MAJOR MAINTENANCE & REPAIR (M&R) AT USCG SECTOR FIELD OFFICE, SOUTHWEST HARBOR, ME (HANCOCK COUNTY)

HOMELAND SECURITY, DEPARTMENT OF

Notice type
Solicitation
Solicitation #
70Z0G126BSNNEDW01
NAICS
236220
PSC
Z2AZ
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
June 4, 2026
Response due
March 3, 2026
Place of performance
Southwest Harbor, ME

What this opportunity is

The Department of Homeland Security is seeking major maintenance and repair services at the U.S. Coast Guard Sector Field Office in Southwest Harbor, ME, under NAICS 236220. This opportunity is set aside for total small businesses, making it suitable for small contractors with relevant experience in glazing and building maintenance. Interested vendors should note that this is a solicitation notice, indicating they will need to prepare a bid rather than simply track the opportunity.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

PART 1 GENERAL REFERENCES SECTION 08 81 00 GLAZING 05/19 The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) AAMA 800 (2016) Voluntary Specifications and Test Methods for Sealants AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) ANSI Z97.1 (2015) Safety Glazing Materials Used in Buildings - Safety Performance Specifications and Methods of Test ASTM INTERNATIONAL (ASTM) ASTM C509 (2006; R 2021) Standard Specification for Elastomeric Cellular Preformed Gasket and Sealing Material ASTM C864 (2005; R 2015) Dense Elastomeric Compression Seal Gaskets, Setting Blocks, and Spacers ASTM C920 (2018) Standard Specification for Elastomeric Joint Sealants ASTM C1021 (2008; R 2014) Standard Practice for Laboratories Engaged in Testing of Building Sealants ASTM C1036 (2021) Standard Specification for Flat Glass ASTM C1048 (2018) Standard Specification for Heat-Strengthened and Fully Tempered Flat Glass ASTM C1087 (2016) Standard Test Method for Determining Compatibility of Liquid-Applied Sealants with Accessories Used in Structural Glazing Systems ASTM C1184 (2023) Standard Specification for Structural Silicone Sealants ASTM C1281 (2016) Standard Specification for Preformed Tape Sealants for Glazing Applications ASTM D395 (2016; E 2017) Standard Test Methods for Rubber Property - Compression Set ASTM D2287 (2019) Nonrigid Vinyl Chloride Polymer and Copolymer Molding and Extrusion Compounds ASTM E1300 (2024) Standard Practice for Determining Load Resistance of Glass in Buildings ASTM E2190 (2010) Standard Specification for Insulating Glass Unit Performance and Evaluation GLASS ASSOCIATION OF NORTH AMERICA (GANA) GANA Glazing Manual (2008) Glazing Manual GANA Sealant Manual (2008) Sealant Manual GANA Standards Manual (2008) Engineering Standards Manual INSULATING GLASS MANUFACTURERS ALLIANCE (IGMA) IGMA TB-1200 (1983; R 2016) Guidelines for Insulating Glass Dimensional Tolerances IGMA TB-3001 (2001) Guidelines for Sloped Glazing IGMA TM-3000 (1990; R 2016) North American Glazing Guidelines for Sealed Insulating Glass Units for Commercial & Residential Use U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA) 16 CFR 1201 Safety Standard for Architectural Glazing Materials SUBMITTALS Government approval is required for submittals with a "G" or "S" classification. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES: SD-03 Product Data Insulating Glass Plastic Glazing Glazing Accessories Sealants SD-04 Samples Insulating Glass Plastic Sheet Glazing Compound Glazing Tape Sealing Tapes SD-07 Certificates Insulating GlassSD-08 Manufacturer's Instructions Setting and Sealing Materials Glass Setting SD-11 Closeout Submittals Warranty for Insulated Glass Units SYSTEM DESCRIPTION Fabricate and install watertight and airtight glazing systems to withstand thermal movement and wind loading without glass breakage, gasket failure, deterioration of glazing accessories, or defects in the work. Glazed panels must comply with the safety standards, in accordance with ANSI Z97.1, and comply with indicated wind/snow loading in accordance with ASTM E1300. QUALITY CONTROL Submit two 8 by 10 inch samples of each of the following: tinted glass, patterned glass, heat-absorbing glass, and insulating glass units. Submit three samples of each other material. Samples of plastic sheets must be minimum 5 by 7 inches. DELIVERY, STORAGE, AND HANDLING Deliver products to the site in unopened containers, labeled plainly with manufacturers' names and brands. Store glass and setting materials in safe, enclosed dry locations and do not unpack until needed for installation. Handle and install materials in a manner that will protect them from damage. ENVIRONMENTAL REQUIREMENTS Do not start glazing work until the outdoor temperature is above 40 degrees F and rising, unless procedures recommended by the glass manufacturer and approved by the Contracting Officer are made to warm the glass and rabbet surfaces. Provide ventilation to prevent condensation of moisture on glazing work during installation. Do not perform glazing work during damp or rainy weather. WARRANTY Warranty for Insulated Glass Units Warranty insulating glass units against development of material obstruction to vision (such as dust, fogging, or film formation on the inner glass surfaces) caused by failure of the hermetic seal, other than through glass breakage, for a 10-year period following acceptance of the work. Provide new units for any units failing to comply with terms of this warranty within 45 working days after receipt of notice from the Government. [][]PART 2 PRODUCTS GLASS ASTM C1036, unless specified otherwise. In doors and sidelights, provide safety glazing material conforming to 16 CFR 1201. Clear Glass For interior glazing (i.e., pass and observation windows), 1/4 inch thick tempered glass should be used. Type I, Class 1 (clear), Quality q4 (A) . Provide for glazing openings not indicated or specified otherwise. Use double-strength sheet glass or 1/8 inch float glass for openings up to and including 15 square feet, 3/16 inch for glazing openings over 15 square feet but not over 30 square feet, and 1/4 inch for glazing openings over 30 square feet but not over 45 square feet. Annealed Glass Annealed glass must be Type I transparent flat type, Class 1 - clear, Quality q3 - glazing select, 90% percent light transmittance, 1.0 percent shading coefficient, conforming to ASTM C1036. []2.1.3 Tempered Glass ASTM C1048, Kind FT (fully tempered), Condition A (uncoated), Type I, Class 1 (transparent), Quality q3, 3/16" inch thick, 90% percent light transmittance, 1.0 percent shading coefficient conforming to ASTM C1048 and GANA Standards Manual. Color must be clear. Provide wherever safet

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Similar Active Opportunities (NAICS 236220)