PURCHASE HAZMAT STORAGE BLDGS FOR WRANGEL ST ELIAS

INTERIOR, DEPARTMENT OF THE

Notice type
Solicitation
Solicitation #
140P9726Q0061
NAICS
332311
PSC
5410
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
July 16, 2026
Response due
August 3, 2026

What this opportunity is

The Department of the Interior is seeking to procure up to two hazardous material storage buildings for its Copper Center, Alaska facility, under a Total Small Business Set-Aside. These buildings must meet specific federal safety, environmental, and fire-protection standards, including features like a spill containment sump and a compliant locking system. Interested small businesses should note that this is a solicitation notice, indicating that they can submit bids for the project.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

Hazardous Material Storage Building Procurement Document (Revised) Background This procurement document outlines the requirements for the acquisition of a hazardous material storage buildings for use at the Copper Center, Alaska facility. The building will support compliant storage of hazardous materials and fuels. Requirements The Government requires up to two (2) hazardous material storage building meeting federal safety, environmental, and fire-protection standards. Contract Line Item Numbers (CLINs) 1. CLIN 0001 – Hazardous Material Storage Buildings, A steel, double-wall hazardous material storage enclosure meeting minimum size requirements of 8 ft 3 in height, 26 ft width, and 8 ft depth, with spill containment sump, ventilation, and compliant locking system. Provide one 60” wide x 80” high double door to facilitate the unloading and loading of hazardous material within the building. Installed with a UL Classified commercial grade keyed lockset. The double door shall have one active leaf to serve as personnel entrance and exit. The active leaf must be equipped with a door closer. Provide built-in 7-inch high spill containment sump with chemical resistant coating. Sump construction to be weather proof, noncombustible utilizing continuously welded steel sheets for maximum spill containment protection. Mechanical fastener penetrations cannot be used on sump wall skins. Sump capacity to be a minimum 25% of total storage capacity of the building. Floor planking above sump area shall be galvanized steel for maximum corrosion resistance. Floor planking must be designed to sustain a minimum uniformly distributed load of 250 pounds per square foot (psf). Floor planking supports must be removable to facilitate sump cleaning in the event of a spill. Permanent or welded in place floor supports are unacceptable. -- 1 of 4 -- Building Base Provide open channel design to allow visual inspection under building. Crane/forklift opening to be provided for ease in off-loading and relocation. Interior Finish Finish on ceiling, walls, and sump floor with a two-part chemical resistant gray aliphatic polyurethane. Able to withstand salt spray/chemical rub and durable to impact damage. Exterior Finish Finish on roof, walls, and doors surfaces with a two-part chemical resistant gray aliphatic polyurethane. UV protection. Able to withstand salt spray/chemical rub and durable to impact damage. Signs/Labeling Provide one permanent all metal DOT hazard classification placard with rustproof aluminum holder and one pressure sensitive NFPA 704 hazard rating sign on door. Air Inlet Vents Provide air inlet vents for natural ventilation. Natural ventilation shall provide a rate of 1cubic foot per min per square foot of floor space. Each vent to be equipped with an exterior louver for optimum airflow and preclusion of bird and animal entry. Electrical System Provide a pre-wired electrical system including necessary breaker panel, relays, and switches. All interior electrical components must be rated for class 1, division 1 or division 2, subtle for hazardous locations. Pre-wired electrical systems to include one exterior NEMA 3R load center with appropriate circuit breakers. Grounding Provide interior and exterior grounding lugs to building. Exterior optional – grounding kit with ½” dia. X 8’ long copper plated ground rod, ½” dia. Copper alloy rod clamp, and 10’ - #6 bare copper wire. Conforms to OSHA requirements 1910.106. Building to be grounded per local building codes. Interior Lighting Provide interior hazardous location ceiling mount incandescent light fixture with a 150- watt lamp rated for Class I Groups C & D, Division I. Light to have heavy-duty glass with seated heavy aluminum housing and equipped with protective metal guard. Light to be activated by one exterior light switch suitable for outdoor locations. 120 volt, 1.25 amps UL Listed. Shall be equipped with explosion relief system: Pressure-relief mechanism compliant with hazardous storage of class 1 fuels. Non-relieving portions of the building must be designed to resist an internal pressure of 100 pounds per square feet (psf). A minimum of one explosion relief panel to be located on rear wall of the building to mitigate -- 2 of 4 -- structural damage. Panel to be designed to release at a maximum internal pressure of 20 pounds per square foot (psf). Total panel vent open area to be minimum of one square foot per each 50 cubic feet of interior volume of the building. Vent opening to be equipped with expanded metal to preclude unauthorized entry. Tethered to building to prevent projection during explosion. 2-Hour Fire-Rated Construction: Fire-resistant construction with minimum 2-hour fire rating. Shall include freight delivery to Copper Center, Alaska Statement of Work (SOW) The contractor shall provide and deliver two hazardous material storage buildings meeting the minimum dimensional and technical specifications contained in this document. The contractor shall submit shop drawings and technical data for Government approval before fabrication. Technical Requirements • Minimum dimensions: 8 ft 3 in height (minimum), 26 ft width (minimum), and 8 ft depth (minimum). • Double-wall steel construction with airspace separation. • Integrated spill containment sump with minimum capacity of 700 gallons. • Mechanical or natural ventilation compliant with hazardous storage codes. • Secure personnel or equipment doors with locking mechanisms. • Compliance with NFPA 30, OSHA standards, and EPA hazardous storage requirements. • UL/NEC compliant electrical systems where applicable. • Exterior finish resistant to corrosion and harsh environment exposure. Delivery The contractor shall deliver the completed hazardous material storage buildings to the Copper Center, AK facility. Delivery shall occur within the negotiated timeframe. The contractor is responsible for all transport coordination and permits. DELIVERY ADDRESS: WRANGELL ST ELIAS NATIONAL PARK MILE

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Similar Active Opportunities (NAICS 332311)