Full and Open Competition Construct Metal Building, F5067 Vance AFB, OK

DEPT OF DEFENSE

Notice type
Combined Synopsis/Solicitation
Solicitation #
FP1024054
NAICS
236220
PSC
Y1EB
Set-aside
No Set aside used
Posted
June 3, 2026
Response due
June 17, 2026
Place of performance
Enid, OK

What this opportunity is

The Department of Defense is seeking contractors for a full and open competition to construct a metal building at Vance Air Force Base, Oklahoma, under NAICS code 236220. This opportunity is not set aside for small businesses, meaning any qualified contractor can bid. The notice type is a combined synopsis/solicitation, indicating that interested parties should prepare to submit proposals rather than simply track the opportunity.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

Design Percent Completion: 100% May 1, 2026 Statement of Work CONSTRUCT METAL BUILDING, F5067 VANCE AIR FORCE BASE, OKLAHOMA FACILITY PROJECT ID 1024054 PREPARED BY DYLAN MARTIN, ZEB MCCOLLUM AND JOMARA ORTIZ -- 1 of 134 -- 400 Young Road Vance AFB, OK 73705 580.213.7174 FP1024054 Page 1 of 19 Construct Metal Building, F5067 SoW Version 4.0 INDEX PART 1 GENERAL ....................................................................................................................................... 2 1.01. PROJECT DESCRIPTION ..................................................................................................................... 2 1.02. INSTRUCTIONS TO BIDDERS ............................................................................................................. 2 1.03. LOCATION OF WORK ........................................................................................................................ 2 1.04. SCOPE OF WORK .............................................................................................................................. 2 1.05. CHANGES ........................................................................................................................................ 11 1.06. WARRANTY..................................................................................................................................... 11 1.07. SCHEDULE OF WORK ...................................................................................................................... 12 1.08. WORK RESTRICTIONS ..................................................................................................................... 12 1.09. CONTRACTOR’S REPRESENTATIVE ................................................................................................. 14 1.10. PROVIDED SERVICES AND UTILITIES .............................................................................................. 15 1.11. INSPECTION .................................................................................................................................... 15 1.12. EXCESS MATERIALS (EXCLUDING HAZARDOUS MATERIALS OR WASTE) ....................................... 15 1.13. SPECIAL MATERIALS ....................................................................................................................... 15 1.14. MATERIALS ..................................................................................................................................... 16 PART 2 EXECUTION.................................................................................................................................. 17 2.01. SITE SAFETY REQUIREMENTS ......................................................................................................... 17 2.02. INSTALLATION ................................................................................................................................ 17 PART 3 SITE INFORMATION ..................................................................................................................... 18 PART 4 APPENDICES ................................................................................................................................ 19 4.01. APPENDIX A – BID FORM ............................................................................................................... 21 4.02. APPENDIX B – SPECIFICATIONS ...................................................................................................... 23 4.03. APPENDIX C – DRAWINGS .............................................................................................................. 79 4.04. APPENDIX D – SCHEDULE E ............................................................................................................ 90 4.05. APPENDIX E – BASIS OF DESIGN DETAILS ....................................................................................... 94 -- 2 of 134 -- 400 Young Road Vance AFB, OK 73705 580.213.7174 FP1024054 Page 2 of 19 Construct Metal Building, F5067 SoW Version 4.0 PART 1 GENERAL 1.01. PROJECT DESCRIPTION A. The work covered under this Statement of Work shall consist of constructing a 40-foot by 60-foot, prefabricated metal building, complete-in-place (turnkey) and any incidental work necessary to provide a complete and usable finished product. 1.02. INSTRUCTIONS TO BIDDERS A. As part of the bid package the Contractor shall submit a completed copy of APPENDIX A – BID FORM, along with all required documentation as stated in Sam.gov. 1.03. LOCATION OF WORK A. Location of work to be accomplished under this statement of work is at Vance Air Force Base (AFB). Vance AFB is located three miles south of the City of Enid, Oklahoma. Facility 5067 will be constructed Northeast of the intersection of Conway Street and Macchi Avenue. 1.04. SCOPE OF WORK A. The Contractor shall furnish all supervision, labor, equipment, consumable materials, supplies, tools, and other items to complete the construction as listed in the Scope of Work. All quotes shall include all shipping charges for completion of the project. The contractor will coordinate all work with ASRC Federal (ASRC) Construction Management prior to execution. The list of items below are to be considered the general Scope of Work for the project. B. The Contractor shall field verify location of work, dimensions, and existing site conditions prior to commencing work. The Contractor shall contact ASRC Construction Management for any discrepancies with the Scope of Work. C. The Contractor shall furnish and construct a complete and usable, 40-foot wide by 60- foot-long pre-fabricated metal building with Portland Cement (P.C.) concrete slab, footings, doors, spray foam insulation, electrical lighting and power, electrical heating, PC concrete building approaches, sidewalks and entrance drive. Additional details are described below: -- 3 of 134 -- 400 Young Road Vance AFB, OK 73705 580.213

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Similar Active Opportunities (NAICS 236220)