RFI - TRANE Chiller Servicing at Buckley Space Force Base

DEPT OF DEFENSE

Notice type
Sources Sought
Solicitation #
TRANEChillerServicing
NAICS
238220
PSC
J041
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
July 17, 2026
Response due
July 24, 2026
Place of performance
Aurora, CO

What this opportunity is

The Department of Defense is seeking a contractor to provide servicing for two 200 Ton Air-Cooled Trane Chillers at Buckley Space Force Base in Colorado. This opportunity is set aside for Total Small Businesses under NAICS 238220, which covers specialty trade contractors for heating and air conditioning. Interested businesses should note that this is a Sources Sought notice, indicating they should track the opportunity rather than submit bids at this stage, as the government is gathering information on potential contractors.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

1. DISCLAIMER This Sources Sought is for informational and market research purposes only. It does not constitute a Request for Proposal (RFP), Request for Quotation (RFQ), or a promise to issue a solicitation in the future. This notice does not commit the Government to contract for any supply or service whatsoever. Furthermore, the Government is not at this time seeking proposals and will not accept unsolicited proposals. Responders are advised that the Government will not pay for any information or administrative costs incurred in response to this Sources Sought; all costs associated with responding to this notice will be solely at the interested party’s expense. 2. PURPOSE The Department of the Air Force, Space Force, 460th Contracting Squadron (460 CONF) at Buckley Space Force Base (SFB), Colorado, is conducting market research to determine the availability and technical capability of qualified commercial sources, including small businesses (such as 8(a), HUBZone, Service-Disabled Veteran-Owned Small Businesses [SDVOSB], and Women-Owned Small Businesses [WOSB]), to perform inspection, software upgrade, maintenance, and recommissioning services for two (2) Air-Cooled Scroll Chillers. 3. BACKGROUND The commercial HVAC infrastructure at Building 442 (606 S. Aspen St., Buckley SFB, CO 80011) utilizes air-cooled chillers to support mission-critical facility operations. The existing units—two (2) Air-Cooled Trane Chillers, Model # CGAM120F—were originally installed in 2012. These units are currently operating on beta software and require an upgrade to the latest manufacturer production software, along with comprehensive sensor calibration, physical annual inspections, and full system recommissioning to ensure optimal operational efficiency and environmental compliance. 4. DESCRIPTION OF REQUIREMENT The contractor shall provide all fully qualified technicians, specialized tools, and equipment necessary to inspect, upgrade, and recommission two (2) Air-Cooled Trane Chillers. Key Objectives / Scope of Work include: • Manufacturer Manual Review: Thoroughly review all manufacturer Installation and Operation manuals prior to commencing on-site work. • Software & Reprogramming: Update necessary software on both chillers from beta to the current production version and re-program both chillers. • Calibration & Performance Tuning: Calibrate chiller sensors and actuators to ensure proper operation, verify that Thermostatic Expansion Valves (TXVs) are operating correctly, and adjust settings/parameters to optimize cooling performance. • Post-Upgrade Inspection: Perform a detailed physical inspection of the chillers after the software update and verify unit-to-unit communication and full system functionality. • Annual Maintenance & Leak Checks: Complete a full annual inspection, including comprehensive refrigerant leak testing and physical damage inspections. • System Safety & Operational Checks: Perform rigorous operational and safety system checks upon completion of work. • Deficiency & Recommendation Reporting: Deliver a comprehensive deficiency report detailing any compromised components. If additional repairs or a full system replacement are recommended, provide a separate, highly detailed report containing clear engineering and economic justifications. • Restricted Area (RA) Security Compliance: • No cell phones, cameras, recording devices, or Bluetooth-enabled devices are permitted into the Restricted Area (RA). • If photographs are required for reporting, the contractor must coordinate with the Civil Engineer Project Manager (PM) to have them taken in an approved manner. • For any necessary technical electronic devices, the contractor must submit the make, model, year, and purpose of the device to the Contracting Officer (CO) or Contracting Officer’s Representative (COR) for security approval prior to bringing the device into the RA. • Governing Standards: All work shall be performed in strict accordance with the manufacturer's specifications, applicable state and local codes/laws, and UFC 3-410-01: Heating, Ventilating, and Air Conditioning Systems. UFC criteria can be accessed at the Whole Building Design Guide. • Labor Qualifications: All technicians must be fully licensed and certified to service commercial HVAC/chiller systems. Technicians must possess specialized manufacturer certification and hands-on experience with Trane Model CGAM120F Air-Cooled Chillers. 5. NORTH AMERICAN INDUSTRY CLASSIFICATION SYSTEM (NAICS) The anticipated NAICS code for this requirement is 238220 - Plumbing, Heating, and Air-Conditioning Contractors, which has a small business size standard of $19.0 Million. The corresponding Product Service Code (PSC) is J041 - Maint/Repair/Rebuild of Equipment: Refrigeration, Air Conditioning, and Air Circulating Equipment. 6. REQUESTED INFORMATION Interested and capable commercial entities are invited to submit a Capability Statement. Responses should be concise and focused on the firm's ability to meet the requirements described above. Please provide the following information: A. Company Profile 1. Company Name and Address. 2. Point of Contact (Name, Title, Email, Phone Number). 3. CAGE Code and UEI Number. 4. Business Size and Socio-economic Status (e.g., Large Business, Small Business, 8(a), SDVOSB, WOSB, etc.) under NAICS code 238220. B. Technical Capabilities 5. Technical Approach: Describe your company’s technical approach and experience in executing commercial chiller software upgrades (specifically transitioning from beta to production software), sensor/actuator calibration, and recommissioning on Trane Chillers (Model # CGAM120F). 6. RA Operations Experience: Describe your firm's experience working in high-security military Restricted Areas (RA). Specifi

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Similar Active Opportunities (NAICS 238220)