GOX Trailer Modification and Recertification
NATIONAL AERONAUTICS AND SPACE ADMINISTRATION
Notice type
Combined Synopsis/Solicitation
Solicitation #
80NSSC26936486Q
NAICS
332999
PSC
5680
Posted
July 6, 2026
Response due
July 8, 2026
Place of performance
Hampton, VA
What this opportunity is
The government is buying modification and recertification of a high-pressure, gaseous oxygen tube trailer, which suits businesses with a NAICS code of 332999. This is a combined synopsis and solicitation, meaning businesses should track the opportunity closely as it proceeds directly to bid. The work will be performed in Virginia, and the contractor will be responsible for picking up and delivering the trailer to NASA Langley Research Center.
Analysis by Mindy, grounded in the SAM.gov notice.
Description
Statement of Work for LARCPR-XXXX
Subject:
Requester:
Recertification of high-pressure, gaseous oxygen tube trailer
NASA Asset NA00204T (#1364)
Statement of Work - Modification and Recertification of D.O.T. Trailer
Line Item 1: Recertification
Inspect, modify, and certify as follows:
1. Perform quinquennial disassembly, painting, hydrostatic pressure test, and precision internal
cleaning of one (1) Government-owned gaseous oxygen tube trailer in accordance with the
current DOT regulations and NASA requirements in this Statement of Work.
2. Remove and replace the current two (2) Sherwood valves with new 1882 Sherwood valves.
These valves shall have stem threaded above the packing.
3. Add two new HP2000 pneumatic-actuated valves located on manifold where two pressure
indicators/hand valves are located.
4. Trailer shall be returned filled with product as per procedures outlined in this Statement of
Work.
5. Price shall include pick-up and delivery to NASA Langley Research Center, Hampton, VA.
Description of Trailer
Trailer License No.: 1364
Type of Gas: UHP Oxygen
Semi-Trailer Comp: MH-1
Overall Trailer Length: 282 inch
Overall Trailer Width: 96 inch
Overall Trailer Height: 97 inch
Type of Cylinders: ICC 3A-2400
Manufacturer: Standard Steel Works, North Kansas City, MO
Approx. length of cylinders: 21 feet
-- 1 of 4 --
Outside diameter of cylinders: 9-5/8 inch
Number of cylinders: 30
Approx. water volume of each cylinder @ 70°F: 9 cu. ft.
DOT Re-Test Due Date: 2026
Requirements
All procedures shall be performed in accordance with applicable DOT, CGA, and NASA regulations and
requirements specified.
Price shall include pick-up and delivery to NASA Langley Research Center, Hampton, VA. The government
will ensure that the trailer is road worthy and will be empty with placards and labels that indicate the
trailer is empty.
Procedure
1) The Contractor shall disassemble the subject tube trailer into its individual bottles, manifolds, and
connected plumbing hardware.
2) The contractor shall inspect all valves, fittings, and pressure relief devices (PRD's), and replace or
refurbish any that are compromised, or fail to meet functional intent. Compromised includes all
damage to NGT and NPT threadings that would reduce the integrity of connections.
a) All elastomers and lubricants used in the components shall be rated “A” for mechanical impact
test of 6700 psi per KTI-5210 Revision C (SEE SOW
ATTACHMENT A) unless approved by the contracting officer.
b) All metallic items used shall be Type 316 Stainless Steel (S31600) or a metal with a higher
“Promoted Ignition Lowest Burn Pressure” per Table 2 of KTI-5120 Revision C.
c) The contractor shall provide material certifications for all new components, elastomers, and
lubricants used.
3) The contractor shall inspect the internals of the cylinders and remove all deleterious material
including rust, Teflon tape, and any other foreign material that could present blockage flow through
valves and connected plumbing.
4) The contractor shall pressure test the cylinders in accordance with DOT and CGA regulations
including CGA C-1, Methods for Hydrostatic Testing of Compressed Gas Cylinders. The contractor
shall take care when using Teflon tape to ensure that excess material is not released into the
cylinders or connected plumbing in the process of performing these tests.
5) The contractor shall:
a) Remove all rust, dirt, and loose paint from the exterior of each of the gas cylinders and other
trailer parts. If sand blasting is to be performed, all other parts of the trailer that could be
damaged by the sand blasting shall be protected.
-- 2 of 4 --
b) Apply one coat of zinc chromate primer, Federal Spec. TI-P-645 or equal, and two coats of Spatz
White Enamel, No. 2109 or equal, to each of the gas cylinders.
c) Treat for any surface corrosion/oxidation properly, and then paint trailer parts with one coat of
epoxy primer or equal, and two finish coats of exterior enamel yellow paint.
d) Apply identifications and markings to trailers in accordance with the latest edition of the
applicable DOT regulations.
6) The contractor shall clean the wetted surfaces of bottles, components, manifold, and all other
wetted surfaces of the tube bank assembly to Level 1000B (or cleaner) per Table 1 “Fluid Surface
Cleanliness Levels” of KSC-C-123J (2009) (SEE SOW ATTACHMENT B).
a) If the contractor cleans, tests, and verifies the surface cleanliness levels per KSC-C-123J then a
certificate shall be signed stating this along with signed cleanliness level verification reports for
the bottles, manifolds, valves, and other components of the tube bank assembly.
b) If the contractor chooses to clean and test for cleanliness with other methods then the
contractor shall submit these procedures for approval by the government prior to beginning
cleaning.
c) Regardless of the cleaning method, the final flush and testing fluid solvent shall be one of those
shown on Table 3 “Solvents, Maximum Allowable Nonvolatile Residue” of KSC-C-123 that does
NOT have note 2 or 3 indicated or another solvent that is tested and certified to satisfy the
requirements of NASA-STD-6001B “Flammability, Odor, Offgassing, and Compatibility
Requirements and Test Procedures for Materials in Environments that Support Combustion”.
d) Following cleaning the components shall be purged dry with Quality Verfication Level (QVL) “Q”
nitrogen per CGA G-10.1-2016 “Commodity Specification for Nitrogen”. The purge gas vessel and
piping system shall be verified to be clean to Level 300A per KSC-C-123F. The purge gas shall be
filtered with a 10 micron filter prior to being introduced into the clean tube trailer components.
7) The contractor shall reassemble the tube trailer while maintaining the cleanliness integrity of the
wetted surfaces.
8) Following completion of hydrostatic testing, painting, cleaning, and reassembly, the contractor shall
pressurize and leak test trailer, including all cylinders, manifolds and c…
Source: SAM.gov, as posted. Verify the current solicitation before responding.
Pursue this opportunity with Mindy
See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.
View the original notice on SAM.gov ↗Similar Active Opportunities (NAICS 332999)
Hull Section, Support Structure and Vehicular Body Panel
DEPT OF DEFENSE · Combined Synopsis/Solicitation · due July 28, 2026
PROP BLADE RH & LH
HOMELAND SECURITY, DEPARTMENT OF · Solicitation · due August 7, 2026
POP-UP SOLID BEAM FINAL DENIAL BARRIER RETROFIT
DEPT OF DEFENSE · Special Notice · due July 31, 2026
AAR Mobility Systems
NATIONAL AERONAUTICS AND SPACE ADMINISTRATION · Combined Synopsis/Solicitation · due July 27, 2026
7125--Instrument Cabinets
VETERANS AFFAIRS, DEPARTMENT OF · Sources Sought · due August 3, 2026
Forward Hadronic Calorimeter Absorber Structures
ENERGY, DEPARTMENT OF · Solicitation · due August 10, 2026