What this opportunity is
The Department of Defense is seeking a contractor to install a Lateral Filing System at Fairchild Air Force Base in Washington, under a total small business set-aside. The project involves providing new equipment, ensuring operational capability, and disposing of debris according to regulations. This solicitation is suitable for small businesses capable of meeting brand name or equal specifications and passing security requirements for personnel access. Interested vendors should track this notice for further details and requirements.
Analysis by Mindy, grounded in the SAM.gov notice.
Description
STATEMENT OF WORK
for
FY26 SFS LATERAL FILING SYSTEM
February 2026
FA462026QA218
Attachment 1 - Statement of Work
1 of 3
-- 1 of 3 --
Statement of Work (SOW)
for
FY26 SFS Lateral Filing System
Fairchild AFB, WA
1. BACKGROUND: Fairchild Air Force Base maximizes space utilization through the use of lateral
filing systems. This effective method of storing supplies allows for efficient utilization of space and ease
of retrieval.
2. SCOPE OF WORK: The Contractor shall furnish new lateral filing system, test for operational
capability and disposal of any debris/waste in accordance with all state, local, and federal guidelines and
regulations.
3. OBJECTIVES: Ensure efficient supplies, records and materials storage and handling.
4. REQUIREMENTS: BRAND NAME OR EQUAL Parts numbers and salient characteristics is
specified by CLIN within Appendix A. All parts provided shall be new. No refurbished materials will be
accepted. Standard manufacturer warranties on parts and labor rates shall apply.
5. SECURITY REQUIREMENTS: All personnel employed by the Contractor in the performance of
this contract, or any representative of the Contractor entering the government installation, shall abide by
all Fairchild Air Force Base security regulations. Personnel performing the work requested will be
escorted for the duration on the installation. Individuals must be able to pass a background check that will
be conducted prior to entry of the installation. Individuals performing the work will be required to provide
their full name, DOB, SSN, driver’s license issuing state and license number to gain access to the
installation.
6. PLACE OF PERFORMANCE: All work will be performed on Fairchild Air Force Base in the
buildings/locations specified in the appendices and by CLIN.
7. APPENDIX:
Appendix A: CLIN 0001
FA462026QA218
Attachment 1 - Statement of Work
2 of 3
-- 2 of 3 --
Appendix A: CLIN 0001
BRAND NAME OR
EQUAL
Part Number Item Description Qty
MEG 125-1311S VCM Kardex Megamat 125 VCM 1
Salient Characteristics:
1. Each unit shall have overall dimensions of 90.56” H (+/- 1”) x 103.54” W (+/- 1”) x
47.32" D (+12” Including Work Counter) (+/- 1”)
2. Each unit shall include 13 Lateral Carriers with drawers for filing Top Tab Folders.
3. Unit shall Include standard manufacturer 2-year parts and labor warranty.
4. Unit shall provide a manual drive crank capable of moving the carriers in case of electric
outage for easy access to content within the unit.
5. Units will come with a fixed standing position posting board at 39.4” high with light
gray finish.
6. Unit will hold a minimum File capacity, linear file inches (L.F.I.) of 1,261 LFI, optimized to
fit the space allocated.
7. Computer Interface – To controller located in work counter.
8. Unit will offer a manual bi-parting door with lock.
9. The model shall have self- balancing design such that units will not jam, tilt or skew, or
otherwise become inoperable due to heavy shelves, empty shelves or uneven loading.
10. The unit shall have an automatic on/off interior task lighting integrated into the unit.
11. The unit shall be self-contained and not require any building modifications to install (i.e.
subfloor). Vendor shall be responsible to ensure fit, form, and function of the file system
including operator access within this room while maximizing capacity in LFI. The unit shall
allow entry and exit access, and adequate access to the transaction counter of the unit.
12. Materials – This high-density vertical system shall be of high-quality steel construction with
an automotive grade painted finish.
13. Electrical – Unit to plug into existing 110-volt wall outlet or hard wired into the outlet.
CLIN 0001 Statement of Work specific information:
1. The contractor shall coordinate delivery, assembly, and installation of the BRAND
NAME or EQUAL MEG 125-1311S VCM unit.
2. The contractor shall dispose all waste, garbage, or debris in accordance with all federal,
state, and local guidelines and regulations.
3. The contractor shall test operability and provide training on the system prior to
acceptance.
FA462026QA218
Attachment 1 - Statement of Work
3 of 3
-- 3 of 3 --
Source: SAM.gov, as posted. Verify the current solicitation before responding.