MANZ-FIRE SYSTEM INSPECTIONS-BASE YR

INTERIOR, DEPARTMENT OF THE

Notice type
Solicitation
Solicitation #
140P8126Q0038
NAICS
238220
PSC
Y1NZ
Posted
July 2, 2026
Response due
July 16, 2026

What this opportunity is

The Department of the Interior is buying inspection and testing services for fire protection systems at the Manzanar National Historic Site. This solicitation suits businesses classified under NAICS 238220, with no specified set-aside. As a solicitation notice, businesses should prepare to bid rather than simply tracking the opportunity.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

SCOPE OF WORK INSPECTION & TESTING FIRE PROTECTION, DETECTION AND NOTIFICATION SYSTEMS MANZANAR NATIONAL HISTORIC SITE 1 PART 1 – GENERAL INFORMATION A one-year contract with up to 4 option years: Contractor shall provide pricing for base year and for subsequent option years to provide inspection and testing of the following systems and equipment. 1.0 Description of Work: Inspect all identified systems per applicable NFPA Code to ensure code compliance and system functionality, and to identify any deficiencies. The provided National Park Service (NPS) asset specific forms shall be completed for each system inspection, in addition to any NFPA required forms. All completed forms shall be provided post inspection to the Contracting Officer’s Representative in PDF format (see section 3.2). Manzanar National Historic Site (NHS): Perform annual fire inspection for Manzanar NHS, to include the following: • Five (5) dry sprinkler systems • One (1) fire pump (electric powered) • Three (3) hydrants with flow • Six (6) backflow preventers The system is equipped with a test header. 1.1 Location: This project is located in Manzanar NHS, Inyo County, California. All systems are inside or within 1,000 yards of the visitor center building, 5001 US-395, Independence, CA 93526. 1.2 Performance Period: This work shall be provided from approximately July 2026, through July 2027, and the same timelines apply for subsequent option years, if exercised. Annual reports must be reviewed and approved by COR no later than July 1 st each year. 1.3 Regular Working Hours: Regular working hours at the park are from 9:00 a.m. to 4:00 p.m., Monday through Friday, excluding federal holidays. All work shall be scheduled during regular working hours. 1.4 Notification: The Contractor shall notify the Contracting Officer’s Representative at least 72 hours in advance for all work in occupied facilities. 1.5 Work Restrictions: The contractor shall be accompanied by a park employee at all times when performing the work of the contract in occupied park housing units. A park representative will be on-site and available for contractor support (primarily unlocking doors) for non-occupied housing units and public use buildings. 1.6 Qualifications & Experience: The Contractor(s) shall be qualified in the inspection, testing, and repair related to their field of expertise, in full compliance with current NFPA standard’s (i.e. Fire Suppression / Fire Detection & Notification). The Contractor shall have continuously performed inspection and testing in their field of expertise within California for the past three (3) years. The contractor shall hold the appropriate licensure throughout the length of the entire contract. 1.7 Supplies & Services: The Contractor shall provide all manpower, equipment, tools and supplies to perform the requested services, complete and in conformity with the contract. The Contractor shall -- 1 of 4 -- SCOPE OF WORK INSPECTION & TESTING FIRE PROTECTION, DETECTION AND NOTIFICATION SYSTEMS MANZANAR NATIONAL HISTORIC SITE 2 proceed to furnish the services of this contract promptly upon notification by the Contracting Officer (CO). 1.8 Waste Disposal: The Contractor shall legally dispose of all solid waste materials offsite. If applicable, the Contractor shall make provisions for the proper collection, transportation, and off- site disposal of antifreeze solutions and other fluid additives used for flushing during system testing. Disposal of these fluids into the ground, drains, waterways, or park wastewater systems will not be permitted. The Contractor shall dispose of water used for flushing during system testing in a manner that is consistent with the park protocol for disposal of gray water. PART 2 – REFERENCE CODES AND STANDARDS (Revision) The following is a list of NFPA codes and standards that may apply to this scope of work. The Contractor shall use the latest version of the NFPA codes and standards listed below for the inspection, testing, and repair of specified fire protection systems. • NFPA 11 (Standard for Low-, Medium-, and High-Expansion Foam Systems). • NFPA 12 (Standard on Carbon Dioxide Extinguishing Systems). • NFPA 12A (Standard on Halon 1301 Fire Extinguishing Systems). • NFPA 13 (Standard for the Installation of Sprinkler Systems). • NFPA 13D (Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes). • NFPA 13R (Standard for the Installation of Sprinkler Systems in Residential Occupancies up to and Including Four Stories in Height). • NFPA 14 (Standard for the Installation of Standpipes and Hose Systems). • NFPA 15 (Standard for Water Spray Fixed Systems for Fire Protection). • NFPA 16 (Standard for the Installation of Foam-Water Sprinkler and Foam-Water Spray Systems). • NFPA 17 (Standard for Dry Chemical Extinguishing Systems). • NFPA 17A (Standard for Wet Chemical Extinguishing Systems). • NFPA 20 (Standard for the Installation of Stationary Pumps for Fire Protection). • NFPA 22 (Standard for Water Tanks for Private Fire Protection). • NFPA 24 (Standard for the Installation of Private Service Mains and Their Appurtenances). • NFPA 25 (Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems). • NFPA 70 (National Electric Code). • NFPA 72 (National Fire Alarm Code). • NFPA 80 (Standard for Fire Doors and Other Opening Protective’s). • NFPA 90A (Standard for the Installation of Air-Conditioning and Ventilation Systems). • NFPA 96 – (Standard for ventilation Control and Fire Protection of Commercial Cooking Operations). • NFPA 101 (Life Safety Code). • NFPA 110 (Standard for Emergency and Standby Power Systems). • NFPA 291 (Recommended Practice for Fire Flow Testing and Marking of Hydrants). • NFPA 750 (Standard on Water Mist Fire Protection Systems). • NFPA 2001 (Standard on Clean Agent Fire Extinguishing Systems). • NFPA 2010 (Standard for Fixed Aerosol Fire Extingu

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗