GAOA Housing Facility Upgrades

AGRICULTURE, DEPARTMENT OF

Notice type
Combined Synopsis/Solicitation
Solicitation #
127EAW26Q0027
NAICS
236220
PSC
Y1FZ
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
June 11, 2026
Response due
June 30, 2026
Place of performance
CA

What this opportunity is

The USDA is seeking a contractor for facility upgrades at the Oak Grove Fire Station in California, specifically for the demolition and removal of a Hotshot Barracks building. This opportunity is set aside for total small businesses under NAICS 236220, making it suitable for small contractors specializing in construction and facility upgrades. Interested businesses should note that this is a combined synopsis/solicitation, indicating that they should track the opportunity closely for further details and bidding instructions.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

US Department Of Agriculture (USDA) GAOA Housing Oak Grove Facility Upgrades – Hotshot Barracks Statement of Work and Specifications Notice The following document incorporates the Statement of Work and Specifications for the GAOA Housing – Oak Grove Facility Upgrades – Hotshot Barracks. These sections outline the project requirements, performance expectations, and technical standards. • The Statement of Work begins on Page 2. • The Specifications begin on Page 8. 1 -- 1 of 110 -- GAOA HOUSING OAK GROVE FACILITY UPGRADES – HOTSHOT BARRACKS FACILITY UPGRADES STATEMENT OF WORK 1.1 SCOPE OF WORK Project Location: Oak Grove Fire Station, San Diego County, Palomar Ranger District Oak Grove Fire Station, 37560 Highway 79 South, Warner Springs, CA 92086, San Diego County. From San Diego, California, travel north on Interstate 15 for ~ 50 miles to Temecula and take the Temecula Parkway/Highway 79 South exit. Turn right and travel east for ~ 20 miles to the Oak Grove Fire Station on the right (south) side of the highway. All work and products shall meet applicable California Building Standards Code (CBSC), California Plumbing Code (CPC), California Electrical Code (CEC), California Mechanical Code (CMC), California Health and Safety Codes (HSC), California Department of Housing and Community Development (HCD), US Department Housing & Urban Development (HUD), Code of Federal Regulations (29 CFR), and State (Title 8) OSHA, Title 24 California Code of Regulations (CCR), and Title 25 California Code of Regulations (CCR), Americans With Disabilities Act/Architectural Barriers Act (ADAABA) Guidelines, latest edition, in addition to other required regulations as stated in the Specifications and Contract Documents. Where there is a conflict between applicable regulations, the most stringent shall apply. The work shall be waterproof, rodent proof, and weathertight. All products used shall be nonrusting type. The project consists of work included here, but not limited to: Base Bid: Oak Grove Fire Station Hot Shot Barracks 1. Work shall include the following: • Building Demolition of one Hotshot Barracks Building (Infra #5305), approximately 1312 square feet, three bedrooms, two bath, modular building with asphalt shingle roof, built 2002. Removal and disposal of entire building, foundation and footings, all interior and exterior utilities, appliances, furnishings and fixtures, deck, ramp and stairs. Photos provided are representative of style/type of furnishings, appliances and fixtures but are not all inclusive. • Exterior utilities (water, septic, leach) shall be cut and capped at both ends a minimum eighteen inches below grade and abandon existing lines in place. Backfill and compact slab, footing and utility areas with imported material to restore the site to its natural conditions. • Remove and dispose of existing concrete propane tank pad, regulator, fittings, posts, and lines. • Furnish and install a new 20’x4’x4” minimum propane tank pad for a 1000 gallon propane tank, bollards, regulator, fittings, and lines and connect underground to new building. Removal of existing propane tank and delivery of new propane tank shall be coordinated with the Forest Service • Existing septic tank shall be pumped and completely removed, void shall be backfilled with imported material and compacted. • Furnish and install septic system with 4000 gallon septic tank and infiltrator chamber leach field and connect to new building. • Existing water shall be disconnected from building temporarily. New waterline shall be furnished, installed and connected to new building and tied into existing waterline in a new valve box with a new shut off valve.2 -- 2 of 110 -- GAOA HOUSING OAK GROVE FACILITY UPGRADES – HOTSHOT BARRACKS FACILITY UPGRADES • Contractor shall coordinate with San Diego Gas & Electric for electric meter, panel, subpanel, boxes, lines and associated work. Disconnect existing electrical meter, panel, lines, boxes and subpanels, panel board and dispose. Install and connect new electrical meter, panel, subpanel, panel board, pole, lines, boxes, service and incidentals for new building requirements of 200 Amp service. Install and connect new service from location as required by SDGE to new building in accordance with San Diego Gas & Electric requirements. Remaining electrical boxes, posts, panels, subpanels, lines and appurtenances shall be removed and disposed. • All existing phone lines shall be temporarily disconnected and reconnected to new building. • All ground disturbance shall be minimized. The contract work area is twenty feet beyond building footprint in all directions, with the exception of utility locations and leach field. No other ground disturbance shall take place. • Hazardous material sampling and testing shall be completed, and abatement if hazardous materials are found. See the Specifications for the guidelines for sampling and testing, removal and disposal of hazardous materials. 2. Furnish and install one new fully finished, move in ready, manufactured home including delivery and set up, utility installation, utility connections/reconnections and all site work. Site work shall include walkways, ramp, stairs, and all utilities (water, electrical, phone, septic, leach, and propane) including incidentals. Building shall be AAAmerican Pacific Manufactured Home, 619-449-3800, Skyline Model 67 CUSTOM HUD, ~1760 square feet, 27 feet x 66 feet, five bedrooms, and three baths with details and layout as shown in Specification 13 34 19, Manufactured Building, or approved equal. The location of the new building shall be in the same location as the existing Barracks Building (Infra #5305) being demolished. Additive Item #1: Hazardous Material Abatement, Removal and Disposal 1. Abatement, removal and disposal of all hazardous materials. The Oak Grove Fire Station is located on approximately eleven acres, and there are barracks, an engine garage, offices, warehouse, and training buildings nea

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Similar Active Opportunities (NAICS 236220)