What this opportunity is
The Department of the Interior is soliciting bids for the replacement of three HVAC systems at various locations in Newbury Park, California, under NAICS code 238220. This opportunity is set aside for Service-Disabled Veteran-Owned Small Businesses, making it suitable for qualified small contractors in the HVAC sector. Interested vendors should note that this is a solicitation notice, indicating that they can submit proposals rather than simply track the opportunity.
Analysis by Mindy, grounded in the SAM.gov notice.
Description
Statement of Work
HVAC System Replacement- Rancho Sierra Vista (RSV) Satwiwa Cultural
Center, RSV Dormitory, and Diamond X (DX) Ranch House
June 2026
This contract will be for three separate building HVAC replacements as listed below.
The specifications outlined below provide a comprehensive description of the required
work.
1. RSV Satwiwa Cultural Center at 4132 West Potrero Rd, Newbury Park, CA
91320.
Remove and replace existing 4-ton split system with new 4-ton split system which
includes:
1. Remove the old furnace, evaporator, and a/c unit.
2. Line the furnace floor with sheet metal.
3. Line the return box with duct board to satisfy Title 24 2005 Conditional Air
Requirements.
4. Install a new Energy Star digital, programmable thermostat. Similar or like Model
Honeywell T6 Wi-Fi
5. Install a new 80% efficient furnace. Similar or like Series #GMC80
6. Custom fabricated supply plenum all seams to be sealed and insulated with R-6.
7. Install a new gas shut off and connector and configure for propane operation.
8. Install a new transitional vent.
9. Recover and reclaim the old Freon per EPA standards.
10. Install a new evaporator.
11. Install a safety drain float kit at the secondary drain outlet to help prevent potential
water damage.
12. Install a new 14 SEER, condensing unit. Similar or like Series #GMC14
13. The A/C unit properly quake-strapped with a new a/c pad.
14. Perform a high-pressure nitrogen leak test and purge on the refrigeration system.
15. Install a new fused service disconnect at the condenser unit location and fuse down to
the proper amp using HVACR fuses only.
16. Encase exterior low-voltage control wire.
17. Install a high-quality filter assembly.
2. RSV Dormitory at 4130 Potrero Rd, Newbury Park, CA, 91320:
Furnace System:
1. Remove the old furnace, evaporator, and a/c unit.
2. Line the furnace floor with sheet metal.
3. Line the return box with duct board to satisfy Title 24 2005 Conditional Air Requirements.
-- 1 of 5 --
RFQ 140P8626Q0040 Replace Three (3) HVAC Systems
Attachment 1 Statement of Work Santa Monica Mountains National Recreation Area
2
4. Install a new Energy Star digital, programmable thermostat. Wi-Fi thermostat.
5. Install a new 80% efficient, 3T single stage furnace. Similar or like Series #GM9S80.
6. Custom fabricated supply plenum all seams to be sealed and insulated with R-6.
7. Install a new gas shut-off and connector.
8. Any air imbalances currently existing in the duct system may still be present after a new
furnace is installed.
9. Install a new transitional vent.
10. Recover and reclaim the old Freon per EPA standards.
11. Install a new evaporator.
12. Install a safety drain float kit at the secondary drain outlet to help prevent potential
water damage.
13. Install a new 3T, up to 18 Seer, Variable speed condensing unit. Similar to or like model
Series #Innovair slim 24
14. The A/C unit properly quake-strapped with a new a/c pad.
15. Perform a high-pressure nitrogen leak test and purge on the refrigeration system.
16. Install a new fused service disconnect at the condenser unit location and fuse down to
the proper amp using HVACR fuses only.
Duct Work:
1. Remove accessible old ducting located in attic.
2. Design and install a new high quality MHP, R-6.0 ducting system per California Title 24
Codes.
3. All exposed metals will be insulated and ducts will be properly supported and/or hung.
4. All stack heads will be screwed and sealed to their drop boxes to prevent air leaks.
5. All existing wall and ceiling drop boxes will be sealed at all seams.
6. The system will be leak checked and air balanced per California Manual D codes.
Insulation:
Removal and Blow-in - R38 JM Climate Pro® blow-in fiberglass insulation or similar or like
insulation.
3. DX Ranch House at 26412 Mulholland Highway, Calabasas, CA 91302:
1. Removal & Disposal
The contractor shall remove and dispose of all existing HVAC equipment in an
environmentally safe manner. This includes:
• Two existing gas furnaces
• Two evaporator coils
• Two existing outdoor units
• Associated ductwork sections scheduled for replacement
• Old thermostats and low-voltage wiring no longer required
• Recovery and reclamation of refrigerant per EPA requirements
2. Heating System Installation (Two Furnaces)
Provide and install two high-efficiency forced-air gas furnaces, meeting the following
requirements:
-- 2 of 5 --
RFQ 140P8626Q0040 Replace Three (3) HVAC Systems
Attachment 1 Statement of Work Santa Monica Mountains National Recreation Area
3
• Heating output approximately 100,000 BTU each (or as required by load calculation)
• Single-stage gas valve operation
• Fully compatible with indoor evaporator coils and outdoor heat-pump/condenser
system
• Insulated blower compartments for noise reduction
• New venting installed or modified to meet current code
• New gas shutoff valves and flexible connectors installed at each furnace
• Contractor shall confirm furnace sizing based on Manual J or equivalent load
calculation methodology.
3. Indoor Coil Installation (Two Matched Coils)
Provide and install two vertical-configuration evaporator coils, meeting these
specifications:
• Sized to match the outdoor heat-pump/condenser capacity
• Aluminum or copper high-efficiency fin-type coil
• Fully compatible with system refrigerant
• All coil penetrations sealed with water-soluble, non-toxic sealant
• Proper secondary drain outlet with float safety switch
4. Outdoor Heat Pump / Condenser Installation (Two Units)
Provide and install two high-efficiency air-source heat pump / condenser units, each
meeting minimum performance standards:
• Cooling capacity: approx. 12,000 BTU (or capacity required by load calculation)
• Heating capacity: approx. 12,000 BTU
• Minimum 16 SEER efficiency rating
• Inverter-driven variable-speed compressor
• Outdoor operating sound rating not to exceed 52 dB(A)
• Mounted on UV-resistant pad or stand
• Sound and vibration isolators installed
• All penetrations sealed to prevent intrusi…
Source: SAM.gov, as posted. Verify the current solicitation before responding.
Pursue this opportunity with Mindy
See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.
View the original notice on SAM.gov ↗Similar Active Opportunities (NAICS 238220)
N--George Washington Birthplace National Monument- RE
INTERIOR, DEPARTMENT OF THE · Solicitation · due June 26, 2026
RFQ - RFQ - 19ZA6026Q0004 - FAC NEC CHILLER MAINTENANCE- FAC NEC CHILLER MAINTENANCE
STATE, DEPARTMENT OF · Solicitation · due July 20, 2026
Installation of an Engineered Fire Suppression System
DEPT OF DEFENSE · Solicitation · due June 25, 2026
J045--High Pressure Steam Piping Replacement
VETERANS AFFAIRS, DEPARTMENT OF · Combined Synopsis/Solicitation · due July 6, 2026
1698- CE Chiller Maintenance/Service Recompete
DEPT OF DEFENSE · Solicitation · due June 22, 2026
VGLZ 252018 - Repair HVAC Building 303
DEPT OF DEFENSE · Presolicitation