What this opportunity is
NASA is seeking to purchase a Scanivalve Pressure System, specifically requiring various models of the DSA5002 pressure scanners and associated calibration equipment. This opportunity is set aside for total small businesses under NAICS 334513. Interested vendors must be authorized resellers and should note that the solicitation is a combined synopsis/solicitation, indicating that they should track the notice rather than submit a bid immediately. Bidders must include specific information in their quotes, including CAGE/UEI codes and lead times for delivery.
Analysis by Mindy, grounded in the SAM.gov notice.
Description
STATEMENT OF WORK
1. Objective/Requirements
NASA Glenn Research Center requires the purchase of a Scanivalve scanned
pressure system.
2. Characteristics, Scope, and Specs
LINE PART NO. DESCRIPTION QTY.
1 DSA5002/063T Part Number: DSA5002/063T - 5.00PSID
Description: DSA5002 Standard Differential
(Single
Reference), 16 Channel Pressure Scanner -
5.00PSID, QD
Input Header With 0.063 OD Tubulations
(PN 20009-02)
Fitting Kit
4
2 DSA5002/063T Part Number: DSA5002/063T - 15.00PSID
Description: DSA5002 Standard Differential
(Single
Reference), 16 Channel Pressure Scanner -
15.00PSID,
QD Input Header With 0.063 OD
Tubulations (PN
20009-02) Fitting Kit
4
3 DSA5002/063T Part Number: DSA5002/063T - 45.00PSID
Description: DSA5002 Standard Differential
(Single Reference), 16 Channel Pressure
Scanner - 45.00PSID, QD Input Header With
0.063 OD Tubulations (PN:20009-02) Fitting
Kit
2
3 DSA5002/063T Part Number: DSA5002/063T - 100.00PSID
Description: DSA5002 Standard Differential
(Single Reference), 16 Channel Pressure
Scanner - 100.00PSID,
QD Input Header With 0.063 OD
Tubulations (PN
20009-02) Fitting Kit
2
PDM5004 PDM5004 Power Distribution Module for up
to 4 modules
(DC Power Cables sold separately)
3
156147-01
DSA5000
156147-01 DSA5000 Power / Serial /
Trigger Cable, 10 ft long
12
156145-01
DSA5000
156145-01 DSA5000 Ethernet Cable, 10 ft
long
12
-- 1 of 5 --
SPC4050 SPC4050 2-Channel Pressure Calibrator
(SPECIAL: with
IS-33, 0.008� FS Accuracy), with internal
barometer
Channel A: Low Pressure Servo Regulator
(LPSVR)
Transducer 1: 5psig (Cal’d 5.75psig)
Transducer 2: 15psig (Cal’d 17psig)
Channel B: Medium Pressure Servo
Regulator (MPSVR)
Transducer 1: 50psig (Cal’d 56psig)
Transducer 2: 100psig (Cal’d 115psig)
1
SPC4050PLU-2 SPC4050PLU-2 Pneumatic Logic Unit, 2-
Channel (90psi
CTL)
1
70380-02 70380-02 Pneumatic Distribution Panel,
SPC4050, 2
Channel, 90 psi Control
1
73680 73680 4-Range Portable Calibration System
with items
8-10 installed. Including Pneumatic /
Electrical interface
panel, internal pneumatic and electrical
connections,
testing and documentation. REF: Sales Dwg
80068-01
1
System shall support the following pressure scanners:
Scanivalve DSA5002/ 063T – 5.00 PSID pressure scanner with the following salient
specifications:
• Scanner range: 5 psid
• Fitted with valve for purge and re-zero.
• Fitted with 0.063” bulged tubulations
• Engineering unit data stream up to 5,000Hz (Samples/Channel/Second)
• Accuracy of ±0.04% Full Scale
• Non-multiplexed, synchronous scanning
• TCP/IP communications
• 24-bit A/D converter per channel
• 0 degC to 70 degC temperature compensated range
System shall support the following pressure scanners:
Scanivalve DSA5002/ 063T – 15.00 PSID pressure scanner with the following salient
specifications:
• Scanner range: 15 psid
• Fitted with valve for purge and re-zero.
-- 2 of 5 --
• Fitted with 0.063” bulged tubulations
• Engineering unit data stream up to 5,000Hz (Samples/Channel/Second)
• Accuracy of ±0.04% Full Scale
• Non-multiplexed, synchronous scanning
• TCP/IP communications
• 24-bit A/D converter per channel
• 0 degC to 70 degC temperature compensated range
System shall support the following pressure scanners:
Scanivalve DSA5002/ 063T – 45.00 PSID pressure scanner with the following salient
specifications:
• Scanner range: 45 psid
• Fitted with valve for purge and re-zero.
• Fitted with 0.063” bulged tubulations
• Engineering unit data stream up to 5,000Hz (Samples/Channel/Second)
• Accuracy of ±0.04% Full Scale
• Non-multiplexed, synchronous scanning
• TCP/IP communications
• 24-bit A/D converter per channel
• 0 degC to 70 degC temperature compensated range
System shall support the following pressure scanners:
• Scanivalve DSA5002/ 063T – 100.00 PSID pressure scanner with the following
salient specifications:
• Scanner range: 100 psid
• Fitted with valve for purge and re-zero.
• Fitted with 0.063” bulged tubulations
• Engineering unit data stream up to 5,000Hz (Samples/Channel/Second)
• Accuracy of ±0.04% Full Scale
• Non-multiplexed, synchronous scanning
• TCP/IP communications
• 24-bit A/D converter per channel
• 0 degC to 70 degC temperature compensated range
System shall support the following power distribution module:
Scanivalve PDM5004 with the following salient specifications:
• Provides DC power for multiple Scanivalve devices
• 4 output channels
• 110-220 VAC 50-60 Hz (90-264VAC)
• 24VDC per output
• 0 to 60°C temperature operation range (95% typ. efficiency)
• Desktop or rack-mountable
-- 3 of 5 --
System shall support the following cables:
Scanivalve 156147-01 with the following salient specifications:
• For use with Scanivalve DSA5002 pressure scanner and PDM5004 power
distribution module
• Provides power, serial, and trigger signal
• 10 ft. length
Scanivalve 156145-01 with the following salient specifications: For use with Scanivalve
DSA5002 pressure scanner
• Provides ethernet communications
• 10 ft. length
System shall support the following pressure controller/ calibrator:
Scanivalve SPC4050 with the following salient specifications:
• ChA and ChB transducers - IS-33, 0.008% FS Accuracy
• Internal barometer channel
• Channel A: Low Pressure Servo Regulator (LPSVR) Transducer 1: 5psig (Cal
5.75psig)
• Transducer 2: 15psig (Cal 17psig)
• Channel B: Medium Pressure Servo Regulator (MPSVR) Transducer 1: 50psig
(Cal 56psig)
• Transducer 2: 100psig (Cal 115psig)
• Removeable/ Interchangeable transducers
• Color touch screen
• Used for automated DSA5002 calibrations
• Bench or rack-mount
System shall support the following pneumatic logic unit:
Scanivalve SPC4050PLU-2 Pneumatic Logic Unit with the following salient
specifications:
• 2 – channel, 90 psi control pressure
• Positive or below atmospheric (vacuum) calibrations
• Zero offset correction logic
• Leak and response testing on pressure scanners
System shall support the following pneumatic distribution panel:…
Source: SAM.gov, as posted. Verify the current solicitation before responding.