What this opportunity is
The U.S. Coast Guard is seeking a contractor to perform rear seal leak repairs on the 49406 BUSL, requiring specialized services to address leaks on both main drive engines while the vessel is out of the water. This opportunity is a Partial Small Business Set-Aside, making it suitable for small businesses with relevant technical capabilities and past performance in similar repairs. Interested vendors should note that this is a Combined Synopsis/Solicitation, meaning they must submit quotes via email to the designated contracting officer for consideration.
Analysis by Mindy, grounded in the SAM.gov notice.
Description
COMBINED SYNOPSIS / SOLICITATION & STATEMENT OF WORK
Commercial Services — ANT Moriches 49406 Busl Rear Main Seal Repair
Solicitation Number:
52000PR260025937 (Request For Quote - RFQ)
Agency:
U.S. Coast Guard, Surface Forces Logistics Center (SFLC)
Contract Type:
Firm Fixed Price Purchase Order
Set-Aside Status:
Small Business
1. Combined Synopsis/Solicitation
This is a combined synopsis/solicitation for commercial services, prepared in accordance with the format in subpart 12.6 of the FAR and as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a separate written solicitation will not be issued. This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-87, effective, 7 March 2016. It is anticipated that a competitive price purchase order shall be awarded as a result of this synopsis/solicitation. All responsible sources may submit a quotation, which if timely received, shall be considered by this agency.
1.1 Evaluation Criteria
Quotes will be evaluated based on the following factors:
Technical Capability: The offeror’s ability to perform the services described in the Performance Work Statement/Statement of Work.
Past Performance: The offeror’s record of relevant and recent past performance.
Price: Fair and reasonable pricing.
1.2 Points of Contact
For any questions regarding this solicitation, please contact:
Contracting Officer (KO): Joshua Richardson (Email: Joshua.C.Richardson2@uscg.mil)
COR: Joseph Jenkins (Email: Joseph.a.jenkins@uscg.mil)
1.3 Submission of Quotes
Quotes must be submitted via email to Joshua.C.Richardson2@uscg.mil. The subject line of the email should include the solicitation number: 52000PR260025937 .
2. Statement of Work (SOW)
2.1 Background
This statement of work is intended to outline the repair of both MDE rear main seal leaks on the 49406 BUSL. The small boat has continuous rear main seal leaks on both MDE’s that require repair while vessel is hauled out of water.
2.2 Scope
The rear seal leaks need repair and are outside of unit capabilities, work needs to be done while the vessel is hauled out of the water due to reduction gears needing to be removed.
2.3 Objective
Awarded vendor will provide troubleshooting and repair of leaks on both main rear seals. Vendor is responsible for all tools, supplies and repairs with no assistance from Coast Guard personnel.
2.4 Applicable Documents
Compliance Documents: N/A
Reference Documents: Operation and Maintenance Manual C Series Engines
2.5 Specific Requirements/Tasks
Task One: Troubleshoot Source of Leaks
Troubleshoot issues, verify source of leak, and acquire list of parts and supplies needed to repair issues. The vessel will be located out of the water for the duration of this project, vendor will need to supply its own tools and source of power/lighting for troubleshooting/repairs.
Task Two: Repair Leaks
Fully repair leaks to both engines, will likely include having to move both reduction gears in order to access seals.
3. Contractor Personnel & Project Management
3.1 Qualified Personnel
The Contractor shall provide qualified personnel to perform all requirements specified in this SOW.
3.2 Continuity of Support
The Contractor shall ensure that the contractually required level of support for this requirement is maintained at all times. The Contractor shall ensure that all contract support personnel are present for all hours of the workday. If for any reason the Contractor staffing levels are not maintained due to vacation, leave, appointments, etc., and replacement personnel will not be provided, the Contractor shall provide e-mail notification to the Contracting Officer’s Representative (COR) prior to employee absence. Otherwise, the Contractor shall provide a fully qualified replacement.
3.3 Key Personnel
Before replacing any individual designated as Key by the Government, the Contractor shall notify the Contracting Officer no less than 15 business days in advance, submit written justification for replacement, and provide the name and qualifications of any proposed substitute(s). All proposed substitutes shall possess qualifications equal to or superior to those of the Key person being replaced, unless otherwise approved by the Contracting Officer. The Contractor shall not replace Key Contractor personnel without approval from the Contracting Officer. The following Contractor personnel are designated as Key for this requirement:
Certified Marine Mechanics
Contractor Key personnel shall not be assigned by the Contractor to more than one key position for this requirement.
4. Deliverables & Performance Details
4.1 Deliverables
Report/Service Completion: The contractor shall provide a final report upon completion of services.
Due Date: All services must be completed and deliverables by TBD
4.2 Period of Performance
The period of performance for this contract is from date of award through TBD
4.3 Place of Performance
The primary place of performance will be IPF Boston, 476 Hanover ST Exd, Boston, MA 02109.
4.4 Hours of Operation
Contractor employees shall generally perform all work between the hours of 0700 and 1600 EST, Monday through Friday (except Federal holidays). However, there may be occasions when Contractor employees shall be required to work other than normal business hours, including weekends and holidays, to fulfill requirements under this SOW.
4.5 General Report Requirements
The Contractor shall provide all written reports in electronic format with read/write capability using applications that are compatible with DHS workstations (Windows XP and Microsoft Office Applications).
5. Resources & Invoicing
5.1 Government Furnished Resources
The Governmen…
Source: SAM.gov, as posted. Verify the current solicitation before responding.