The Department of Veterans Affairs is seeking a contractor to expand pharmacy and radiology facilities in Michigan, classified under NAICS 236220. This solicitation is set aside for Service-Disabled Veteran-Owned Small Businesses, making it suitable for eligible small firms in this category. Interested businesses should note that this is a solicitation notice, indicating they should track the opportunity closely for bidding details rather than simply monitoring for general announcements.
Analysis by Mindy, grounded in the SAM.gov notice.
Description
-- 1 of 2192 --
PAGE INTENTIONALLY LEFT BLANK
-- 2 of 2192 --
10-24
Expand Pharmacy and Radiology 00 01 10-1
DEPARTMENT OF VETERANS AFFAIRS
VHA MASTER SPECIFICATIONS
TABLE OF CONTENTS
Section 00 01 10
DIVISION 00 - SPECIAL SECTIONS DATE
00 01 10 Table of Contents 10-24
00 01 15 List of Drawing Sheets 10-24
00 31 32 Geotechnical Data
Geotechnical Investigation Report 01-21
Geotechnical Investigation Report Supplement 02-21
DIVISION 01 – GENERAL REQUIREMENTS
01 00 00 General Requirements 11-21
01 32 16.15 Project Schedules 11-21
01 33 23 Shop Drawings, Product Data, and Samples 06-21
01 35 26 Safety Requirements 11-21
01 42 19 Reference Standards 11-20
01 45 00 Quality Control 02-21
01 45 29 Testing Laboratory Services 02-23
01 57 19 Temporary Environmental Controls 01-11
01 74 19 Construction Waste Management 11-21
01 91 00 General Commissioning Requirements
Commissioning Plan – Design Phase 10-24
DIVISION 02 – EXISTING CONDITIONS
02 41 00 Demolition 08-17
02 82 13.13 Glovebag Asbestos Abatement
DIVISION 03 – CONCRETE
03 30 00 Cast-In-Place Concrete 11-22
03 35 00 Sealed Concrete Finishing
03 45 00 Precast Architectural Concrete 01-21
DIVISION 04 – MASONRY
04 05 13.02 Mortar for Reinforced Block Masonry 11-22
04 05 16 Grout for Reinforced Block Masonry 11-22
04 21 13 Brick Unit Masonry 08-17
04 22 35 Reinforced Block Masonry 11-22
DIVISION 05 – METALS
05 12 00 Structural Steel Framing 11-22
05 31 00 Steel Decking 11-22
05 36 00 Composite Metal Decking 11-22
05 40 00 Cold Formed Metal Framing 11-22
05 50 00 Metal Fabrications 08-18
DIVISION 06 – WOOD, PLASTICS AND COMPOSITES
06 10 00 Rough Carpentry 10-17
06 20 00 Finish Carpentry 01-21
-- 3 of 2192 --
10-24
Expand Pharmacy and Radiology 00 01 10-2
DIVISION 07 – THERMAL AND MOISTURE PROTECTION
07 13 52 Modified Bituminous Sheet Waterproofing 01-21
07 18 13 Pedestrian Traffic Coatings 01-21
07 21 13 Thermal Insulation 01-21
07 21 63 Fluid-Applied Insulation Coating
07 22 00 Roof and Deck Insulation 01-21
07 27 26 Fluid-Applied Air and Vapor Barrier
07 40 00 Roofing and Siding Panels 01-21
07 53 23 Ethylene-Propylene-Diene-Monomer Roofing 01-21
07 60 00 Flashing and Sheet Metal 01-21
07 71 00 Roof Specialties 01-21
07 81 00 Applied Fireproofing 10-17
07 84 00 Firestopping 01-21
07 92 00 Joint Sealants 10-17
07 95 13 Expansion Joint Cover Assemblies 01-21
DIVISION 08 – OPENINGS
08 11 13 Hollow Metal Doors and Frames 01-21
08 14 00 Interior Wood Doors 01-21
08 31 13 Access Doors and Frames 01-21
08 34 53 Security Doors and Frames 01-21
08 41 13 Aluminum-Framed Entrances and Storefronts 01-21
08 56 20 Pass-Thru Cabinets
08 56 53 Blast Resistant Windows 02-16
08 56 59 Security Windows 01-21
08 71 00 Door Hardware 08-22
08 71 13.11 Low Energy Power Assist Door Operators 01-21
08 80 00 Glazing 01-21
08 87 00 Glazing Surface Films
08 90 00 Louvers and Vents 01-21
DIVISION 09 – FINISHES
09 05 16 Subsurface Preparation for Floor Finishes 01-21
09 06 00 Schedule for Finishes
09 22 16 Non-structural Metal Framing 06-18
09 29 00 Gypsum Board 04-20
09 30 13 Ceramic/Porcelain Tiling 01-21
09 51 00 Acoustical Ceilings 12-18
09 65 13 Resilient Base and Accessories 01-21
09 65 16 Resilient Sheet Flooring 05-18
09 65 19 Resilient Tile Flooring 05-18
09 68 00 Carpeting 01-21
09 91 00 Painting 01-21
09 96 59 Resinous Specialty Glazed Coating Systems for Walls,
Ceilings, Wallboard, and Block CMU
01-21
DIVISION 10 – SPECIALTIES
10 26 00 Wall and Door Protection 01-21
10 26 41 Ballistic Rated Panels
10 28 00 Toilet, Bath and Laundry Accessories 01-21
10 44 13 Fire Extinguisher Cabinets 08-18
10 51 13 Formed Metal Lockers
-- 4 of 2192 --
10-24
Expand Pharmacy and Radiology 00 01 10-3
DIVISION 12 – FURNISHINGS
12 24 00 Window Shades 08-17
12 32 00 Manufactured Wood Casework 01-21
12 36 00 Countertops 12-18
DIVISION 13 – SPECIAL CONSTRUCTION
13 49 26 Modular RFI / EMI Shielding Rooms 10-22
DIVISION 14 – CONVEYING SYSTEM
14 92 00 Pneumatic Tube System Relocation/Modification
DIVISION 21 – FIRE SUPPRESSION
21 13 13 Wet-Pipe Sprinkler Systems 06-15
Fire Pump Report
DIVISION 22 – PLUMBING
22 05 11 Common Work Results for Plumbing 09-20
22 05 12 General Motor Requirements for Plumbing Equipment 09-20
22 05 19 Meters and Gages for Plumbing Piping 09-20
22 05 23 General-Duty Valves for Plumbing Piping 09-20
22 07 11 Plumbing Insulation 09-19
22 08 00 Commissioning of Plumbing Systems 11-16
22 11 00 Facility Water Distribution 05-21
22 13 00 Facility Sanitary and Vent Piping 09-20
22 14 00 Facility Storm Drainage 09-15
22 14 29 Sump Pumps 09-15
22 15 00 Compressed-Air Systems 09-20
22 40 00 Plumbing Fixtures 09-15
22 62 00 Vacuum Systems for Healthcare Facilities 09-15
22 63 00 Gas Systems for Healthcare Facilities 09-15
DIVISION 23 – HEATING, VENTILATING, AND AIR
CONDITIONING (HVAC)
23 01 30.51 HVAC Air Duct Cleaning
23 05 11 Common Work Results for HVAC 02-20
23 05 12 General Motor Requirements for HVAC and Steam
Generation Equipment
02-20
23 05 14 Variable Frequency Drives
23 05 41 Noise and Vibration Control for HVAC Piping & Equipment 02-20
23 05 93 Testing, Adjusting, and Balancing for HVAC 02-20
23 07 11 HVAC and Boiler Plant Insulation 02-20
23 08 00 Commissioning of HVAC Systems 02-20
23 09 23 Direct-Digital Control System for HVAC 08-20
23 09 93 Sequence of Operation for HVAC Controls
23 21 13 Hydronic Piping 02-20
23 22 13 Steam and Condensate Heating Piping 02-20
23 25 00 HVAC Water Treatment 02-20
23 31 00 HVAC Ducts and Casings 02-20
23 34 00 HVAC Fans 02-20
23 36 00 Air Terminal Units 02-20
23 37 00 Air Outlets and Inlets 02-20
-- 5 of 2192 --
10-24
Expand Pharmacy and Radiology 00 01 10-4
23 40 00 HVAC Air Cleaning Devices 03-20
23 73 00 Indoor Central-Station Air-Handling Units 03-20
23 81 23 Computer Room Air Conditioners 03-20
23 82…