SABER IDIQ

DEPT OF DEFENSE

Notice type
Solicitation
Solicitation #
FA486125R0003
NAICS
236220
PSC
Z2JZ
Set-aside
HUBZone Set Aside
Posted
June 11, 2026
Response due
March 19, 2026
Place of performance
Nellis AFB, NV

What this opportunity is

The Department of Defense is seeking a contractor to provide asbestos hazard inspection services at Nellis Air Force Base, specifically for Building 10250. This opportunity is set aside for HUBZone small businesses, making it suitable for those eligible under this designation. The solicitation indicates that contractors should be prepared to interpret the inspection report and identify any potential asbestos hazards, particularly in mechanical rooms, although no asbestos was found in the inspected areas. Interested businesses should track the solicitation closely for bidding opportunities.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

Nellis Air Force Base Asbestos Hazard Inspection Report Building Number: 10250 The information contained in this report pertains only to the specific rooms identified. Macrotec made an effort to identify and inspect each of the building's mechanical rooms, however there may be instances where they may have not been identified or been in high security rooms, etc. Building diagrams were not always provided and when they were, were sometimes out of date. Macrotec also noted if there are suspicions of, or visual evidence of suspect TSI or Surfacing Materials in areas other than the mechanical room, however, Macrotec cannot warrant that there are not additional suspect materials outside of the mechanical rooms identified. Only proper personnel should interpret this report to determine whether the information herein can be utilized. On 8/4/2016, Dustin R McAllister, a certified asbestos inspector for Macrotec Consulting, LLC., performed an inspection to identify the presence or absence of asbestos hazards in the mechanical room(s) of the building. Specifically, Macrotec inspected for the presence of asbestos containing Thermal System Insulation (TSI) and Surfacing Material and made a determination of the condition of these materials, if present. Note that this inspection is not a NESHAP inspection that would identify asbestos containing building materials for the purpose of renovating the rooms or components in the rooms. No asbetos containing TSI or Surfacing Material were found in the mechanical room(s) of building 10250. Please note that these materials and other suspect asbestos containing materials may be present in other areas of the building. Report Limitations: Bldg. 10250 has one mechanical room and one mechanical yard. The mechanical room one black pipe wrap that does not contain asbestos. The mechanical yards has bare pipes and mud on HVAC ducts that was tested and found to not contain asbestos. Building 10250 Inspection Details: Introduction: Office@MacrotecConsulting.com Phone: (702) 949-6225 Fax: (702) 629-5677 -- 1 of 5 -- Mech. Room Investigation Macrotec Project # 16603 Nellis Air Force Base, Bldg. 10250 Appendix A Building 10250 has one mechanical room and one exterior mechanical yard. Above is the mechanical room that has one black pipe wrap that was tested and found to not contain asbestos. The mechanical yard has mud on HVAC duct that was tested and found to not contain asbestos. Above is the another picture of the mechanical room that has bare ducts an bare pipes The mechanical yard has bare pipes. -- 2 of 5 -- Appendix B - Assessment Macrotec Job #16603 - Building 10250 Laboratory reports are attached with this report (if samples were collected). Please note that the primary purpose of this inspection was to determine the presence of TSI or Surfacing Material in the mechanical rooms/areas. Additional suspect asbestos containing TSI or Surfacing Material may be present in other rooms/areas of the building. Mechanical Room One black pipe wrap No ACM Present : Samples Collected : Mechanical Yard Bare pipes and mud on HVAC ducts No ACM Present : Samples Collected : : : : : : : Asbestos Inspection Building 10250 Macrotec Job #16603 Appendix B -- 3 of 5 -- Macrotec Consulting TRIANGLE ENVIRONMENTAL SERVICE CENTER, INC. 13509 East Boundary Road, Suite B, Midlothian, VA 23112 804-739-1751 • fax: 804-739-1753 BULK ASBESTOS SAMPLE ANALYSIS SUMMARY 9724 Mild Weather Ct. Las Vegas, NV 89148 16603-10250 WO #28328 - Bldg. 10250 160809X 08/09/2016 08/10/2016 08/10/2016 B.Trimmer JOB SITE: TESC LOGIN #: DATE OF RECEIPT: DATE OF ANALYSIS: DATE OF REPORT: ANALYST: TESC SAMPLE # CLIENT SAMPLE ID & GROSS DESCRIPTION ESTIMATED % ASBESTOS NON ASBESTOS % FIBERS NON FIBROUS % MATERIALS CLIENT: CLIENT JOB: 100% AB1 / Black foam NAD 1 20% Fiberglass 80% AB2 / Foil, white fibers, gray adhesive NAD 2 Total Samples/Layers Analyzed: 2 August 10, 2016 Page 1 of 1 Samples are analyzed in accordance with “Interim Method for the Determination of Asbestos in Bulk Insulation Samples”, EPA 600/M4-82-020, Dec. 1982 and "Method for the Determination of Asbestos in Bulk Building Materials", EPA 600/R-93/116, July 1993. None Detected: not detected at/or below the detected limit of method (Reporting limit: 1% Asbestos). Glass fiber is analyzed for quality control blank. TESC recommends by point count or Transmission Electron Microscopy (TEM), for materials regulated by the EPA NESHAP (National Emission Standards for Hazardous Air Pollutants) and found to contain less than ten percent (<10%) asbestos by Polarized Light Microscopy (PLM). Both services are available for an additional fee. This report shall not be reproduced, except in full written approval of Triangle Environmental Service Center, Inc. This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. This test report relates only to the item(s) tested. NVLAP Lab Code: 200794-0 LEGEND NAD=No Asbestos Detected, Lino.=Linoleum, JC=Joint Compound] [ Reviewed By Authorized Signatory: Feng Jiang, MS Senior Geologist, Laboratory Director Yuedong Fang, Senior Geologist -- 4 of 5 -- Macrotec Consul , LLC Client Name Nellis Bulk Sampling Chain of Custody Form Project Name Bldg' 7O25O Project Location lrJO #25328 - Bldg. IO2SO Technician _Dus'tin R /llc1llister Laboratorv .rE:;c Stop at 1st pol;itive?: y / N Composite Wall Substrate?: y / N Project Number Collection Date WO Number 7(;603-70250 a/4/2076 ,28325 Turn Around Time Method of Analysis Matrix Eulk 3 DaLl ,PLm Sample # H # lCount Sample Description Material Type : Color / Deserinr sampreto,ffi(General : Room : Soecifie\ 7 2 nE/ nB2 P,'pe l,tttrqp - Black lnterior - //lech Room - N :;ide -_ Exterior - /llech yard - ld side Relinquished By: Relinquished By: ( neceiveo Received By: -- 5 of 5 --

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Similar Active Opportunities (NAICS 236220)