NASA is procuring a fully interchangeable replacement Liquid Nitrogen Pump 12, essential for the National Transonic Facility's operations. This opportunity is set aside for total small businesses, suitable for firms specializing in mechanical and electrical engineering, particularly those with experience in cryogenic systems. Interested vendors should note that this is a combined synopsis/solicitation, indicating they should track the notice for further details rather than submit bids immediately.
Analysis by Mindy, grounded in the SAM.gov notice.
Description
1 Title: Procure Fully Interchangeable Replacement Liquid Nitrogen Pump 12
2 Background:
The National Transonic Facility is a high-pressure, cryogenic, closed-circuit wind tunnel
that uses supercold nitrogen gas at high pressure to duplicate true flight aerodynamics.
The Liquid Nitrogen Pump 12 (P12) is one of the pumps that supplies liquid nitrogen to the
facility. Liquid Nitrogen is stored in the 3000 Ton tank and then transferred to the 800 Ton
tank. This task is to procure a fully interchangeable critical spare for P12.
3 Description of work to be performed:
This task is to procure a Liquid Nitrogen Pump with the same mechanical, electrical, and
controls interfaces as the existing Cryostar CS400/355/20L Pump with Serial Number
96013/02.
3.1 Existing Pump Specifications:
- Single Stage
- 400 mm nominal impeller diameter
- 355 mm trimmed impeller diameter
- 20 mm tip width
- 1780 rpm
3.2 Operating Data
- LN2
- (-195°C) Liquid Temperature
- 5 barg Maximum Suction Pressure
- Minimum NPSH 1.4m
- 1300 gpm Flow Rate
- Differential Head 180 ft.
3.3 Existing Motor Specifications
- 405 TD, NEMA
- 60 Hz, 3 Phase, 480V, 100 Hp
- Unclog and verify orifice plug.
- Clean cable block in prep for unit assembly.
-- 1 of 3 --
3.4 Performance Curves
-- 2 of 3 --
3.5 New Pump Specifications
- LIN Transfer – MCP 400/20L-1.7-CB-WB C/0
Vertical centrifugal pump
PT100 Sensor in lantern for seal leakage detection
Heating cable for thermal barrier
Grease retaining chamber with N2 purge
Close warm box with N2 purge
2-chamber labyrinth seal
Cold box isolation plate
- Electric motor LSES280SD of 75kW – 4 poles – fixed speed – 480V – 60 Hz
Anticondensation heater 120V in separate Junction Box
3xPTC in winding
2XPT100 at Drive End bearing
Grease nipples
Painting type C3 according to ISO 12944-2
- Seal gas control panel (installed and fully wired onto the pump)
- Labyrinth seal Low Pressure Drop control panel according to preliminary panel drawing
No 763206054 and to preliminary P&ID No 704206221-41
- Including mechanical performance test in cryogenic conditions with LIN on duty point
- Documentation as per Cryostar standard limited to IOM, Assembly checklist and
Performance test report in PDF sent by email
3.6 Spare parts
- Commissioning Kit for Installation and Start-up
3.7 Seaworth Packing
4 Period of Performance
This valve shall be procured and delivered to Langley prior to June 30, 2027.
5 Shipping Address
NASA Langley Research Center
Central Receiving
4 South Marvin Street
Building 1206
Hampton, VA 23681-2199
-- 3 of 3 --
Source: SAM.gov, as posted. Verify the current solicitation before responding.