22 MXS - Power Pitts & Jet Power Unit Troubleshooting - McConnell AFB
DEPT OF DEFENSE
Notice type
Solicitation
Solicitation #
FA462126Q0037
NAICS
238210
PSC
J059
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
July 27, 2026
Response due
August 11, 2026
Place of performance
PRAIRIE VLG, KS
Description
1
27 July 2026
Statement of Work
Power Pits
McConnell AFB, Kansas
1. Overview
1.1 The 22nd MXG requires troubleshooting, identification of inoperability, and writing of
report regarding the Power Converter and Power Pit assembly in buildings 1125,
1126 center bay, and 1124 south bay. All applicable units are currently non-
functional.
1.2 Building 1125 is believed to have a damaged track motor or the tracks themselves
responsible for raising and lowering the power pit.
1.3 Building 1126 Center Bay is believed to lose power somewhere between the wall
unit and the pit.
1.4 Building 1124 South Bay is believed to have damaged / faulty track or motor. Power
Pit has been mechanically locked in the up position for usability.
2. Description
2.1 The following Part Numbers and accessories (cables to/from) are subject to troubleshoot.
Power Pit
Model: USS24S(12)-20X20-32X32-60D-400Hz(30)
Jet Power
Part: 2913670.17BLU1
Model: JTP3 Plus 180KVA/480V/60HZ
DESCRIPTION OF SERVICES: The contractor shall provide all management, tools, supplies,
equipment, and labor necessary to troubleshoot the equipment and provide a detailed report.
-- 1 of 11 --
2
PERIOD OF PERFORMANCE:
The performance period for this contract shall be no later than more than 45 days after award of the
contract. A weekly status update is required.
3. SPECIFIC REQUIREMENTS
3.1.
4. WORKING AREA
4.1. Power Pits are located in 1124S, 1125, and 1126C. 1126N and 1126S have power pits that are
fully operational and can be inspected for comparison.
5. GENERAL INFORMATION:
5.1. Security
5.1.1. Removing objects from refuse for personal use is unauthorized. Contractor
Personnel may request items through unit designee. Violations are grounds for
termination.
5.1.2. Contractor shall adhere to current installation security policies.
5.2. On-site Project Installation Support Hours:
3.1. The following requirements have been identified for operations of McConnell AFB.
The Contractor shall furnish the necessary personnel, labor, supervision, tools, and
troubleshooting equipment required to diagnose, test, and resolve operational issues. All testing
and diagnostic supplies will be provided by the contractor unless specified in the sections below.
Contractor shall keep in effect all necessary permits, licenses, and insurance. All troubleshooting
work shall be completed in accordance with all federal, state, and local regulations and the
terms and conditions of this Statement of Work (SOW).
-- 2 of 11 --
3
5.2.1. Contractor Personnel shall be readily available during normal duty hours at the
site, Monday through Friday, from 0700-1600. Concessions are made for
religious holidays, at the discretion of the US, when it does not interfere with
operations.
5.3. Emergency Services:
5.3.1. On occasion, services may be required to support an activation or exercise of
contingency plans outside the normal duty hours described above.
5.4. Standards of Conduct:
5.4.1. Contractor Personnel must adhere to standards of conduct as established by the
Installation Commander.
5.5. Records:
5.5.1. Developed and provided at the start of the orientation period or the start of the
first operational performance period (if there is no orientation period) a safety
plan for the protection of government facilities and property and to provide a safe
work environment for contractor personnel.
5.6. Access to Project Site:
5.6.1. The contractor will coordinate troubleshooting arrangements within 5 days of performance
with the Corrosion Control section.
5.7. Contractor Quality Assurance:
5.7.1. The contractor shall be responsible for the quality of all completed work. The
contractor shall ensure all work performed has been checked for quality and
accuracy.
6. GOVERNMENT FURNISHED PROPERTY (GFP) AND SERVICES:
6.1. The US Government will not provide any equipment, fuel, personnel, utilities or
facilities to the contractor for the execution of this contract. Should an emergency arise,
only the necessary basic lifesaving and life support measures will be provided during the
emergency.
6.2. Safety: The contractor shall comply with all base fire, safety and confined space regulations
while completing their install.
6.3. Duty Hours: Work will be accomplished while building is occupied. Normal Hours of Operation
for this contract are between the hours of 0700 to 1600 hours local Monday through Friday. The
-- 3 of 11 --
4
contractor shall perform the services required under this contract during this time excluding
Saturdays, Sundays, Wing down days and Federal Holidays.
6.4. Contractor Consent to Background Checks: The contractor and, as applicable, subcontractor
shall not employ persons for work on this contract if such employee is identified as a potential
threat to the health, safety, security, general well-being or operational mission of the installation
and its population, nor shall the contractor or subcontractor employ persons under this contract
who have an outstanding criminal warrant as identified by the National Crime Information
Center (NCI). NCI checks will verify if a person is wanted by local, state, and federal agencies. All
contractor and subcontractor personnel must consent to NCI background checks. Contractor
and subcontractor personnel who do not consent to a NCI check will be denied access to the
installation. Information required conducting a NCI check includes: your full name, address, and
social security number, date of birth, driver’s license number and state and completion of a
background check questionnaire. The contractor shall provide this information using the
McConnell AFB Form 114, Contractor/Vendor Access List, and shall submit it in conjunction with
the contractor’s request for either base or vehicle passes. Completion of a successful NCI check
does not invalidate the requirement for an escort when contractor or subcontractor personnel
are working within controlled or restricted areas.
6.5. Compensation: The contractor shall not be entitled to any c…
Source: SAM.gov, as posted. Verify the current solicitation before responding.
Pursue this opportunity with Mindy
See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.
View the original notice on SAM.gov ↗Similar Active Opportunities (NAICS 238210)
Insulation Resistance Testing Services
DEPT OF DEFENSE · Combined Synopsis/Solicitation · due August 10, 2026
US Coast Guard Air Station Savannah Generator
HOMELAND SECURITY, DEPARTMENT OF · Combined Synopsis/Solicitation · due August 19, 2026
ELECTRICAL WORK
DEPT OF DEFENSE · Combined Synopsis/Solicitation · due August 20, 2026