J012--Fire Sprinkler Repairs

VETERANS AFFAIRS, DEPARTMENT OF

Notice type
Sources Sought
Solicitation #
36C26226Q0654
NAICS
238220
PSC
J012
Set-aside
Service-Disabled Veteran-Owned Small Business Set Aside
Posted
June 5, 2026
Response due
June 19, 2026
Place of performance
Tucson

What this opportunity is

The Department of Veterans Affairs is seeking fire sprinkler repair services under NAICS 238220, specifically for the VA San Diego Healthcare System. This opportunity is set aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB). Interested contractors should note that this is a Sources Sought notice, indicating the government is gathering information rather than soliciting bids at this time; tracking this opportunity may lead to future bidding opportunities.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

SUBJECT* Fire Sprinkler Repairs GENERAL INFORMATION CONTRACTING OFFICE’S ZIP CODE* 85723 SOLICITATION NUMBER* 36C26226Q0654 RESPONSE DATE/TIME/ZONE 06-19-2026 1:00 PM MOUNTAIN TIME, DENVER, USA ARCHIVE 30 DAYS AFTER THE RESPONSE DATE RECOVERY ACT FUNDS N SET-ASIDE SDVOSBC PRODUCT SERVICE CODE* J012 NAICS CODE* 238220 CONTRACTING OFFICE ADDRESS Department of Veterans Affairs NCO 22 - Network Contracting 11201 Benton St. Loma Linda CA 92357 POINT OF CONTACT* Contract Specialist Diana McInnis diana.mcinnis@va.gov 951-601-4352 PLACE OF PERFORMANCE ADDRESS Department of Veterans Affairs NCO 22 - Network Contracting 3601 S. 6th Avenue Tucson AZ POSTAL CODE 85723 COUNTRY ADDITIONAL INFORMATION AGENCY’S URL URL DESCRIPTION AGENCY CONTACT’S EMAIL ADDRESS EMAIL DESCRIPTION DESCRIPTION STATEMENT OF WORK CONTRACT TITLE: Fire Sprinkler repairs PLACE OF PERFORMANCES: VA San Diego Healthcare System 3350 La Jolla Village Dr. San Diego, CA 92161 PERIOD OF PERFORMANCE: 07/01/2026-06/30/2027 CONTRACT TYPE: Firm Fixed Price BACKGROUND: Fire sprinkler deficiencies from 2025 annual inspection and testing. GENERAL REQUIREMENTS: Per applicable VA San Diego requirements/standards, the contractor will: BLDG 1 WETPIPE REQUIRED REPAIRS: **** 6TH FLOOR **** NORTH: The following areas were found to have 50yr old sprinklers: 6231 (2), 6232 (2), 6233A (2), 6242 (2), 6239 (2), 6240, 6233 (2), 6243 (2), 6254 (6), 6245 (2), 6246 (4), 6246A (2), 6230 (4), 6252B (2), 6252C (1), 6252E (4), 6247 (2), 6249 (2), 6250 (1), 6251 (1), 6254 (6), 6254A (2), 6256 (2), 6257 (2), 6264 (1), 6254B (2), 6263 (2), 6267 (6), 6268 (1), 6269 (2), 6259 (2),6263A (1), 6224 (1), 6225 (1), 6219 (2), 6218 (2), 6217 (4), 6215 (1), 6268 (2). Replace (88) 165° STD ½” Chrome SSP 401chrome trim. WEST: The following areas were found to have 50yr old sprinklers: 6097 (1), 6024 (1), 6035 (4), 6025 (2), 6032 (2), 6030(4), 6070 (1), 6029 (2), 6083 (2), 6082 (2), 6050 (1), 6045 (2), 6080 (1), 6081 (14), 6062 (3), 6048 (2), 6051 (2), 6049 (2), 6052(5), 6055 (3), 6058 (2), 6061 (2), 6056A (2), 6069 (2), 6074 (2), 6086 (2), 6087 (2), 6088 (4), 6095 (2), 6096 (2), 6091 (1), 6091A(1). Replace (82) 165° STD ½” chrome SSP 401 chrome trim. SOUTH: The following areas were found to have 50yr old sprinklers: 6105 (3), 6107 (4), 6110 (4) 6118 (2), 6112 (1). Replace(14) 165° STD ½” chrome SSP 401 chrome trim. EAST: The following areas were found to have 50yr old sprinklers: 6149 (1), 6150 (4), 6153 (2), 6160 (1), 6163 (2), 6164 (4),6169 (2), 6170 (2), 6171 (2), 6172 (2), 6176 (2), 6174C (3), 6174G (4), 6174F (4), 6184 (2), 6189A (3), 6189C (2), 6187 (1), 6190(1), 6191 (2), 6192 (2), 6197 (1), 6198 (2) , 6200 (3), 6202 (2), 6203 (2), 6204 (2), 6205 (2), 6207 (2). Replace (66) 165° STD ½”chrome SSP 401 chrome trim. CORE: Housekeeping closet 6010 replace (1) corroded 155° QR ½” chrome SSP SRC trim. NORTH: 6254B replace (2) 20yr old 155° QR ½” chrome SSP 399 chrome trim (2001). NORTH: 6252A next to cage washer door replace (1) corroded 200° QR ½” chrome SSP 401 Chrome trim. NORTH: 6268 replace (2) 20yr old 155° QR ½” chrome SSP 401 chrome trim (2001). WEST: refrigerator 6037 replace (2) 20yr old 200° QR 1” x 12” chrome dry pendant w/ chrome trim (2002). NOTE: This will require majority stitch work. WEST: 6028 replace (2) loaded/corroded 155° QR ½” chrome SSP 401 chrome trim. WEST: 6044A in 6043 replace (1) corroded 155° QR ½” white SSP SRW. WEST: 6044 entry replace (1) corroded 155° QR ½” white SSP SRW. WEST: 6040 women’s bathroom shower replace (1) corroded 155° STD ½” chrome SSP 401 chrome. WEST: refrigerator 6081E replace (1) 10yr old 200° STD 1” x 12” chrome dry pendant w/ chrome trim (2013). NOTE: this will require majority stitch work. WEST: 6070 refrigerator replace (1) 10yr old 200° STD 1” x 12” chrome dry pendant w/ chrome trim (2013). NOTE: this will require majority stitch work. WEST: 6056A & 6057 replace (2) 20yr old 155° QR ½” chrome SSP SRC trim (2001). WEST: 6062 replace (3) 20yr old 155° QR ½” chrome SSP 401 chrome trim (2002). WEST: 6070 replace (1) 20yr old 155° QR ½” white SSP SRW trim (2004). WEST: 6091 & 6091A replace (2) 20yr old 155° QR ½” chrome SSP 401 chrome trim (2002). SOUTH: 6104 refrigerator replace (1) 10yr old 200° STD 1” x 12” chrome dry pendant w/ chrome trim (2013). NOTE: this will require majority stitch work. SOUTH: 6108A replace (4) corroded 165° STD ½” chrome SSP 401 chrome trim. SOUTH: 6112 replace (1) 20yr old 155° QR ½” chrome SSP 401 chrome trim (2005). SOUTH: 6112 refrigerator replace (1) 10yr old 200° STD 1” x 12” chrome dry pendant w/ chrome trim (2013) this will require majority stitch work. NOTE: Inside refrigerator is very warm! EAST: hallway leading to stair 12 replace (9) corroded 155° STD ½” white SSP 401 white trim. EAST: 6155 replace (2) corroded 165° STD ½” chrome SSP 401 chrome trim. EAST: refrigerator 6166 replace (2) 10yr old 200° QR 1” x 12” chrome dry pendant w/ chrome trim (2013). NOTE: this will require majority stitch work. EAST: 6179 replace (2) corroded 165° STD ½” chrome SSP 401 chrome trim EAST: 6197A in 6198 replace (3) corroded 165° STD ½” chrome SSP 401 chrome trim **** 5TH FLOOR **** SOUTH: exterior core hallway from stair 11 to dead end into east wing replace (7) corroded 155° QR ½” White SSP 401 white trim. NORTH: exterior core hallway to stair 9 replace (5) corroded 155° QR ½” white SSP 401 white. These Sprinklers are also near 20yrs old (2008). NORTH: hallway outside 5315 replace (1) corroded 155° QR ½” chrome SSP SRC trim. WEST: 5004 next to 5003 men’s bathroom replace (2) corroded 155° QR ½” chrome SSP 401 chrome Trim. CORE: hallway to south wing door replace (4) 20yr old 155° QR ½” chrome SSP SRC trim. CORE: 5019 replace (1) 20yr old 155° QR ½” chrome SSP SRC trim. CORE: 5020 repl

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Similar Active Opportunities (NAICS 238220)