MRR Korea

DEPT OF DEFENSE

Notice type
Presolicitation
Solicitation #
PANHES-25-P-0000-003248-MRR-Korea
NAICS
236220
PSC
Z2DA
Set-aside
No Set aside used
Posted
July 24, 2026
Response due
August 3, 2026

What this opportunity is

The Department of Defense is soliciting a contractor for the Medical Facilities Repair and Renewal (MRR) Project, a construction project that involves various tasks such as site investigation, hazard assessment, and construction work. This project is not set aside for a specific business type, and the notice type indicates that the government is currently gathering information and may issue a solicitation in the future. The project requires a contractor to have experience in construction management, as indicated by the NAICS code 236220.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

PROJECT TABLE OF CONTENTS DIVISION 01 - GENERAL REQUIREMENTS 01 11 00 SUMMARY OF WORK 01 30 00 ADMINISTRATIVE REQUIREMENTS 01 32 01.00 10 PROJECT SCHEDULE 01 33 00 SUBMITTAL PROCEDURES 01 33 16.00 10 DESIGN DATA (DESIGN AFTER AWARD) 01 33 29 SUSTAINABILITY REQUIREMENTS AND REPORTING 01 35 26 GOVERNMENTAL SAFETY REQUIREMENTS 01 45 00.00 10 QUALITY CONTROL 01 45 00.15 10 RESIDENT MANAGEMENT SYSTEM CONTRACTOR MODE (RMS CM) 01 50 00 TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS 01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS 01 58 00 PROJECT IDENTIFICATION 01 73 19 REMOVAL, RELOCATION, OR INSTALLATION OF GOVERNMENT-FURNISHED PROPERTY 01 74 19 CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL 01 78 00 CLOSEOUT SUBMITTALS 01 78 23 OPERATION AND MAINTENANCE DATA 01 91 00.15 10 TOTAL BUILDING COMMISSIONING -- End of Project Table of Contents -- PROJECT TABLE OF CONTENTS Page 1 SECTION TABLE OF CONTENTS DIVISION 01 - GENERAL REQUIREMENTS SECTION 01 11 00 SUMMARY OF WORK PART 1 GENERAL REFERENCES DEFINITIONS Sustainable Development Site Investigation Work Plan (Design Submittal) Medical Facilities Repair and Renewal (MRR) Project Medical Facilities Repair and Renewal (MRR) Action Task Order SUBMITTALS WORK COVERED BY CONTRACT DOCUMENTS Project Description Location CERTIFICATION OF TASK ORDERS OCCUPANCY OF PREMISES EXISTING WORK LOCATION OF UNDERGROUND UTILITIES Notification Prior to Excavation SECURITY REQUIREMENTS PART 2 PRODUCTS PART 3 EXECUTION LEVEL OF EFFORT ACTIVITIES UNDER MEDICAL REPAIR AND RENEWAL (MRR) PROJECTS Site Investigation Site Investigation Site Investigation Report Site Description Site Information Hazard Assessment and Risk Analysis Problem Areas Disruption Plan Asbestos and/or Lead Containing Material Abatement (Removal/Encapsulation) Identification Hazmat Survey Preliminary Studies Work Plan (Design Submittal) MRR Construction -- End of Section Table of Contents -- SECTION 01 11 00 SUMMARY OF WORK PART 1 GENERAL REFERENCES Obtain and update all publications listed below as well as any others that are used in response to the requirements of task orders. Work done under the individual task orders shall utilize the latest issue of the publications dated at the time of award of the task order. When a required publication is not referenced in this list, or in the task order, the Contractor shall utilize a commercial standard that has national applications. The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only. INTERNATIONAL CODE COUNCIL (ICC) ICC IPC International Plumbing Code NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) NFPA 101 Life Safety Code U.S. ARMY CORPS OF ENGINEERS (USACE) EP 310-1-6a Sign Standards Manual, VOL 1 EP 310-1-6b Sign Standards Manual, VOL 2, Appendices ERDC/ITL TR-12-6 A/E/C CAD Standard - Release 6.0 U.S. ARMY CORPS OF ENGINEERS, HUNTSVILLE CENTER (CEHNC) HNC-PR-ED-2000.10 HNC Engineering Guidance Design Manual U.S. DEPARTMENT OF DEFENSE (DOD) MIL-STD-1691 Construction and Material Schedule for Military Medical and Dental Facilities U.S. DEPARTMENT OF DEFENSE (DOD) UFC 1-200-01 DoD Building Code UFC 1-200-02 High Performance and Sustainable Building Requirements UFC 1-300-08 Criteria for Transfer and Acceptance of DoD Real Property UFC 3-101-01 Architecture UFC 3-110-03 Roofing UFC 3-120-10 Interior Design UFC 3-201-01 Civil Engineering UFC 3-250-01 Pavement Design for Roads and Parking Areas UFC 3-220-01 Geotechnical Engineering UFC 3-240-01 Wastewater Collection and Treatment UFC 3-301-01 Structural Engineering UFC 3-410-01 Heating, Ventilating, and Air Conditioning Systems UFC 3-410-02 Direct Digital Control for HVAC and Other Building Control Systems UFC 3-420-01 Plumbing Systems UFC 3-490-06 Elevators UFC 3-501-01 Electrical Engineering UFC 3-520-01 Interior Electrical Systems UFC 3-530-01 Interior and Exterior Lighting Systems UFC 3-575-01 Lightning & Static Electricity Protection Systems UFC 3-580-01 Telecommunications Interior Infrastructure Planning & Design, with Change 1 UFC 3-600-01 Fire Protection Engineering for Facilities UFC 4-010-01 DoD Minimum Antiterrorism Standards for Buildings UFC 4-021-01 Design and O&M: Mass Notification Systems UFC 4-510-01 Design Military Medical Facilities DEFINITIONS Sustainable Development Definitions pertaining to sustainable development are as defined in UFC 1-200-02, Section 01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS, and as specified. "Environmentally preferable products" have a lesser or reduced effect on the environment in comparison to conventional products and services. This comparison may consider raw materials acquisition, production, manufacturing, packaging, distribution, reuse, operation, maintenance, or disposal of the product. "Indoor environmental quality" is the physical characteristics of the building interior that impact occupants, including air quality, illumination, acoustics, occupant control, thermal comfort, daylighting, and views. "Operational performance" is the functional behavior of the building as a whole or of the building components. "Sustainability" is the balance of environmental, economic, and societal considerations. Site Investigation The site investigation is an inspection of an installation, facility, or system to evaluate areas and to obtain specific information pertaining to a MRR action. Validation of the task order scope of work (SOW) shall also be accomplished during the initial site meeting. During the process of verification of the SOW each item must be reviewe

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Similar Active Opportunities (NAICS 236220)