Project # 618-26-701 - EHRM - Infrastructure Upgrades - Main Computer Room Update - Minneapolis VAMC - Minneapolis, MN

VETERANS AFFAIRS, DEPARTMENT OF

Notice type
Solicitation
Solicitation #
36C77626B0017
NAICS
236220
PSC
Z2DA
Set-aside
Service-Disabled Veteran-Owned Small Business Set Aside
Posted
June 9, 2026
Response due
July 1, 2026
Place of performance
Minneapolis, MN

What this opportunity is

The Department of Veterans Affairs is seeking contractors for the EHRM Infrastructure Upgrades at the Minneapolis VAMC, specifically focusing on the modernization of the main computer room. This project is set aside for Service-Disabled Veteran-Owned Small Businesses, making it suitable for qualified small firms in this category. Interested vendors should note that the notice type is a solicitation, indicating that they will need to prepare and submit bids to compete for this contract.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

EHRM Infrastructure Upgrades - Minneapolis VAMC - MCR Modernization Project #: 618-26-701 Door Hardware 08 71 00 - 17 INTERIOR SECURITY DOORS INTERIOR SINGLE SECURITY DOORS HW-SH-3F Each [AC, EL, REX, DPS] Door to Have: RATED 1 Continuous Transfer Hinge x INTEGRAL HINGE GUARD CHANNEL X ADJUSTA-SCREWS x 4-THRUWIRE TRANSFER x IN-HINGE ACCESS PANEL 1 Electrified Lock F13-MOD x RIGID OUTSIDE LEVER X NO INSIDE TURN X KEY RETRACTS LATCHBOLT AND DEADBOLT (E01-REX, E06) 24VDC 1 Power Supply Regulated, Filtered, 24VDC, Amperage as required 1 Closer C02011/C020211 1 EL Rim Exit Device ANSI 09 x E01 x E04 1 Auto Door Bottom R0Y346 – HEAVY DUTY 2 Mop Plate 1 Edge Guard (@ Wood Doors) J208M / J211 (VERIFY), CUT: HARDWARE 1 Wall Stop L02101 CONVEX 1 Floor Stop (if wall not available) L02121 x 3 FASTENERS 1 Set Self-Adhesive Seals R0Y154 1 Alarm Contact 120VAC POWER, CONDUIT, AND WIRING BY DIVISION 26. 1 Access Control Reader by Division 28 Door normally closed and locked. Entrance by presenting a valid card to card-reader. Egress allowed at all times. Loss of power maintains security from lock side, entrance by mechanical key only. Door monitored for door ajar and forced open. INTERIOR PAIRS OF SECURITY DOORS HW-SH-9A Each [PB] Pair to Have: [AC, ELR, REX, DPS] Integrated Door to Have: RATED 2 Continuous Transfer Hinge x INTEGRAL HINGE GUARD CHANNEL X ADJUSTA-SCREWS x 4-THRUWIRE TRANSFER x IN-HINGE ACCESS PANEL 1 Electrified Lock F07 (E01-REX, E06) 24VDC 1 Set Auto Flush Bolts TYPE 25 1 Dust Proof Strike L04021 1 Push-button Combination Lock N3 – A156.13 F07 G1 E06 1 Coordinator TYPE 21A 1 Overlapping Astragal with R0Y634 x R0Y154 x THRU-BOLTS Self-Adhesive Seal2 Closers C02011/C02021 4 Armor Plates J101 x 1.275 MM (0.050 INCH) THICKNESS 2 Edge Guard (@ Wood Doors) J208M / J211 (VERIFY), CUT: HARDWARE 2 Overhead Stops C01541-ADJUSTABLE 1 EL Rim Exit Device ANSI 09 x E01 x E04 2 Set Self-Adhesive Seals R0Y154 1 Position Switch Alarm Contact 1 Power Supply Regulated x 24VDC x Amperage As Req'd 1 Access Control Reader by Division 28 1 Auto Door Bottom R0Y346 – HEAVY DUTY -- 1 of 788 -- EHRM Infrastructure Upgrades - Minneapolis VAMC - MCR Modernization Project #: 618-26-701 Door Hardware 08 71 00 - 18 2 Alarm Contacts 120VAC POWER, CONDUIT, AND WIRING BY DIVISION 26 Door normally closed and locked. Entrance by presenting a valid card to card-reader. Egress allowed at all times. Loss of power maintains security from lock side, entrance by mechanical key only. Door monitored for door ajar and forced open. - - - E N D - - - -- 2 of 788 -- EHRM Infrastructure Upgrades - Minneapolis VAMC - MCR Modernization Project #: 618-26-701 Subsurface Preparation for Floor Finishes 09 05 16 - 1 SECTION 09 05 16 SUBSURFACE PREPARATION FOR FLOOR FINISHES PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies subsurface preparation requirements for areas to receive the installation of applied and resinous flooring. This section includes removal of existing floor coverings, testing concrete for moisture and pH, remedial floor coating for concrete floor slabs having Unsatisfactory moisture or pH conditions, floor leveling and repair as required. 1.2 RELATED WORK A. Section 07 92 00, JOINT SEALANTS. 1.3 SUBMITTALS A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA and TEST DATA. B. Written approval confirming product compatibility with subfloor material manufacturer and the flooring manufacturer C. Product Data: 1. Moisture remediation system 2. Underlayment Primer 3. Cementitious Self-Leveling Underlayment 4. Cementitious Trowel-Applied Underlayment (Not suitable for resinous floor finishes) D. Test Data: 1. Moisture test and pH results performed by a qualified independent testing agency or warranty holding manufacturer’s technical representative. 1.4 DELIVERY AND STORAGE A. Deliver materials in containers with labels legible and intact and grade-seals unbroken. B. Store material to prevent damage or contamination. 1.5 APPLICABLE PUBLICATIONS A. Publications listed below form a part of this specification to the extent referenced. Publications are referenced in text by basic designation only. B. ASTM International(ASTM): D638-14(2014) ...................... Standard Test Method for Tensile Properties of Plastics D4259-18(2019) .................... Standard Practice for Preparation of Concrete by Abrasion Prior to Coating Application. C109/C109M-20b(2020) ....... Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. Cube Specimens 7234-19(2020) ....................... Standard Test Method for Pull-Off Adhesion Strength of Coatings on Concrete Using Portable Pull-Off Adhesion Testers C. E96/E96M-16(2016) Standard Test Methods for Water Vapor Transmission of Materials F710-1e1(2020) .................... Standard Practice for Preparing Concrete Floors to Receive Resilient Flooring F1869-16a ............................. Standard Test Method for Measuring Moisture Vapor Emission Rate of Concrete Subfloor Using Anhydrous Calcium Chloride -- 3 of 788 -- EHRM Infrastructure Upgrades - Minneapolis VAMC - MCR Modernization Project #: 618-26-701 Subsurface Preparation for Floor Finishes 09 05 16 - 2 F2170-19a(2020) .................. Standard Test Method for Determining Relative Humidity in Concrete Floor Slabs Using in situ Probes C348-20(2020) ...................... Standard Test Method for Flexural Strength of Hydraulic-Cement Mortars C191-19(2020) ...................... Standard Test Method for Time of Setting of Hydraulic Cement by Vicat Needle PART 2 - PRODUCTS 2.1 MOISTURE REMEDIATION COATING A. System Descriptions: 1. High-solids, epoxy system designed to suppress excess moisture in concrete prior to an overlayment. For use under resinous products, VCT, tile and carpet where issues caused by moisture vapor are a concern. B. Products: Subject to compliance with applicable fire, health, environmental, and safety requirements for storage, handling, installation, and

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Similar Active Opportunities (NAICS 236220)