The Department of Homeland Security is seeking major maintenance and repair services at the U.S. Coast Guard Sector Field Office in Southwest Harbor, ME, under NAICS 236220. This opportunity is set aside for total small businesses, making it suitable for small contractors with relevant experience in glazing and building maintenance. Interested vendors should note that this is a solicitation notice, indicating they will need to prepare a bid rather than simply track the opportunity.
Analysis by Mindy, grounded in the SAM.gov notice.
Description
PART 1 GENERAL
REFERENCES
SECTION 08 81 00
GLAZING
05/19
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)
AAMA 800 (2016) Voluntary Specifications and Test Methods for Sealants
AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)
ANSI Z97.1 (2015) Safety Glazing Materials Used in Buildings - Safety Performance Specifications and Methods of Test
ASTM INTERNATIONAL (ASTM)
ASTM C509 (2006; R 2021) Standard Specification for Elastomeric Cellular Preformed Gasket and Sealing Material
ASTM C864 (2005; R 2015) Dense Elastomeric Compression Seal Gaskets, Setting Blocks, and Spacers
ASTM C920 (2018) Standard Specification for Elastomeric Joint Sealants
ASTM C1021 (2008; R 2014) Standard Practice for Laboratories Engaged in Testing of Building Sealants
ASTM C1036 (2021) Standard Specification for Flat Glass
ASTM C1048 (2018) Standard Specification for
Heat-Strengthened and Fully Tempered Flat Glass
ASTM C1087 (2016) Standard Test Method for Determining Compatibility of
Liquid-Applied Sealants with Accessories Used in Structural Glazing Systems
ASTM C1184 (2023) Standard Specification for Structural Silicone Sealants
ASTM C1281 (2016) Standard Specification for Preformed Tape Sealants for Glazing
Applications
ASTM D395 (2016; E 2017) Standard Test Methods for Rubber Property - Compression Set
ASTM D2287 (2019) Nonrigid Vinyl Chloride Polymer and Copolymer Molding and Extrusion Compounds
ASTM E1300 (2024) Standard Practice for Determining Load Resistance of Glass in Buildings
ASTM E2190 (2010) Standard Specification for Insulating Glass Unit Performance and Evaluation
GLASS ASSOCIATION OF NORTH AMERICA (GANA)
GANA Glazing Manual (2008) Glazing Manual
GANA Sealant Manual (2008) Sealant Manual
GANA Standards Manual (2008) Engineering Standards Manual INSULATING GLASS MANUFACTURERS ALLIANCE (IGMA)
IGMA TB-1200 (1983; R 2016) Guidelines for Insulating Glass Dimensional Tolerances
IGMA TB-3001 (2001) Guidelines for Sloped Glazing
IGMA TM-3000 (1990; R 2016) North American Glazing Guidelines for Sealed Insulating Glass Units for Commercial & Residential Use
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
16 CFR 1201 Safety Standard for Architectural Glazing Materials
SUBMITTALS
Government approval is required for submittals with a "G" or "S" classification. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-03 Product Data Insulating Glass Plastic Glazing Glazing Accessories Sealants
SD-04 Samples
Insulating Glass
Plastic Sheet Glazing Compound Glazing Tape Sealing Tapes
SD-07 Certificates Insulating GlassSD-08 Manufacturer's Instructions Setting and Sealing Materials
Glass Setting
SD-11 Closeout Submittals
Warranty for Insulated Glass Units
SYSTEM DESCRIPTION
Fabricate and install watertight and airtight glazing systems to withstand thermal movement and wind loading without glass breakage, gasket failure, deterioration of glazing accessories, or defects in the work. Glazed panels must comply with the safety standards, in accordance with ANSI Z97.1, and comply with indicated wind/snow loading in accordance with ASTM E1300.
QUALITY CONTROL
Submit two 8 by 10 inch samples of each of the following: tinted glass, patterned glass, heat-absorbing glass, and insulating glass units.
Submit three samples of each other material. Samples of plastic sheets must be minimum 5 by 7 inches.
DELIVERY, STORAGE, AND HANDLING
Deliver products to the site in unopened containers, labeled plainly with manufacturers' names and brands. Store glass and setting materials in safe, enclosed dry locations and do not unpack until needed for installation. Handle and install materials in a manner that will protect them from damage.
ENVIRONMENTAL REQUIREMENTS
Do not start glazing work until the outdoor temperature is above 40 degrees F and rising, unless procedures recommended by the glass manufacturer and approved by the Contracting Officer are made to warm the glass and rabbet surfaces. Provide ventilation to prevent condensation of moisture on glazing work during installation. Do not perform glazing work during damp or rainy weather.
WARRANTY
Warranty for Insulated Glass Units
Warranty insulating glass units against development of material obstruction to vision (such as dust, fogging, or film formation on the inner glass surfaces) caused by failure of the hermetic seal, other than
through glass breakage, for a 10-year period following acceptance of the work. Provide new units for any units failing to comply with terms of this warranty within 45 working days after receipt of notice from the Government.
[][]PART 2 PRODUCTS
GLASS
ASTM C1036, unless specified otherwise. In doors and sidelights, provide safety glazing material conforming to 16 CFR 1201.
Clear Glass
For interior glazing (i.e., pass and observation windows), 1/4 inch thick tempered glass should be used. Type I, Class 1 (clear), Quality q4 (A) .
Provide for glazing openings not indicated or specified otherwise. Use double-strength sheet glass or 1/8 inch float glass for openings up to and including 15 square feet, 3/16 inch for glazing openings over 15 square feet but not over 30 square feet, and 1/4 inch for glazing openings over
30 square feet but not over 45 square feet.
Annealed Glass
Annealed glass must be Type I transparent flat type, Class 1 - clear, Quality q3 - glazing select, 90% percent light transmittance, 1.0 percent shading coefficient, conforming to ASTM C1036.
[]2.1.3 Tempered Glass
ASTM C1048, Kind FT (fully tempered), Condition A (uncoated), Type I, Class 1 (transparent), Quality q3, 3/16" inch thick, 90% percent light transmittance, 1.0 percent shading coefficient conforming to ASTM C1048 and GANA Standards Manual. Color must be clear. Provide wherever safet…