15340 - Mezzanine & Modular Office

DEPT OF DEFENSE

Notice type
Combined Synopsis/Solicitation
Solicitation #
FA8227-26-A-1002
NAICS
236210
PSC
Y1GZ
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
July 17, 2026
Response due
August 3, 2026
Place of performance
Hill Air Force Base, UT

What this opportunity is

The Department of Defense is seeking a contractor for the design and construction of a 1,200 square foot mezzanine in Building 238, South Center, Utah. This opportunity is set aside for total small businesses under NAICS 236210, making it suitable for small construction firms with experience in design and structural work. The notice type is a Combined Synopsis/Solicitation, indicating that interested businesses should track the opportunity closely and prepare to submit bids as detailed specifications are provided.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

Statement of Work: Mezzanine Construction Project Design and Construction of a 1200 sq. ft. Mezzanine in Building 238, South Center 1.0 Project Overview & Summary This Statement of Work outlines the requirements for the design and construction of a new 1200 square foot (30’ x 40’) enclosed mezzanine to be located in the South Center section of Building 238. The scope of this project includes the construction of a new mezzanine and stairs with a fully enclosed space featuring an office, a break room, and a multi-purpose area designated for use as both a computer lab and a general meeting space. The project encompasses all associated structural, electrical/lighting, data, and fire alarm/suppression systems. Careful consideration must be given to the placement of support columns to maximize usable workspace and allow for general repair work and tool box storage on the ground floor. All work must adhere to applicable life safety and building codes. 2.0 Scope of Work The contractor shall provide all labor, materials, and equipment necessary to perform the following: • Design: Provide a complete design package for the new mezzanine, adhering to all specified codes and standards. The design should prioritize a maximum of nine (9) support columns and avoid new footings where possible. If this approach is not feasible or is cost-prohibitive, a reasonable alternative or a dual-option proposal is required. • Construction: Fabricate and erect the new mezzanine steel structure and decking and stairs. • Enclosure: Frame and finish all walls and the ceiling for the upper level. -- 1 of 4 -- • Interior Finishes: Install flooring, cabinetry, and other specified finishes. • Utilities: Install all required systems, electrical, data, and lighting for both the upper mezzanine level and the area below. Coordinate with the customer for plumbing hookups (accomplished by customer). • Safety Systems: Integrate fire alarm and suppression systems as required by code. • Contractor will be able to use caged area to stage materials where the mezzanine is needing to be built. 3.0 Technical Specifications Category Requirement Details Structure Dimensions & Location 30’ x 40’ mezzanine located in the south-center portion of Building 238. Support Columns Design for a maximum of nine (9) columns, bolted to the existing concrete slab. No new footings are preferred. Clear Height (Below) A minimum of 11'0" clear height from the ground floor to the underside of the mezzanine. Load Bearing The structure and stairs must be rated for its intended office/assembly occupancy and meet all applicable facility codes. Paint All steel components are to be painted light grey using a durable, industrial-grade primer and paint. Interior Finishes Flooring Main Area/Office: Carpet tiles. Break Room: LVP (Luxury Vinyl Plank) wood planks and rubber wall base in all areas. (Contractor to provide options for customer selection.) -- 2 of 4 -- Electrical & Data Data Install data runs to all designated computer locations within the multi-purpose area and office. Break Room Circuits Provide three (3) dedicated circuits/receptacles for refrigerators. Provide four (4) dedicated circuits for microwaves with receptacles at appropriate counter height. Plumbing Scope & Coordination The contractor shall stub out plumbing supply and drain lines. The final installation and connection will be performed by the customer. The design must ensure customer can meet all plumbing codes. Break Room Fixtures Rough in plumbing for double sink basin. Lighting Type & Standards All lighting shall be LED with Dimmer switches and meet applicable standards for brightness. The proposal must include designed Lumen counts for each area. Locations Install lighting fixtures on the enclosed upper level and on the underside of the mezzanine to illuminate the ground-level workshop area. 4.0 Codes and Standards Compliance All design and construction work must conform to the latest editions of the following: • Unified Facility Criteria (UFC) • Hill Air Force Base Facility Design Standards • All applicable local and national building, electrical, plumbing, mechanical, and fire safety codes. -- 3 of 4 -- -- 4 of 4 --

Source: SAM.gov, as posted. Verify the current solicitation before responding.