52000QR260026976- CGC Earl Cunningham and CGC Frederick Mann Underwater Hull Inspect, Clean & Zinc Renewal

HOMELAND SECURITY, DEPARTMENT OF

Notice type
Combined Synopsis/Solicitation
Solicitation #
52000QR260026976
NAICS
336611
PSC
J020
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
July 24, 2026
Response due
August 3, 2026
Place of performance
Kodiak, AK

What this opportunity is

The Department of Homeland Security is soliciting a Total Small Business Set-Aside for underwater hull inspection, cleaning, and zinc renewal services for the Coast Guard cutters CGC Earl Cunningham and CGC Frederick Mann. The work must be completed between August 10-14, 2026, for the Earl Cunningham and August 17-21, 2026, for the Frederick Mann, at USCG Base Kodiak in Kodiak, AK. The notice type is a Combined Synopsis/Solicitation, which means interested parties should track the solicitation for updates rather than submitting a bid immediately.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

Statement of Work (SOW) For Underwater Hull Inspect, Clean & Zinc Renewal 1. Background and Current Observed Issues CGC Earl Cunningham & CGC Frederick Mann are requesting underwater hull inspection, cleaning and zinc renewal. 2. REFERENCES CG MPC B10015.D, UNDERWATER BODY (DIVER), INSP/CLN CG MPC B10018.D, UNDERWATER ZINC ANODES, REPLACE 3. REQUIREMENTS Entity completing the work must have trained personnel. The diver must have a dive tender aboard the vessel during dive operations. Hull must be thoroughly cleaned IAW MPC B10015.D and all pre & post cleaning forms must be completed. Zincs must be renewed IAW MPC B10018.D. There are 12 additional stern tube zincs not identified in the current B10018.D maintenance procedure card. 4. PERIOD OF PERFORMANCE This maintenance must be completed between: a. EARL CUNNINGHAM 10 - 14 August, 2026. b. FREDERICK MANN 17 - 21 August, 2026 5. PLACE OF PERFORMANCE USCG Base Kodiak 614 Seafarer Dr Kodiak, AK 99619 6. POINTS OF CONTACT a. Cutter: EMC Samuel Donahue Teams: (207) 577-8492 Email: Samuel.m.donahue@uscg.mil b. Norfolk, VA Office: Contracting Officer Technical Representative (COR): LTJG Tanner Miller Teams: (571) 610-4597 Email: Tanner.m.miller@uscg.mil -- 1 of 16 -- STATEMENT OF WORK CGC EARL CUNNINGHAM AND CGC FREDERICK MANN DIVE Hull Plating, U/W Body, Diver’s Inspect, Clean and Renew U/W Zinc Anodes Perform 1. SCOPE 1.1 Intent. This work item describes the requirements for the Contractor to conduct an inspection and cleaning of the vessel’s U/W body and renew U/W zinc anodes while the vessel is moored pier side. Affected surfaces or components include, but are not limited to the following: • U/W hull plating. • U/W body coating system. • Transducer(s)/sonar dome. • Drive Systems • Appendages • Cathodic Protection 1.2 Government-furnished property. MTI ITEM DESCRIPTION NSN/PN QTY N Anode, B/T Gear Case P/N: 1081226, NIIN: 015485655 1 N Anode, B/T Tunnel P/N: 2002416, NIIN: 015664112 12 N Anode, Sea Chest Grate P/N: GA-4, NIIN: 016476179 4 N Anode, Stern Tube P/N: Z0020202H3 REV. 0, NIIN: 016445483 28 N Nut, Self-Locking, P/N: 90715A145, NIIN: 015085774 52 N Screw, Prop Zinc Plate P/N: 950756, NIIN: 016340210 8 N Screw, Sea Chest Grate Anode P/N: 93190A634, NIIN: 016197182 4 N Screw, Stern Tube Covers P/N: 90585A626, NIIN: 016161107 44 N Zinc Plate, Propeller P/N: 950733, NIIN: 016278941 2 2. REFERENCES Coast Guard Maintenance Procedure Card (MPC) B10015.D, UNDERWATER BODY (DIVER), INSP/CLN Coast Guard Maintenance Procedure Card (MPC) B10018.D, UNDERWATER ZINC ANODES, REPLACE COAST GUARD DRAWINGS Coast Guard Drawing 154 WPC 633-301, Rev C, Cathodic Protection System COAST GUARD PUBLICATIONS Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2020, General Requirements -- 2 of 16 -- STATEMENT OF WORK CGC EARL CUNNINGHAM AND CGC FREDERICK MANN DIVE OTHER REFERENCES Code of Federal Regulations (CFR) Title 29, Part 1910, Subpart T, 2007, Commercial Diving Operations 3. REQUIREMENTS 3.1 General. 3.1.1 CIR. None. 3.1.2 Tech Rep. Not Applicable. 3.1.3 Protective measures. The Contractor must furnish and install all protective measures in accordance with SFLC Std Spec 0000, paragraph 3.3.3 (Vessel component, space, and equipment protection). 3.1.4 Interferences. The Contractor must handle all interferences in accordance with SFLC Std Spec 0000, paragraph 3.3.5 (Interferences). 3.1.5 The Contractor must provide the Coast Guard Inspector 24 hours advance notice of when the diver inspection will occur. Before diving procedures are commenced, meet with the COR and the Coast Guard Inspector, to discuss diving safety requirements and the securing of cutter machinery, as applicable. 3.2 Pre-diving clearance. The Contractor must ensure that the diving team must obtain clearance from the Officer-of-the-Deck before beginning diving operations. Ensure the Coast Guard Inspector has capability for maintaining continuous two-way communication with diving personnel at all times, during the performance of the this work item. 3.2.1 The Contractor must, in accordance with 29 CFR 1910.401-440, provide a certified diver and a tender team, as well as necessary support personnel and equipment, to accomplish the tasks specified herein. 3.3 Inspection requirements - general. The Contractor must survey the entire U/W body of the vessel in accordance with MPC B10015.D, to inspect for abnormal conditions or situations, which may include, but not be limited to the below-listed. The Contractor must use the drawings and MPC’s listed in the References Section for guidance and accomplish the following tasks. NOTE At Contractor’s request, Ship’s force will secure and tag out the cathodic protection system, main engines, steering gear, generator set, A/C unit, fire pumps, and all other machinery which may cause a hazard while a diver is in the water IAW COMDTINST 9077.1, MPC B10015.D and MPC B10018.D. WARNING Mixed gas diving and live boating are not permitted. -- 3 of 16 -- STATEMENT OF WORK CGC EARL CUNNINGHAM AND CGC FREDERICK MANN DIVE • Hull plating and appendage damages. • Coating system defects or failures. • Welding corrosion and erosion. • Deformation in appendages. • Zinc performance. 3.3.1 Hull plating. The Contractor must inspect the exterior condition of the hull in accordance with MPC B10015.D for presence of marine growth, deformation, and any evidence of major corrosion or electrolytic action. Inspect for deformation along the stem and keel areas, condition of butt-welded seams, doubler plates, lap seams, and any signs of damaged plating or unusual waviness in the plating. 3.3.2 Coating system inspection. The Contractor must inspect the condition of the U/W body coating system, for signs of the following: • Peeling. • Blistering. • Abrasion. 3.3.2.1 Use the guidelines provided in Table I (Paint Deterioration Ratings (PDR) for Antifouling/Anticorrosion (AF/AC) Paint System) and Table 2 (Fouling

Source: SAM.gov, as posted. Verify the current solicitation before responding.