What this opportunity is
The Department of Homeland Security is seeking dockside repair services for the USCGC Maple (WLB 207) under a total small business set-aside. This opportunity, classified under NAICS 336611, involves various maintenance tasks including cleaning and inspecting tanks, exhaust piping, and ventilation systems. As a combined synopsis/solicitation notice, interested small businesses should track this opportunity closely and prepare to submit bids in response to the detailed specifications provided. The work will be performed in North Carolina.
Analysis by Mindy, grounded in the SAM.gov notice.
Description
USCGC MAPLE (WLB 207)
SPECIFICATION FOR DOCKSIDE REPAIRS
FY2026
Developed By: Jason W. Taylor
(Rev-0, 23 March 2026)
-- 1 of 186 --
USCGC MAPLE (WLB-225B) DOCKSIDE AVAILABILITY FY2026
ii (Rev-0)
TABLE OF CONTENTS
Revisions Record ......................................................................................................................................... iii
Consolidated List of References ...................................................................................................................iv
Consolidated List of Government-furnished Property .................................................................................ix
Consolidated List of Critical Inspection Items ........................................................................................... xii
Principal Characteristics ............................................................................................................................ xiii
General Requirements ................................................................................................................................... 1
WORK ITEM 1: Fire Prevention Requirements Dockside ......................................................................... 14
WORK ITEM 2: Tanks, Hydraulic Oil Stowage and Service, Clean and Inspect ...................................... 17
WORK ITEM 3: Tanks, Lube Oil, Clean and Inspect ................................................................................ 21
WORK ITEM 4: Hydraulically Operated Cargo Hatch, Inspect and Service ............................................. 25
WORK ITEM 5: Main Diesel Engine, MDE, Exhaust Piping, Commercial Clean .................................... 29
WORK ITEM 6: Ship Service Diesel Generator, SSDG, Exhaust Piping, Commercial Clean .................. 32
WORK ITEM 7: Vent Ducts, Engine and Motor Room, All, Commercial Cleaning ................................. 36
WORK ITEM 8: Vent Ducts, Galley and Pantry Room, All, Commercial Cleaning ................................. 40
WORK ITEM 9: Vent Ducts, Laundry Exhaust, Commercial Cleaning..................................................... 43
WORK ITEM 10: Vent Ducts, All Other, Commercial Cleaning............................................................... 46
WORK ITEM 11: Potable Water Pneumatic Tanks, Clean and Inspect ..................................................... 49
WORK ITEM 12: Compressed Air Receivers and System Valves, All, Clean, Inspect, Hydro and Lift ... 53
WORK ITEM 13: Hull Fittings (Weight Handling Rigging Hardware), Inspect and Test ......................... 59
WORK ITEM 14: Hydraulic Chain Stoppers, Inspect and Service ............................................................ 64
WORK ITEM 15: Crossdeck Winches, Inspect and Service ...................................................................... 68
WORK ITEM 16: Hydraulic Inhaul Winch, Inspect and Service ............................................................... 75
WORK ITEM 17: Mechanical Chain Stoppers, Inspect and Service .......................................................... 85
WORK ITEM 18: Single Point Davit, Inspect and Service ........................................................................ 88
WORK ITEM 19: Welin Lambie Dual Point Davit TWPIV 5.0B, Inspect, Test, and Overhaul ................ 92
WORK ITEM 20: Buoy Crane, Appleton EB600-60-40, Inspect and Service ......................................... 101
WORK ITEM 21: Grey Water Holding Tanks, Clean and Inspect ........................................................... 107
WORK ITEM 22: Sewage Holding Tanks, Clean and Inspect ................................................................. 111
WORK ITEM 23: Tanks (Sewage Holding), Preserve, 100 percent ......................................................... 115
WORK ITEM 24: Pilot House Window Renew ....................................................................................... 118
WORK ITEM 25: Hand Rail Stanchion Renew........................................................................................ 122
WORK ITEM 26: Non-Buoy Weather Deck LED Flood Lights, Replace ............................................... 125
WORK ITEM 27: Compartment Decks, Preserve .................................................................................... 130
WORK ITEM 28: Watertight Deck Penetrations, Renew ......................................................................... 132
WORK ITEM 29: External Deck Drain, Renew ....................................................................................... 136
WORK ITEM 30: Vent Closures, Renew ................................................................................................. 139
WORK ITEM 31: Weather Deck Kickpipes, Renew ................................................................................ 142
WORK ITEM 32: Vent Screens and Louvers, Renew .............................................................................. 150
WORK ITEM 33: Piping Insulation, Renew............................................................................................. 153
WORK ITEM 34: Compartment Insulation Renew .................................................................................. 157
WORK ITEM 35: Deck Covering (Interior Dry/Carpet), Renew ............................................................. 160
WORK ITEM 36: Aft Capstan Control Stand Foundation Repair ............................................................ 163
WORK ITEM 37: Buoy Deck Control Booth Plating Repair ................................................................... 167
WORK ITEM 38: Buoy Port Fairing Repair............................................................................................. 170
-- 2 of 186 --
USCGC MAPLE (WLB-225B) DOCKSIDE AVAILABILITY FY2026
iii (Rev-0)
REVISIONS RECORD
This page is used to record specification revisions, which may have occurred subsequent to a Revision 0 (Rev-0)
package. Information …
Source: SAM.gov, as posted. Verify the current solicitation before responding.