Eareckson Air Station Container Tower

DEPT OF DEFENSE

Notice type
Combined Synopsis/Solicitation
Solicitation #
FA521526Q0112
NAICS
237130
PSC
Y1PZ
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
July 21, 2026
Response due
July 25, 2026
Place of performance
EARECKSON AS, AK

Description

-- 1 of 19 -- -- 2 of 19 -- -- 3 of 19 -- REV: DWN: ENG'R: DRAWING NO: DATE: CHK'D: DESCRIPTION REV. FILE NO. REVISIONS DWN PRODUCTS LLC PEORIA, IL 61601-5999 TOLL FREE 800-727-ROHN PO BOX 5999 THIS DRAWING IS THE PROPERTY OF ROHN. IT IS NOT TO BE REPRODUCED, COPIED OR TRACED IN WHOLE OR IN PART WITHOUT OUR WRITTEN CONSENT. CHK APP SHEET #: PRJ. ENG'R: PRJ. MANG'R: R JHY JDM SY FM060 PRE-INSTALLATION INSPECTION FORM NUMBER: FM060 09/03/2019 ROHN 3 1 OF 1 DATE: 3 ADDED NOTES 1 THROUGH 5 03/18/2024 SY JDM JHY WE APPRECIATE YOUR FEEDBACK! PLEASE TAKE OUR 2 MINUTE SURVEY TO HELP US IMPROVE! PRE-INSTALLATION INSPECTION THANK YOU FOR THE PURCHASE OF YOUR ROHN PRODUCT. WE ARE EXCITED THAT YOU CHOOSE ROHN TO SUPPLY YOU WITH A QUALITY PRODUCT. IN ORDER TO COMMUNICATE EFFECTIVELY, ELIMINATE ERRORS AND PROVIDE A SMOOTH INSTALLATION EXPERIENCE, IT IS IMPORTANT FOR THE INSTALLER TO PERFORM A PRE-INSTALLATION INSPECTION OF ALL COMPONENTS/PARTS ASSOCIATED WITH YOUR ORDER. PRIOR TO THE INSTALLATION, THE FOLLOWING INSPECTIONS ARE REQUIRED: 1. ROHN WILL SHIP MONOPOLES AND TOWERS ON DEDICATED FLATBED TRAILERS. THE CARRIER'S DRIVER WILL DETERMINE WHETHER THE SITE IS ACCESSIBLE FOR DELIVERY. IF THE DRIVER DETERMINES THAT IT IS IMPOSSIBLE TO REACH THE SITE WITHOUT DAMAGING THE MATERIAL, TRUCK OR TRAILER, THE BUYER IS RESPONSIBLE FOR FINDING AN ALTERNATIVE SITE FOR UNLOADING. ROHN DOES NOT ASSUME LIABILITY FOR COSTS INCURRED BY THE BUYER BECAUSE OF DELAYED DELIVERY BEYOND THE CONTROL OF ROHN. 2. PRIOR TO UNLOADING THE CARRIER, THE CREW MUST VISUALLY INSPECT THE PRODUCT FOR ANY DAMAGES THAT MAY HAVE OCCURRED DURING SHIPMENT. DAMAGES THAT ARE NOT NOTED BY THE CREW ON ROHN'S BILL OF LADING BEFORE SIGNING IT WILL BE THE BUYER'S RESPONSIBILITY. 3. AFTER UNLOADING THE MATERIAL, THE CREW MUST INVENTORY THE MATERIAL AGAINST THE BILL OF MATERIAL PROVIDED BY ROHN AND MAKE ALL CLAIMS FOR SHORTAGES WITHIN 48 HOURS OF DELIVERY. ROHN WILL NOT BE RESPONSIBLE FOR CLAIMS MADE AFTER 48 HOURS FROM DELIVERY. 4. THE CREW WILL HAVE 2 HOURS FROM THE ARRIVAL TIME TO UNLOAD THE SHIPMENT. IF THE CARRIER IS DELAYED LONGER THAN 2 HOURS, AN ADDITIONAL FREIGHT CHARGE MAY APPLY. 5. ADDITIONAL FREIGHT CHARGES MAY BE INCURRED IF THE DELIVERY ADDRESS OR DATE IS CHANGED DURING MID-DELIVERY. 6. IF THERE ARE PARTS THAT ARE FABRICATED INCORRECTLY AND THE PARTS WERE NOT EASILY DETECTABLE DURING THE PRE-INSTALLATION INSPECTION, ROHN MUST BE NOTIFIED IMMEDIATELY UPON IDENTIFICATION OF THE PARTS. IN ADDITION, PICTURES MUST BE TAKEN OF THE ISSUES AND SENT TO ROHN IMMEDIATELY. 7. IT IS IMPORTANT TO VERIFY THE ASSEMBLY DRAWINGS AND ANCHOR ROD LAYOUT DRAWINGS ARE RECEIVED WITH THE DELIVERY, WHEN ANCHOR RODS ARE TO BE INSTALLED. IN ADDITION, IT IS IMPORTANT TO VERIFY THE ANCHOR ROD TEMPLATE PART NUMBERS MATCH THE DESIGNATED PART NUMBERS ON THE ANCHOR ROD LAYOUT DRAWING. IF THERE ARE DISCREPANCIES, NOTIFY ROHN IMMEDIATELY. ROHN WILL NOT BE RESPONSIBLE FOR CHARGES ASSOCIATED WITH INSTALLING THE WRONG SIZE ANCHOR RODS, THE WRONG NUMBER OF ANCHOR RODS OR THE INCORRECT ANCHOR ROD ORIENTATION. 8. TRIAL ASSEMBLY OF COMPONENTS ON LEVEL GROUND IS RECOMMENDED PRIOR TO ERECTION TO DETERMINE THE PROPER ASSEMBLY SEQUENCE. 9. IF PART SHORTAGES OR DAMAGED MATERIAL ARE FOUND, ROHN MUST BE NOTIFIED IMMEDIATELY TO ALLOW ROHN TIME TO REPAIR OR EXPEDITE NEW PARTS/MATERIALS TO THE JOB SITE. 10. INDIVIDUAL BOLT ORIENTATION (NUT UP OR DOWN) IS DISCRETIONARY UNLESS OTHERWISE NOTED. 11. ROHN WILL NOT BE RESPONSIBLE FOR EXCESS CHARGES INCLUDING CRANE CHARGES, DRILLING RIG CHARGES, EQUIPMENT CHARGES, CREW CHARGES AND MOBILIZATION CHARGES. 12. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT THE APPROPRIATE ROHN SALES REP/MANAGER AT (309) 566-3000. -- 4 of 19 -- REV: DWN: ENG'R: DRAWING NO: DATE: CHK'D: DESCRIPTION REV. FILE NO. REVISIONS DWN PRODUCTS LLC PEORIA, IL 61601-5999 TOLL FREE 800-727-ROHN PO BOX 5999 THIS DRAWING IS THE PROPERTY OF ROHN. IT IS NOT TO BE REPRODUCED, COPIED OR TRACED IN WHOLE OR IN PART WITHOUT OUR WRITTEN CONSENT. CHK APP SHEET #: PRJ. ENG'R: PRJ. MANG'R: R OH GHB TWS A790135 ROHN STANDARD BOLT ASSEMBLY INSTALLATIONS 07/05/1979 9 1 OF 2 ROHN STANDARD BOLT ASSEMBLIES 1. ALL BOLTED CONNECTIONS ARE SNUG TIGHT CONNECTIONS UNLESS PRESTRESSED BOLTS ARE INDICATED ON AN ASSEMBLY DRAWING. 2. ROHN STANDARD BOLT ASSEMBLIES ARE ILLUSTRATED ON THE ADJACENT INSTALLATION DETAILS. WHEN SPECIFIED BY THE PURCHASER, OPTIONAL NUT-LOCKING DEVICES (TRI-LOC NUTS, ANCO NUTS, OR LOCK WASHERS) ARE PROVIDED AS A SUBSTITUTE FOR PAL NUTS FOR SNUG TIGHT CONNECTIONS (REFER TO SHEET 2 FOR INSTALLATION DETAILS). 3. TRI-LOC NUTS ARE PROVIDED AS STANDARD NUT-LOCKING DEVICES FOR SNUG TIGHT BOLTS GREATER THAN 1 INCH DIAMETER. ANCO NUTS ARE SUBSTITUTED FOR TRI-LOC NUTS WHEN SPECIFIED BY THE PURCHASER. 4. PRETENSIONED BOLTS ARE PROVIDED AS AN ASSEMBLY INCLUDING THE BOLT, NUT AND REQUIRED WASHERS AND ARE TO BE USED, UNLESS OTHERWISE NOTED, FOR ALL DOUBLE ANGLE CONNECTIONS AND OTHER CONNECTIONS NOTED ON AN ASSEMBLY DRAWING. A NUT-LOCKING DEVICE IS NOT REQUIRED OR PROVIDED FOR PRETENSIONED BOLT ASSEMBLIES. WASHERS 5. WASHERS ARE PROVIDED TO COVER ALL OVERSIZED HOLES AND EXPOSED SLOTS. WHEN AN OVERSIZED HOLE OR EXPOSED SLOT IS PRESENT ON BOTH SIDES OF A CONNECTION, A WASHER IS REQUIRED UNDER THE BOLT HEAD AND THE NUT AND THE BOLT ASSEMBLY SUFFIX IN THE ASSEMBLY DRAWING BOM WILL INCLUDE AN ADDITIONAL “W”. 6. WASHERS ARE ALSO PROVIDED TO INCREASE THE GRIP THICKNESS WHEN REQUIRED TO PREVENT THE NUT FROM BOTTOMING OUT ON THE BOLT THREADS. 7. FOR SLOTTED GUSSET PLATE CONNECTIONS, WASHERS ARE ONLY REQUIRED FOR SINGLE ANGLE MEMBERS (SLOT EXPOSED ON ONE SIDE). WASHERS ARE NOT REQUIRED OR PROVIDED FOR DOUBLE ANGLE CONNECTIONS (SLOT IS NOT EXPOSED). SNUG TIGHT BOLT ASSEMBLY INSTALLATION 8. UNLESS OTHERWISE NOTED, BOLT ASSEMBLIES ARE TO BE TIGHTENED TO A SNUG TIGHT CONDITION (MEMBERS IN FIRM CONTACT USING AN ORDINARY WRENCH OR IMPACT WRENCH) AND SHALL INCLUDE A NUT-LOCKING DEVICE. 9.

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Similar Active Opportunities (NAICS 237130)