What this opportunity is
The Department of Defense is seeking a contractor to perform plumbing repairs, specifically the removal and replacement of toilets waste lines at Building TNG-1, Fort Gordon, GA. This opportunity is set aside for total small businesses under NAICS 238220, which covers plumbing, heating, and air-conditioning contractors. Interested bidders should note that this is a solicitation notice, meaning they will need to prepare and submit bids by the deadline of 10 June 2026, and a site visit is encouraged to understand the project scope.
Analysis by Mindy, grounded in the SAM.gov notice.
Description
Statement of Work (SOW)
Project Title: Toilets Waste Line Removal and Replacement
Location: Building TNG-1, Fort Gordon, GA
1.0 Scope of Work
The Contractor shall remove all existing drain lines serving the Toilets in the male and
female latrines of Building TNG-1. Dispose all debris and install new 4-inch piping with
proper slope / pitch per plumbing code from the Toilets groups to the clean-out sweep
located just outside the building. The Contractor shall reconnect all disturb sink and
urinal lines. All Toilets, urinals, and sinks must be fully operational upon completion. The
Contractor shall furnish all labor, materials, equipment, and supervision necessary to
complete the work in accordance with applicable codes and standards.
2.0 Project Requirements
2.1 Demolition and Removal
Removal of all existing Toilets waste piping serving both male and female
latrines.
Disconnect piping only as required to avoid damage to finished surfaces.
All removed materials shall be disposed of in accordance with federal, state, and
local regulations.
2.2 Installation of New Piping
The Contractor shall install new 4-inch sanitary piping in accordance with plumbing
code, including slope / pitch, support, and alignment requirements.
2.2.1 Fixture Reconnection
The following fixtures shall be reconnected only if temporarily disconnected:
Fixture Type Quantity Location
Toilets 8 total (4 female, 4 male) Latrines
Sinks 5 total (2 female, 3 male) Latrines
Urinals 3 Mens latrine
Floor Drains 2 total (1 per side) Latrines
Janitor/Mud Room Clean-outs 2 total Utility rooms
-- 1 of 2 --
All reconnections shall be watertight and code-compliant.
All Toilets must flush properly and drain without obstruction.
2.2.2 Toilets Waste Line Installation
Install new 4-inch piping from each Toilets group to the exterior clean-out sweep.
Ensure proper slope / pitch per plumbing code.
Provide all required hangers, supports, and fittings. Support all piping using all-
thread rod and steel pipe clamps
Ensure all piping is installed to maintain proper flow and prevent blockages.
2.3 Testing and Verification
Test all toilets, urinals and sinks for proper flushing and drainage.
Verify no leaks, blockages, or improper slope conditions.
Provide final inspection to the Government for acceptance.
3.0 General Requirements
Contractor shall comply with all OSHA, federal, state, and local safety
regulations.
Contractor shall coordinate all inspections with the Government.
Contractor shall maintain a clean and safe worksite at all times.
Work shall be performed during approved working hours unless otherwise
authorized.
Contractor shall protect all existing finishes, utilities, and building components
from damage.
4.0 Deliverables
Demolition and installation completion report
As-built sketch showing new piping layout
Inspection and testing documentation
5.0 Final Acceptance
The Government will perform a final inspection. The project will be accepted once all
Toilets flush properly, all reconnections are verified, and all work meets code and
contract requirements.
-- 2 of 2 --