What this opportunity is

The Department of Defense is seeking a Toshiba brand 150 HP electric motor, specifically model B1504YLF4USH, suitable for use in hazardous environments. This opportunity is set aside for small businesses, making it ideal for those specializing in industrial electrical equipment. Interested vendors should note that this is a combined synopsis/solicitation notice, indicating they should track the opportunity closely and prepare to submit bids in response to the solicitation.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

Item: Electric motor Brand Name: Toshiba Part Number: B1504YLF4USH Salient Characteristics: Manufacturer Toshiba Model / Part Number B1504YLF4USHFrame Size NEMA 445T Enclosure Type Totally Enclosed Fan Cooled (TEFC) / Totally Enclosed Explosion Proof (TEXP) Mounting Configuration Footed Mount / Rigid Base Construction Material Rugged Cast Iron (Frame, End Brackets, Conduit Box, and Fan Cover) Physical Dimensions Height: ~26 in, Length: ~48.4 in, Width: ~22.4 in Estimated Net Weight ~2,087 lbs. . Electrical and Performance Characteristics These performance metrics ensure compatibility with tactical or base electrical systems . Salient Characteristic Required Specification Output Power 150 HP (Horsepower) Synchronous Speed 1800RPM (Revolutions Per Minute) Operating Voltage Dual-rated 230 / 460 VAC Phase /Frequency 3-Phase, 60 Hz Service Factor 1.15 Nominal Full Load Efficiency 95.8%(NEMA Premium Efficiency compliant) Full Load Amperage 352 A (at 230V) / 176 A (at460V) Duty Cycle Continuous .. Environmental and Safety Ratings Due to the critical nature of Department of War missions and operations in hazardous areas, the motor must carry verified explosion-proof ratings to handle volatile elements. Salient Characteristic Required Specification Hazardous Environment Certifications Must be certified for: Class I, Division 1, Group D (Flammable Gases) Class II, Division 1, Groups E, F and G(Combustible Dusts) Temperature Code Rating T3C (160C maximum exterior surface temperature under fault conditions) Standards Compliance Exceeds UL and CSA safety standards for hazardous environments1 each

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Similar Active Opportunities (NAICS 335312)