Combo - FY26 Wargamming Secure (Vault) Door
DEPT OF DEFENSE
Notice type
Combined Synopsis/Solicitation
Solicitation #
FA330026Q2001
NAICS
332321
PSC
5670
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
July 20, 2026
Response due
July 31, 2026
Place of performance
Montgomery, AL
Description
STATEMENT OF REQUIREMENT
SECURE DOOR FOR SAPCA
1.0 SUMMARY OF REQUIREMENT. The vault on the first floor of bldg. 1406 is being re-
purposed as a Special Access Program Compartmented Area (SAPCA) discussion room. The vault
door has been removed and a new secure door needs to be framed and installed.
2.0 DESCRIPTION OF REQUIREMENT. In accordance with DoDM 5205.07, the SAPCA
door will be accessed by mechanical or electronic access control devices only. Spin-dial combo
locks are prohibited. The acoustic rating must meet the same STC requirements as the Secure
Compartmented Information Facility (SCIF). The door must be opaque and must be compatible with
automated access control for unescorted entry.
Door must have an STC rating of 45 or 50. Door dimensions will fit the current opening that is
roughly 48”W x 81.5”H. Any gaps left around the door frame after install will need to be filled to
the specifications/requirements listed in ICD 705. In accordance with DoDM 5205.07, the door will
be accessed by mechanical or electronic access control devices only. Spin-dial combo locks are
prohibited. The acoustic rating must meet the same STC requirements as the Secure Compartmented
Information Facility (SCIF). Steel Door must have an STC rating 45 or 50. Modification to the
current door frame is required. If current frame needs to be removed for the new door to be installed
properly, all modifications will adhere to the requirements outlined in ICD 705 Tech Spec. The door
dimensions will be fitted to the current opening that is roughly 48”W x 81.5”H. 1 ¾ inch-thick face
steel equal to minimum 18-gauge steel, hinges reinforced to 7-gauge steel and preferably a lift
hinge, door closure installation reinforced to 12-gauge steel. The door must be opaque and must be
compatible with automated access control for unescorted entry to include any damages to sheetrock
and/or gaps around the door will be repaired to the specifications and requirements listed IAW ICD
705 Tech Spec.
3.0 GENERAL INFORMATION.
Location: LeMay Center/WA, 401 Chennault Circle, Bldg 1406, Maxwell AFB AL 36112.
OMBUDSMAN
(a) An ombudsman has been appointed to hear and facilitate the resolution of concerns from
offerors, potential offerors, and others for this acquisition. When requested, the ombudsman will
maintain strict confidentiality as to the source of the concern. The existence of the ombudsman does
not affect the authority of the program manager, contracting officer, or source selection official.
Further, the ombudsman does not participate in the evaluation of proposals, the source selection
process, or the adjudication of protests or formal contract disputes. The ombudsman may refer the
interested party to another official who can resolve the concern.
(b) Before consulting with an ombudsman, interested parties must first address their concerns,
issues, disagreements, and/or recommendations to the contracting officer for resolution. Consulting
an ombudsman does not alter or postpone the timelines for any other processes (e.g., agency level
bid protests, GAO bid protests, requests for debriefings, employee-employer actions, contests of
OMB Circular A-76 competition performance decisions).
(c) If resolution cannot be made by the contracting officer, the interested party may contact the
ombudsman, Primary: Mr. David E. Jones, Deputy Director of Contracting, AFICC/KT (OL-AET),
-- 1 of 3 --
Telephone Numbers: (210) 652-1722 (DSN: 487-1722); or Alternate: Mr. Todd S. Joyner, Chief,
Clearance & Program Support Division, Telephone Number: (210) 652-7075 (DSN: 487-7075).
Address: 2035 First Street West, JBSA Randolph TX 78150-4304. E-mail Addresses:
david.jones.3@us.af.mil and todd.joyner@us.af.mil. Concerns, issues, disagreements, and
recommendations that cannot be resolved at the Center/MAJCOM/DRU/SMC ombudsman level,
may be brought by the interested party for further consideration to the Air Force ombudsman,
Associate Deputy Assistant Secretary (ADAS) (Contracting), SAF/AQC, 1060 Air Force Pentagon,
Washington DC 20330-1060, phone number (571) 256-2395, facsimile number (571) 256-2431.
(d) The ombudsman has no authority to render a decision that binds the agency.
(e) Do not contact the ombudsman to request copies of the solicitation, verify offer due date, or
clarify technical requirements. Such inquiries shall be directed to the contracting officer.
CONTRACTOR ACCESS TO AIR FORCE INSTALLATIONS
(a) The contractor shall obtain base identification and vehicle passes, if required, for all contractor
personnel who make frequent visits to or perform work on the Department of the Air Force
installation(s) cited in the contract. Contractor personnel are required to wear or prominently display
installation identification badges or contractor-furnished, contractor identification badges while
visiting or performing work on the installation.
(b) The contractor shall submit a written request on company letterhead to the contracting officer
listing the following: contract number, location of work site, start and stop dates, and names of
employees and subcontractor employees needing access to the base. The letter will also specify the
individual(s) authorized to sign for a request for base identification credentials or vehicle passes. The
contracting officer will endorse the request and forward it to the issuing base pass and registration
office or Security Forces for processing. When reporting to the registration office, the authorized
contractor individual(s) should provide a valid driver's license, current vehicle registration, valid
vehicle insurance certificate, and all appliable base regulations to obtain a vehicle pass.
(c) During performance of the contract, the contractor shall be responsible for obtaining required
identification for newly assigned personnel and for prompt return of credentials and vehicle passes
for any employee who no longer requires access to the work site.
(d) When work under this contract requires unescorted entry to c…
Source: SAM.gov, as posted. Verify the current solicitation before responding.
Pursue this opportunity with Mindy
See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.
View the original notice on SAM.gov ↗Similar Active Opportunities (NAICS 332321)
786 FSS Fitness Center Doors
DEPT OF DEFENSE · Presolicitation · due August 7, 2026
JOINER DOORS
DEPT OF DEFENSE · Solicitation · due July 22, 2026
Replacement of the Roll-up Garage Doors for Government Owned Houses (GOH)
STATE, DEPARTMENT OF · Solicitation · due August 18, 2026
20--WINDOW,MARINE
DEPT OF DEFENSE · Combined Synopsis/Solicitation · due July 27, 2026
30--CONNECTING LINK,RIG
DEPT OF DEFENSE · Combined Synopsis/Solicitation · due July 27, 2026
Z1DA--Automatic Opposing Swing Doors - Building 1, E-Wing Questions & Answers
VETERANS AFFAIRS, DEPARTMENT OF · Combined Synopsis/Solicitation · due July 10, 2026