56--BFO FENCING PROJECT-FALXA/IBERLIN

INTERIOR, DEPARTMENT OF THE

Notice type
Combined Synopsis/Solicitation
Solicitation #
140L6226Q0014
NAICS
238990
PSC
5660
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
June 17, 2026
Response due
June 26, 2026

Description

Questions and Answers Question 1: Should the posts supporting the metal vehicle gates use stronger tubular pipe than 2 3/8-inch diameter pipe? Answer 1: Yes. The tubular pipe should be a minimum of 7-inch outside diameter and 20 lb/ft weight, set a minimum of 48 inches in depth. Question 2: End panels in the wide gully bottoms are subject to wash out; would another design be appropriate? Answer 2: Yes. As identified in the SOW, a 4-wire “break-away” gate across the gulley bottom with stress panels starting up the slope of each draw may be constructed. A suspended swinging flood gate design is also acceptable, consisting of a cable strung between the stress panels on both sides of the gulley top with suspended hanging pipes and spacers between the pipes.

Source: SAM.gov, as posted. Verify the current solicitation before responding.