Hazardous Waste Storage

DEPT OF DEFENSE

Notice type
Combined Synopsis/Solicitation
Solicitation #
N6660426Q0316
NAICS
332311
PSC
5410
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
July 16, 2026
Response due
July 28, 2026
Place of performance
Newport, RI

What this opportunity is

The DEPT OF DEFENSE is procuring a Hazardous Waste External Storage Module for the Naval Undersea Warfare Center Division Newport, a Total Small Business Set-Aside opportunity under NAICS code 332311. The notice type is a Combined Synopsis/Solicitation, requiring offerors to track the solicitation for updates. This procurement is suitable for small businesses that can provide a modernized, fully compliant hazardous waste storage module meeting or exceeding the technical specifications outlined in the tables.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

v4.0_JULY2024 1 STATEMENT OF WORK (SOW) Procurement of Hazardous Waste External Storage Module 1.0 Background Naval Undersea Warfare Center Division Newport requires a new hazardous waste storage module. 1.1 Places of Performance Work to be performed will be to provide NUWC with a new hazardous waste module as listed by requirements and identified specifications. 1.2 Authorized Users Authorized for Code 1023 1.3 Sponsors Sponsored by Code 1023 1.4 Types of Funding Overhead funding to be used for procurement 2.0 Scope This Statement of Work (SOW) defines the technical and operational requirements for the procurement, delivery, and turnkey installation of one (1) Hazardous Waste External Storage Module for the Naval Undersea Warfare Center Division Newport (NUWCDIVNPT), Code 1023. The objective of this acquisition is to safely replace the legacy storage unit with a modernized, fully compliant module that ensures the secure segregation and environmental containment of hazardous materials in support of the NUWCDIVNPT mission 2.1 Program or Systems Supported Contract is to support Code 1023 Hazardous Waste Program 3.0 Applicable Documents The contractor shall perform the tasking required in Section 4.0 in accordance with (IAW) the below Applicable Documents (ADs). NUMBER TITLE REVISION/ DATE APPLICABLE SOW TASK 3.1 Industry Standards 3.1.1 NFPA 70 National Electric Code ALL 3.1.2 ASTM E119 ALL -- 1 of 6 -- v4.0_JULY2024 2 3.1.3 NFPA 30 ALL 3.1.4 NFPA 704 ALL 3.1.5 NFPA 400 ALL 3.1.6 International Building Code ALL 3.1.7 OSHA 1910 ALL 4.0 Technical Requirements In accordance with Federal procurement mandates, the Government strongly encourages the proposition of Commercial-Off-The-Shelf (COTS) or modified commercial items. While legacy system dimensions and configurations are referenced herein to establish baseline physical footprint and capacity constraints, they are not intended to be overly restrictive. Offerors are encouraged to propose commercial solutions that meet or exceed the functional, safety, and capacity requirements outlined in this SOW, even if the exact dimensional configuration differs from the legacy module. The Contractor shall provide a chemical storage building meeting or exceeding the technical specifications outlined in the tables below: 4.1.1 Chemical Storage Building Design Requirement Ref Feature / Parameter Performance Specification 4.1.1.1 Compartmentalization Building shall be divided into three (3) separate equal compartments separated by an internal barrier wall extending from the sump base to the ceiling. 4.1.1.2 External Dimensions Nominal dimensions: approximately 9’ H x 34’ W x 9’ D (Tolerance of ±3 feet permitted for any dimension to accommodate COTS designs). 4.1.1.3 Safety Certification The module must be certified by an OSHA-recognized Nationally Recognized Testing Laboratory (NRTL), such as being UL Listed or FM Approved, for hazardous material storage. 4.1.1.4 Fire Rating Exterior and interior barrier walls must possess a minimum 4- hour fire rating. 4.1.1.5 Access Doors Three (3) double doors, minimum 84" W x 80" H; minimum 3- hour fire rating; equipped with self-closing mechanisms. -- 2 of 6 -- v4.0_JULY2024 3 4.1.1.6 Insulation Fully insulated structure with a minimum R11 insulation rating through the walls and ceiling. 4.1.1.7 Coating & Finish Chemical-resistant interior and exterior coatings; exterior coating must be UV-rated. 4.1.1.8 Placards & Labeling Three (3) fixed DOT metal flip placards per module bay; three (3) pressure-sensitive NFPA 704 Hazard Rating signs per bay door. 4.1.1.9 Shelving No interior shelving is to be installed. 4.1.1.10 Flooring & Sump Galvanized steel floor grating with removable galvanized steel supports. Minimum built-in sump capacity of 1,000 gallons; minimum floor load rating of 250 psf. 4.1.1.11 Lifting and Rigging The module shall be designed and engineered for safe relocation at empty weight utilizing both forklift and/or crane lifting equipment. The base structure shall feature fully welded, integrated forklift pockets spanning the full width of the module and sized to accommodate standard heavy-duty industrial forklift tines. For overhead rigging, the module shall be equipped with a minimum of four (4) top-mounted, structurally reinforced crane lifting lugs (or hoist rings) welded directly to the upper roof frame corners to allow secure shackle attachment. 4.1.2 Electrical and Climate Control Systems Requirement Ref System Component Technical Specification 4.1.2.1 Electrical Distribution Load Center compatible with 120/208V configurations; protected in weatherproof NEMA enclosures. Load Center desired to be designed/installed on left-side if technically capable. 4.1.2.2 Interior Lighting Three (3) Explosion-Proof LED light fixtures with integrated light switch(es) (Class 1, Division 2 rating). 4.1.2.3 Heating Three (3) Explosion-Proof fan-forced heaters controlled by dedicated thermostats (Class 1, Division 1 & 2 rating). 4.1.2.4 Cooling Three (3) Explosion-Proof air conditioning units with color-coded thermostats (Class 1, Division 2 rating). 4.1.2.5 Ventilation Three (3) Explosion-Proof exhaust systems equipped with visual status indicators and emergency shut-off switches. -- 3 of 6 -- v4.0_JULY2024 4 4.1.2.6 Dampers Three (3) gravity-fed air inlet vents equipped with 3-hour fire-rated fusible link dampers. 4.1.2.7 Grounding Comprehensive internal and external grounding terminal systems. 4.1.3 Safety, Accessories, and Delivery Requirement Ref Category Performance Specification 4.1.3.1 Fire Suppression Pre-engineered ABC Dry Chemical fire suppression system complete with local audible alarms. 4.1.4.1 Accessories One (1) relocatable heavy-duty steel access ramp compatible with skid- resistant finishes, designed to be movable and compatible across all double-door entryways. 4.1.5.1 Delivery Site F.O.B. Destination delivery at NUWCDIVNPT, Newport, RI. 5.0 Progress Reports 5.1 Contract Status Report Reserved 5

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Similar Active Opportunities (NAICS 332311)