Description
Scope of Work – Solar Lights and East Gate Replacement
Part I. PSNS: Provide & Install New Solar Lights and Light Poles for PSNS Parking Lot (West Side)
The Contractor shall provide all labor, materials, equipment, and supervision to perform the following work:
A. Demolition
Demolish existing concrete or asphalt at each of the ten (10) new light pole base locations.
Excavate holes for the new concrete light pole bases.
All excavated soil is to be collected and disposed of in dumpsters provided by the contractor.
Required equipment for demolition will include, but is not limited to:
Bobcat with attachments
Flatbed truck
Generators
Concrete saw
Jackhammer
Associated hand tools (e.g., grinders, sledgehammers).
B. New Solar-Powered Light Pole Construction in PSNS Parking lot
Provide and install ten (10) steel light poles and ten (10) corresponding concrete bases on the west side of the PSNS parking lot, covering approximately an area of 345 by 230 feet.
The steel light poles will be approximately 18 feet tall, measured from the parking lot grade. The fence post should be domestic schedule 40 pipe 3/16th pipe.
The concrete light pole bases will be 24 inches in diameter and five to six feet (5'-6') deep, with a 30-inch reveal above the finished grade.
Construct the light pole bases by:
Placing concrete forming materials and rebar cages.
Installing forms, bolt templates, and anchor bolts.
Pour new concrete at 4000 PSI.
Removing all concrete forms (including Sonotubes) after curing.
Install two (2) new solar light fixtures at the top of each light pole (20 total), lumens shall be 22,000.
Repair and finish any areas where the existing parking lot surface was removed for the base installation.
All construction debris will be removed from the site prior to project completion.
Required equipment for construction, provided by the contractor, will include but is not limited to:
Bobcat with attachments
Scissor lift
Crane attachment
Associated hand tools (e.g., grinders, drills, trowels, ratchets).
Part II. REMOVE AND REPLACE 12-FOOT-TALL SECURITY PERIMETER FENCING
The Contractor shall provide all labor, materials, equipment, and supervision to perform the following work:
A. Demolition of Existing Fence
Demolish and remove approximately 550 linear feet (LF) of the existing 12-foot-tall, black vinyl-coated chain link perimeter fence. This includes fence fabric, top rail, mid-rail, tension wire, fence ties, brace bands, tension bands, rail ends, fittings, hardware, and posts.
The demolition area will begin where the new fence installation previously ended and continue to the end of the fence line near the east cantilever gate.
An additional section of approximately 60 LF of 15-foot-tall fencing currently installed over the existing turnstiles shall also be removed.
All existing fence posts shall be cut flush with the grade, then torched to a depth of several inches below the concrete surface to allow for new grout coverage.
Demolish and remove one (1) existing pedestrian gate.
Existing grounding lugs shall be carefully removed from the fence posts for reuse during the new construction phase.
All demolished steel and existing barbed wire (from light poles) shall be disposed of in the designated Navy recycling bin.
B. New Fence Construction
Provide and install approximately 550 LF of 12-foot-tall, black vinyl-coated chain link fencing.
Provide and install approximately 60 LF of 15-foot-tall, black vinyl-coated chain link fencing over the existing turnstiles.
The new fence will include a top rail, a mid-rail, and a bottom tension wire.
New fence posts will be sleeved into the existing post footings and secured using high-strength grout (e.g., Quik-Rok or equivalent).
Once set, posts will be marked and cut to the correct height.
The new chain link fabric will be secured to the posts, top rail, and mid-rail using fence ties, and to the bottom tension wire using hog rings. The fabric will be attached to terminal/end posts using tension bands and tension bars.
Provide and install two (2) new 4-foot-wide by 7-foot-tall black vinyl-coated pedestrian gates. One gate will be installed in the same location as the previous pedestrian gate, and a second new gate will be installed in the fence line surrounding the existing fire hydrant.
The existing grounding lugs will be installed onto the new fence posts, which will be drilled and tapped to accommodate them.
Install new 18" stainless steel razor wire around five (5) existing light poles to prevent climbing, attaching it to the top of the fence with hog rings.
All new fence components shall be touched up with matching black spray paint as needed after installation.
Material List: Black Vinyl-Coated Chain Link Fence & Gate
Component
Specifications
Chain Link Fabric
12’ tall, 9-gauge core (8-gauge finish), Black Vinyl Coated
Top/Mid Rail
1-5/8” Diameter, Black Vinyl Coated
Fence Posts
4” Diameter, Black Vinyl Coated
Tension Wire
7-gauge coil spring, Black Vinyl Coated
Eye Tops
4” x 1-5/8”, Black Vinyl Coated
2-Way Brace Bands
4” x 1-5/8”, Black Vinyl Coated
Sleeves
1-5/8” x 6”, Black Vinyl Coated
Tension Bands
4”, Black Vinyl Coated
Brace Bands
4”, Black Vinyl Coated
Single Eye Rail Ends
1-5/8”, Black Vinyl Coated
Post Caps
4”, Black Vinyl Coated
Hog Rings
9-gauge finish, Black Vinyl Coated
Fence Ties
9-gauge finish, Black Vinyl Coated
Tension Bars
12’ x 3/16”, Black Vinyl Coated
Bolts and Nuts
3/8” x 1-1/2”, Galvanized
High Strength Grout
Quik-Rok, Blue Bag High Strength Grout, or equivalent
Gate Frame
1-7/8” Diameter, Black Vinyl Coated
Razor Wire
18” Stainless Steel
Part III. East Sally Port/Entrapment Area and Gates
The Contractor shall provide all labor, materials, equipment, and supervision to perform the following work:
A. Demolition of Existing Fence and Gates
Demolish and remove approximately 200 linear feet (LF) of the existing 12-foot-tall, black vinyl…