Airfield Lighting Control System Upgrade (ALCMS), Fairchild AFB

DEPT OF DEFENSE

Notice type
Sources Sought
Solicitation #
FA462026QA277
NAICS
513210
PSC
7J20
Set-aside
No Set aside used
Posted
June 9, 2026
Response due
June 11, 2026
Place of performance
Fairchild AFB, WA

What this opportunity is

The Department of Defense is seeking to modernize the Airfield Lighting Control System (ALCMS) at Fairchild Air Force Base, focusing on hardware and software upgrades to enhance cybersecurity and comply with FAA and DOD standards. This opportunity is not set aside for small businesses, and only the original manufacturer, ADB SAFEGATE, is authorized to perform the required modifications due to the proprietary nature of the software. As this is a Sources Sought notice, interested firms should prepare to respond with capability statements but will need to wait for a separate solicitation to submit bids.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

DRAFT CUI CUI STATEMENT OF WORK FOR ALCMS and Cyber Upgrade June 2026 FA462026QA277 Attach. 1 - Statement of Work Draft 1 of 3 -- 1 of 3 -- DRAFT CUI CUI Statement of Work (SOW) For ALCMS and Cyber Upgrade Fairchild AFB, WA 1. BACKGROUND: Fairchild Air Force Base (AFB) currently operates an ADB SAFEGATE L-890 Airfield Lighting Control System (ALCMS). This system requires a comprehensive upgrade to modernize its components and enhance its cybersecurity posture to align with current Department of Defense (DOD) and U.S. Air Force (USAF) standards. The existing system's hardware and software need to be serviced and modified to conform with FAA AC150/5345-56 specifications and relevant sections of DAFGM 2023-32-01. Due to the proprietary nature of the ALCMS software, only the original manufacturer, ADB SAFEGATE, is authorized to perform the required modifications to ensure the system's life-safety functionality is not compromised. This project will provide Fairchild AFB with a new, updated Airfield Lighting Control and Monitoring System. 2. SCOPE OF WORK: The Contractor shall provide Fairchild Air Force Base with a new Airfield Lighting Control and Monitoring System (ALCMS), including a comprehensive cybersecurity upgrade. This involves replacing and upgrading core hardware, software, and network components to move the system from a serial-based to an IP-based ethernet communication architecture. 3. OBJECTIVES: The primary objective of this contract is to replace and upgrade the existing ALCMS to a modern, cyber-compliant system. The end product will be a fully commissioned, tested, and secure ALCMS that provides reliable control and monitoring of the airfield lighting systems, meeting current FAA and USAF requirements. The upgraded system will enhance functionality, maintainability, and security for safe airfield operations. 4. REQUIREMENTS: The Contractor shall furnish all necessary equipment, materials, and services to complete the ALCMS and Cyber Upgrade. The tasks include: • System Upgrade: • Replace ALCMS CPU equipment at the Air Traffic Control Tower (ATCT) and Vault nodes with new Industrial Microbox style CPUs running Windows 11. • Replace all fiber drivers and unmanaged network switches with new managed fiber switches. • Provide and install ACE 3 Door Upgrade kits for all 28 existing switchgear CCRs (24 5-step, 4 3-step). • Update the ALCMS touchscreen Human Machine Interface (HMI) with new graphics to support the transition to ethernet IP communication. • Install three (3) ACE 3 I/O units for monitoring and control of vault and remote I/O locations (SFL05, SFL23, Traffic Lights). • Cybersecurity Enhancements: • Deploy the ALCMS with Windows 11 24H2 (or current certified version). • Achieve 80% or greater compliance with STIG/SRG standards (January 1, 2025 baseline). • Configure managed switches to lock down non-populated ports. • Implement password protection for maintenance tools. • Generate and deliver SHA-256 hash values at commissioning to establish a configuration integrity baseline. • Services: • Provide technical submittals for approval prior to production. • Conduct Factory Acceptance Testing (FAT) and On-Site Commissioning and System Acceptance Testing (SAT). • Perform on-site installation, system checks, and commissioning over a series of four one-week site visits. • Provide two 1-hour training sessions for ATC personnel and one 6-hour training session for maintenance personnel. • Deliver project documentation, including as-installed drawings and operator manuals. FA462026QA277 Attach. 1 - Statement of Work Draft 2 of 3 -- 2 of 3 -- DRAFT CUI CUI 5. GOVERNMENT FURNISHED EQUIPMENT AND SERVICES: The government is not required to furnish any equipment for this project. The government shall provide the Contractor with access to all required work sites, including the ATCT and airfield lighting vault. 6. SECURITY REQUIREMENTS: All personnel employed by the Contractor in the performance of this contract, or any representative of the Contractor entering the government installation, shall abide by all Fairchild Air Force Base security regulations. Personnel performing the work requested will be escorted for the duration on the installation. Individuals must be able to pass a background check that will be conducted prior to entry of the installation. Individuals performing the work will be required to provide their full name, DOB, SSN, driver’s license issuing state and license number to gain access to the installation. 7. PLACE OF PERFORMANCE: The work shall be performed at Fairchild Air Force Base, WA. Specific locations include the Air Traffic Control Tower (ATCT), the airfield lighting vault, and remote I/O control sites for SFLs and Traffic Lights. 8. PERIOD OF PERFORMANCE:| The period of performance will be determined after contract award. The delivery of equipment is contingent upon the review and approval of the Submittal phase (Milestone M2). The on-site work is planned to be completed over four separate one-week trips. 9. GENERAL INFORMATION: 9.1. HOURS OF OPERATION: Hours of operation are 0700-1630 Monday through Friday, excluding Federal Holidays and any other designated down day. Work can be done at other than the normal hours of operation with the approval of the Contracting Officer. The contractor shall coordinate in advance all hours of work and any service interruptions with points of contact at the 92d Civil Engineer Squadron. January 1 New Year’s Day 3rd Monday in January Martin Luther King, Jr. Day 3rd Monday in February President’s Day Last Monday in May Memorial Day June 19 Juneteenth July 4 Independence Day 1st Monday in September Labor Day 2nd Monday in October Columbus Day November 11 Veterans Day 4th Thursday in November Thanksgiving Day December 25 Christmas 10. APPENDICES: N/A FA462026QA277 Attach. 1 - Statement of Work Draft 3 of 3 -- 3 of 3 --

Source: SAM.gov, as posted. Verify the current solicitation before responding.