What this opportunity is
The Department of Commerce is seeking a contractor to provide an advanced multichannel multispectral photodetection system for integration into its Serial Flow Cytometer, which is used for high-resolution optical measurements of biological micro and nanoparticles. This opportunity is open to all businesses as there is no set-aside. The notice type is a Combined Synopsis/Solicitation, indicating that interested parties should track the opportunity closely for further details rather than submit immediate bids.
Analysis by Mindy, grounded in the SAM.gov notice.
Description
STATEMENT OF WORK/REQUIREMENTS DOCUMENT
Title: Procurement of Advanced Photodetector System
Requesting Lab: PML / 681
I. BACKGROUND INFORMATION
The National Institute of Standards and Technology (NIST), Biophysical and Biomedical Measurement
Group (BBMG) within the Microsystems and Nanotechnology Division of the Physical Measurement
Laboratory (PML) requires an advanced spectral photodetection system for incorporation into NIST’s
unique and world-class Serial Flow Cytometer for high temporal and spectral resolution optical
measurements of biological micro and nanoparticles. This will enable accomplishment of our mission of
developing microscale measurement science and technology applied to characterization of biological
systems.
Flow cytometry is a technology that rapidly analyzes properties of thousands of single cells or particles
per second as they flow in a fluid stream. A laser incident on the fluid stream interrogates the cells, which
can be labeled with fluorescent markers to enable the quantification of specific cell markers and
classification of different cell types within populations. NIST develops a Serial Flow Cytometer (SFC)
that uses multiple light sources to repeat optical measurements of single cells to provide uncertainty
quantification (UQ). UQ is a valuable outcome that enables optimization of flow cytometers and
modeling to improve confidence in flow cytometry measurements and instrument comparability.
Purpose/Objective: NIST requires a complete, multichannel and multispectral photodetector system as
listed below in the Scope and specified below in Minimum Requirements. The system will integrate
directly into NIST’s Serial Flow Cytometer to perform sensitive, dynamic, and hyperspectral fluorescence
measurements of rapidly flowing micro and nanoparticles including cells, gene therapy nanoparticles, and
fluorescence calibration particles. Incorporation of the system within NIST instruments requires
compatible connections to optical lines and routing of voltage signals to NIST recording devices.
The advanced photodetector system is critical to achieve NIST project missions as it will enable the R&D
team to build generalizable, multimodal cytometric tools with world-class deep spectral probing to
advance Critical and Emerging Technologies (CETs) in Biotechnology. Since the advanced photodetector
system is needed to conduct preliminary experiments to guide microdevice development, it must be
awarded in FY26.
II. SCOPE
The Contractor shall deliver an advanced multichannel multispectral photodetection system that meets the
specifications described within this document, including warrantied hardware. The contractor is also
responsible for providing installation instructions and facilitating initial training and troubleshooting of
the system either in-person or remotely.
III. MINIMUM REQUIREMENTS
The Contractor shall provide a system that meets all technical specifications identified below. All items
must be new. Used or remanufactured equipment will not be considered for award. Experimental,
prototype, or custom items will not be considered. The use of “gray market” components are not
authorized for sale in the U.S. by the Contractor is not acceptable. All line items shall be shipped in the
original manufacturer’s packaging and include all original documentation and software, when applicable.
Line Item 0001:
Description: Advanced Spectral Photodetector System
Quantity: 1
-- 1 of 5 --
A. Technical Specifications
a. Performs multispectral light detection with ≥ 16 spectral channels, each detecting a non-
overlapping wavelength bin of bin width ≤ 20 nm, distributed over a spectral sensitivity
range including ≤ 450 nm to ≥ 750 nm.
b. Detects light from ≥ 4 light sources, either through multiplexed detection to one system
unit or through separated detection to multiple detector modules
c. Accepts one fiber optic input per light source (SMA905 connector, fiber NA ≥ 0.1 and
core diameter ≥ 105 μm)
d. Internal detector format: photomultiplier tube, avalanche photodiode, silicon
photomultiplier, or hybrid
e. Typical peak photon detection efficiency ≥ 10 %, net bandwidth ≥ 500 kHz, Readout
noise ≤ 10 mV p-p, and Dynamic range ≥ 10,000
f. Max voltage output with 500 mV ≤ max output ≤ 10 V and per-channel standard
connector (i.e., SMA or BNC) to differential digitizers
g. Includes power supply and tunable amplification gain via provided hardware or (if
needed) via computer control
h. Gain range for resolving fluorescence intensities between ≤ 102 MESF and ≥ 105 MESF
Line Item 0002:
Description: Installation/training
Quantity: 1
A. Technical Specifications
a. Instructions for installation, validation, and training must be provided.
b. Remote or in-person meeting(s) will meet this requirement.
Line Item 0003:
Description: Shipping / Receiving
Quantity: 1
A. Technical Specifications
a. The cost for shipping and receiving to NIST Gaithersburg, MD, must be provided.
IV. DELIVERABLES
Description Quantity or Format Due Date
Spectral photodetector system
meeting the specification described
above
Physical instrument consisting of one or
more photodetector modules.
12 weeks after
award
Operations and maintenance
manual for the system covering
proper operation, routine
maintenance, and troubleshooting
for the instrument
Electronic (.pdf) or paper copies At the same time
as delivery
Standards of Acceptance: The NIST TPOC or COR shall review that the unit is functioning to
specifications as outlined in Section III and respond with an acceptance or request for revision
email to the Contractor Point of Contact (POC) within 2 months of receipt of deliverable. This
-- 2 of 5 --
section applies to deliverables which must be reviewed and approved for acceptances (draft plans,
drawings, etc.)
V. PLACE OF PERFORMANCE
a) Construction and fabrication of the equipment shall be completed at the contractor’s facility.
b) If necessary (i.e., if remote installation cannot be achieved), instal…
Source: SAM.gov, as posted. Verify the current solicitation before responding.