J052--Metasys Calibration SERVICE CONTRACT
VETERANS AFFAIRS, DEPARTMENT OF
Notice type
Sources Sought
Solicitation #
36C26126Q0953
NAICS
334515
PSC
J052
Set-aside
Small Business Set Aside - Total
Posted
August 6, 2026
Response due
August 10, 2026
Place of performance
Fresno
Description
SUBJECT*
Metasys Calibration SERVICE CONTRACT
GENERAL INFORMATION
CONTRACTING OFFICE’S ZIP CODE*
95652
SOLICITATION NUMBER*
36C26126Q0953
RESPONSE DATE/TIME/ZONE
08-10-2026 12:00 PACIFIC TIME, LOS ANGELES, USA
ARCHIVE
14 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N
SET-ASIDE
SBA
PRODUCT SERVICE CODE*
J052
NAICS CODE*
334515
CONTRACTING OFFICE ADDRESS
Department of Veterans Affairs
VA Sierra Pacific Network (VISN 21)
Network Contracting Office (NCO) 21
3237 Peacekeeper Way, Bldg 209
McClellan Park CA 95652
POINT OF CONTACT*
Contract Specialist
Bruce Lundvall
bruce.lundvall@va.gov
916-923-4549
PLACE OF PERFORMANCE
ADDRESS
Metasys Calibration Services
Repair and calibration services
Fresno Ca
POSTAL CODE
COUNTRY
USA
ADDITIONAL INFORMATION
AGENCY’S URL
https://www.va.gov/central-california-health-care/locations/
URL DESCRIPTION
Fresno VA Medical Center
AGENCY CONTACT’S EMAIL ADDRESS
EMAIL DESCRIPTION
DESCRIPTION
The purpose of this sources sought is to obtain information in support of Market Research. Interested vendors are asked to review the attached specifications and provide the following information in their response:
Company Name, Point of contact, Email address
An Informal Quote
Authorized Distributor Letter
Capabilities Statement
Business Size
DUNS Number
Vendor POC information
Any existing IDIQ contracts in which these items can be ordered from (e.g. GSA, NASA SEWP, DLA eCAT, VA SAC, or VA NAC)
This notice is not an official request for quotes. Information obtained from this notice may be used to assist the Agency in determining the strategy for obtaining these items/services. Please note an official request for quote may or may not be released in connection with this notice.
All responses shall be submitted to bruce.lundvalll@va.gov prior to the closing date of this notice.
PERFORMANCE WORK STATEMENT
Project Name: Annual Calibration Metasys
Place of Performance: VACCHCS
2615 E. Clinton Ave
Fresno, CA 93703-2223
Part 1: Project Scope of Work Overview:
The Department of Veterans Affairs (VA), VACCHCS Fresno Facilities Maintenance Service, requires a contractor to perform a comprehensive repair, calibration and training on Metasys monitoring components in negative pressure rooms and critical areas of the facility. calibrate Metasys system to ensure accuracy of recording and alarming.
Part 3: General Information and Requirements:
Contractor will provide all necessary materials and labor to ensure correct parameters and safe operations are met per manufacturers specifications.
An authorized company capable of providing the required materials, install and testing all components. A lead technician shall be provided by the contractor that has documented experience implementing large scale projects equal to or greater than the scope of this project to oversee all contract personnel.
The contractor shall be fully responsible for compliance with all VA, local, state, and federal environmental/occupational safety laws, rules, and regulations. The contractor shall follow life and safety codes and take necessary actions to avoid conditions that may be hazardous to the health and safety of hospital personnel and patients. The contractor is responsible for meeting all applicable OSHA and VA guidelines for safe working processes; example: lock-out/tag-out program or safe handling of hazardous materials.
All work shall be coordinated with the COR assigned to this project and only commence once approved.
Schedule: Normal work hours will be 8:00am – 4:30 pm Monday-Friday excluding Official Federal Holidays, A contractor is not to work on Official Federal Holidays as listed on OPM.gov(https://www.opm.gov/policy-data-oversight/pay-leave/federal-holidays/#url=Overview). The contractor if they need to perform work over the weekends (Saturdays and Sunday) or outside of work hours above that they will need to request authorization prior too performing any work from the COR/Engineer and final approval from the Contracting Officer. Any request to utility shutdowns must be requested in writing at a minimum of 21 days prior to the requested day of shutdown.
The Government shall be held harmless against any or all loss, cost, damage, claim expense or liability whatsoever, because of accident or injury to persons or property of others occurring in the performance of this contract.
The Contractor shall be responsible for all damages to property, which may be done by him/her or any employee engaged in the performance of this contract.
The parties agree that the Contractor’s personnel working under a contract shall not be considered VA employees for any purpose and shall be considered employees of the contractor. The contractor shall be responsible for providing:
Workers Compensation,
Professional liability insurance,
Health examinations,
Income tax withholding, and
Social Security payments.
Part 4: Detailed Project Scope of Work:
Contractor to calibrate Metasys system in negative pressure rooms in Medical Surgical. This involves air flow, temperature and humidity.
Contractor to calibrate Metasys system in negative pressure rooms in ICU. This involves air flow, temperature and humidity.
Contractor to calibrate Metasys system in negative pressure rooms in Emergency Department. This involves air flow, temperature and humidity.
Contractor to calibrate Metasys system in negative pressure rooms in GI Unit. This involves air flow, temperature and humidity.
Contractor to calibrate Metasys system in negative pressure rooms in morgue. This involves air flow, temperature and humidity.
Contractor to calibrate Metasys system in negative pressure rooms in Pharmacy Cache. This involves air flow, temperature and humidity.
Contractor will calibrate Metasys system in the Operating Room. This involves air flow, temperature and humidity.
Contractor will cal…
Source: SAM.gov, as posted. Verify the current solicitation before responding.
Pursue this opportunity with Mindy
See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.
View the original notice on SAM.gov ↗Similar Active Opportunities (NAICS 334515)
162 ECS Tester Repair - Intent to Sole Source
DEPT OF DEFENSE · Presolicitation · due August 25, 2026
81 EWS Agile Signal Generator RQMT-28674
DEPT OF DEFENSE · Combined Synopsis/Solicitation · due August 25, 2026
DENTCHECK TOOLKIT
DEPT OF DEFENSE · Solicitation · due August 24, 2026
Electronic Test and Measurement Equipment
ENERGY, DEPARTMENT OF · Combined Synopsis/Solicitation · due August 28, 2026
Charleston Generator Monitoring System
DEPT OF DEFENSE · Solicitation · due September 3, 2026
Keysight UXA Signal Analyzer Support
DEPT OF DEFENSE · Combined Synopsis/Solicitation · due August 31, 2026