Barge Overhaul Services - Portsmouth Naval Shipyard

DEPT OF DEFENSE

Notice type
Combined Synopsis/Solicitation
Solicitation #
N3904026Q4819
NAICS
336611
PSC
J019
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
June 9, 2026
Response due
June 22, 2026
Place of performance
Kittery, ME

What this opportunity is

The Department of Defense is seeking total small business set-aside bids for barge overhaul services at the Portsmouth Naval Shipyard in Maine. This project involves inspecting and repairing the underwater hull of a barge, including visual inspections and ultrasonic testing to assess structural integrity. Interested small businesses should note that this is a combined synopsis/solicitation notice, which means they should track the opportunity closely and prepare to submit proposals based on the detailed requirements outlined in the solicitation.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

SHIP: NAVSUPPACT PORTSMOUTH NSY (CNIC 32446) ITEM NO: 110-11-001 COAR: 16 PCN: SERV-L071 CMP: NONE PLANNER: ROBERTS, JEARLD DEMERS, RAY SSP: BOST-503-26 1 of 3 ITEM NO: 110-11-001 1. SCOPE: 1.1 Title: Underwater Hull; inspect and repair 1.2 Location of Work: 1.2.1 Underwater Hull, Sides, Bow and Stern 1.3 Identification: 1.3.1 Not Applicable 2. REFERENCES: 2.1 NAVSEA Standard Items, (FY-26) 2.2 100-7010379 Rev 0, Open Lighter YC 1646 Series Bottom Plating and Sections 2.3 100-7010381 Rev 1, Open Lighter YC 1646 Series Side Plating & Details 2.4 100-7010378 Rev 0, Open Lighter YC 1646 Series Scantling and Sections 2.5 101-4799508, Open Lighter YC 1523 Series Hull Structure & Arrangement 2.6 T9074-AS-GIB-010/271 Rev 1, Requirements for Nondestructive Testing Methods 2.7 MIL-STD-2035A (SH) Rev A, Nondestructive Testing Acceptance Criteria 3. REQUIREMENTS: 3.1 Accomplish a visual inspection within the first 24 hours after drydocking of Barge, upon completion of the hydro pressure water wash cleaning of the underwater hull and prior to painting, from the bottom of the keel to the upper boottop limit, including shell plating, sea chests, skegs and structural members for structural integrity, deterioration, pitting, cracks and areas of damage or distortion, using 2.2 through 2.5 for guidance. Report: INSPECTION RESULTS (WC) - WORK COMPLETE + 3 days 3.1.1 Submit one legible copy, in hard copy or approved transferrable media, of a report listing conditions found to the Barge Master/COR. (CDRL A001) 3.2 Accomplish ultrasonic tests on the underwater hull plating, within 72 hours of drydocking, in 200 locations, as designated by the Barge Master/COR, in accordance with Chapter 6 of 2.6, using 2.2 through 2.5 -- 1 of 36 -- SHIP: NAVSUPPACT PORTSMOUTH NSY (CNIC 32446) SSP: BOST-503-26 2 of 3 ITEM NO: 110-11-001 for guidance. 3.2.1 The accept or reject criteria must be in accordance with Paragraph 8 of 2.7. Report: SKETCH AND UT READINGS (WC) - WORK COMPLETE + 3 days 3.2.2 Submit one legible copy, in hard copy or approved transferrable media, of a sketch which includes specific locations with respect to frames, strakes, port or starboard, and existing welded butts and seams to the Barge Master/COR. (CDRL A002) 3.2.2.1 Sketch must show location of each reading, original material thickness, existing material thickness, and percentage of material thickness reduction to the Barge Master/COR. 3.2.2.2 Notate if reading is taken over existing doubler plate. 3.3 Accomplish repairs resulting from the visual inspection in 3.1 and ultrasonic testing results of 3.2 in locations as designated by the Barge Master/COR, using 2.2 through 2.5 as follows: 3.3.1 Vee-out and weld repair a total of 500 linear feet of splits, cracks, deteriorated and damaged welds. 3.3.2 Clad weld a total of 1000 square inches of plating defects. 3.3.2.1 Surfaces must be ground to smooth metal prior to welding. 3.3.2.2 Fill local pits and grooves with weld metal prior to the application of principal build-up layers. 3.3.3 Install new a total of 500 square feet of 15.3# mild steel doubler plating in areas of deteriorated hull plating as designated by the Barge Master/COR. 3.3.4 Accomplish the requirements of 009-012 of 2.1, including Table 3, Column A, Lines One through 7. 3.3.4.1 Accomplish nondestructive testing in accordance with Line 11. (V)(G) "AIR HOSE TEST OR WATER HOSE TEST " 3.3.5 Accomplish the requirements of 009-025 of 2.1 for the local air hose or water hose test of each repaired area. Allowable leakage: None. 3.4 Accomplish the requirements of 009-032 of 2.1 for each new and disturbed surface. 4. NOTES: 4.1 Work in conjunction with Work Item 123-21-001; Void; clean, inspect and preserve and 631-31-001, Underwater Hull and Freeboard Preservation; accomplish. 5. GOVERNMENT FURNISHED MATERIAL (GFM): -- 2 of 36 -- SHIP: NAVSUPPACT PORTSMOUTH NSY (CNIC 32446) SSP: BOST-503-26 3 of 3 ITEM NO: 110-11-001 5.1 LLTM: 1. None. 5.2 PUSH MATERIAL: 1. None. 5.3 KITTED MATERIAL: 1. None. -- 3 of 36 -- SHIP: NAVSUPPACT PORTSMOUTH NSY (CNIC 32446) ITEM NO: 123-21-001 COAR: 16 PCN: SERV-L072 CMP: NONE PLANNER: ROBERTS, JEARLD DEMERS, RAY SSP: BOST-503-26 1 of 5 ITEM NO: 123-21-001 1. SCOPE: 1.1 Title: Void; clean, inspect, and preserve 1.2 Location of Work: 1.2.1 Throughout the Barge 1.2.1.1 Forward Rake Void (1-7-1) 1.2.1.2 Forward Rake Void (1-7-2) 1.2.1.3 Void (1-16-1) 1.2.1.4 Void (1-16-2) 1.2.1.5 Void (1-26-1) 1.2.1.6 Void (1-26-2) 1.2.1.7 Void (1-29-1) 1.2.1.8 Void (1-29-2) 1.2.1.9 Void (1-38-1) 1.2.1.10 Void (1-38-2) 1.2.1.11 Void (1-47-1) 1.2.1.12 Void (1-47-2) 1.3 Identification: 1.3.1 Quantity (12 EA), Void 1.3.1.1 Quantity (11 EA), Associated 15-inch X 23-inch Raised Bolted Access Cover 1.3.1.2 Quantity (One EA), Hatch WTRTT, Raised 6-inch Coaming, 36-inch by 42-inch, Individually Dogged, 6 Dog (Access to No. 6 Void) 2. REFERENCES: 2.1 NAVSEA Standard Items, (FY-26) 2.2 100-7010378 Rev 0, Open Lighter YC 1646 Series Scantling & Sections 2.3 100-7010379 Rev 0, Open Lighter YC 1646 Series Bottom Plating and Sections 2.4 100-7010380 Rev 0, Open Lighter YC 1646 Series Deck Plating 2.5 100-7010383 Rev 0, Open Lighter YC 1646 Series Transverse Bhd. & Framing Sections & Details 2.6 100-7010381 Rev 1, Open Lighter YC 1646 Series Side Plating & Detailss 2.7 101-4799508 Rev C, Open Lighter YC-1523 Series Hull Structure and -- 4 of 36 -- SHIP: NAVSUPPACT PORTSMOUTH NSY (CNIC 32446) SSP: BOST-503-26 2 of 5 ITEM NO: 123-21-001 Arrangement 2.8 600-4799512 Rev B, Open Lighter YC-1523 Series General Outfitting Details 2.9 622-7010388 Rev 0, Open Lighter YC-1646 Series Ladder Details and Grating Installation 2.10 805-1624079 Rev F, Hatch W.T. Raised Individually Dogged 36" X 60" without Scuttle 15 P.S.I. Arrangement 2.11 805-1624071 Rev D, Hatch W.T. Raised Individually Dogged, Dog, Hinge, Brace and Misc. Details 2.12 803-2226372 Rev C, Doors, Hatches, and Scuttles, General Notes 3. REQUIREMENTS: (V)(G) "JOINT VISUAL INSPECTION" 3.1 Accomplish

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Similar Active Opportunities (NAICS 336611)