONSE DATE RECOVERY ACT FUNDS N SET-ASIDE SBA PRODUCT SERVICE CODE* 6640 NAICS CODE* 334516 CONTRACTING OFFICE ADDRESS Department of Veterans Affairs Network Contracting Office (NCO) 10 6150 Oak Tree Blvd., Suite 300 Independence OH 44131 POINT OF CONTACT* Contract Specialist Jennifer A. Tisdale jennifer.tisdale@va.gov 216-447-8010 None PLACE OF PERFORMANCE ADDRESS Department of Veterans Affairs Louis Stokes Cleveland VA Medical Center 10701 East Blvd. Pathology & Laboratory Service Cleveland Ohio POSTAL CODE 44106 COUNTRY US ADDITIONAL INFORMATION AGENCY’S URL http://www.va.gov URL DESCRIPTION Department of Veterans Affairs AGENCY CONTACT’S EMAIL ADDRESS Jennifer A. Tisdale EMAIL DESCRIPTION Contract Specialist DESCRIPTION DESCRIPTION This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format Revolutionary FAR Overhaul (RFO) in Federal Acquisition Regulation (FAR) subpart 12.202, “Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services,” as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ 36C25026Q0639. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC)2026-01. This solicitation is Small Business set-aside, under FAR Part 12. The associated North American Industrial Classification System (NAICS) code for this procurement is 334516, Analytical Laboratory Instrument Manufacturing with a business size standard of 1000. The FSC/PSC is 6640. The Department of Veterans Affairs, Network Contracting Office (NCO)10, Louis Stokes Cleveland VA Medical Center 10701 East Blvd., Cleveland, Ohio 44106 is seeking to purchase the following equipment, DxFlex Flow Cytometer for the Pathology and Laboratory Service Department. All interested companies shall provide quotations for the following, Brand Name Only: Supplies/Services requested: Line Item Item/Product Description Quantity Unit of Measure 1 C78505 DxFLEX System B5-R3-V5 with Auto-Loader NA 01 EA 2 D07919 CEVID Display 01 EA 3 D18853 DxFlex Workstation 01 EA 4 C43911 Printer, DGTL, Color, Laser, LEXMARK, CS521DN USB / 120V 01 EA 5 C64335 DxFlex Service Installation without Training 04 EA 6 C81703 Flow Application Support 1 Day 01 EA 7 D12505 DxFlex Customer Training at Beckman Coulter Site 01 EA 8 B73613 DxFLEX Sheath Fluid 01 EA 9 C39283 DxFLEX Daily QC Fluorospheres 01 EA 10 C48093 FLOW CLEAN IVD, 500ML – EU 01 EA 11 81911 Contrad 70, 1 X 1 LITER 01 EA 12 C10576 SWRE KIT,KALUZA C 10 User Network License 01 EA 13 OPTIONAL: D21047 IT Informatics Support Service Contract 01 EA Statement of Work (SOW): Contract Number: Task Order Number: IFCAP Tracking Number: 541-26-2-250-0085 Follow-on to Contract and Task Order Number: 1. Contracting Officer’s Representative (COR). Name: Section: PALMS; VAMC Cleveland; VISN 10 Address: 10701 E. BLVD Cleveland OH 44106 Phone Number: Fax Number: E-Mail Address: 2. Contract Title. DxFLEX Flow Cytometer with Autoloader and CytExpert software System. 3. Background: LAB BACKGROUND Our laboratory currently performs leukemia/lymphoma immunophenotyping by flow cytometry. To increase the quality, safety, and throughput of patient testing, we propose acquiring the Beckman Coulter DxFLEX Flow Cytometer with the DxFLEX Autoloader and CytExpert for DxFLEX software. The DxFLEX is FDA-cleared in the United States for 10-color in vitro diagnostic use with the ClearLLab 10C Reagent System, enabling a much faster path to clinical go-live compared with developing and validating laboratory-developed tests (LDTs). The DxFLEX platform will streamline sample preparation and data acquisition, improve result accuracy, and reduce manual hands-on time and reagent waste. CLINICAL NEED AND RATIONALE We require a modern clinical flow cytometer with automated sample loading, barcode-based positive identification, and stable multicolor detection to support high-confidence leukemia/lymphoma panels. The DxFLEX meets these needs by combining a compact, integrated optical design, high sensitivity detectors, and workflow-oriented CytExpert software with bi-directional LIS connectivity. 4. Scope: The contractor shall provide the following: PERFORMANCE ADVANTAGES •Up to 10-color FDA-cleared clinical configuration for ClearLLab 10C (instrument hardware supports up to 13 fluorescence channels for RUO). •Three solid-state lasers for robust multicolor detection: 405 nm (Violet), 488 nm (Blue), and 638 nm (Red). •High sensitivity for dim populations: ≤30 MESF-FITC, ≤10 MESF-PE, <50 MESF-PB450, and <25 MESF-APC. •Fully, digital electronics providing 7 decades (orders of magnitude) dynamic range for accurate separation of populations. •Nominal acquisition rate of 30,000 events per second with up to 15 parameters (13 fluorescence channels plus forward/side scatter). •Carryover control with observed beads carryover as low as 0.006% in validation studies (≤0.5% specification). •Optimized scatter resolution to resolve lymphocytes, monocytes, granulocytes, red blood cells, and platelets. EASE OF USE AND WORKFLOW IMPROVEMENTS •DxFLEX Autoloader supports up to 32 (12 × 75 mm) tubes with single-tube mixing and integrated barcode reader for positive sample identification. •Compact footprint with onboard fluidics (4

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Similar Active Opportunities (NAICS 334516)