DILLON FIELD OFFICE CATTLE GUARD

INTERIOR, DEPARTMENT OF THE

Notice type
Solicitation
Solicitation #
140L3626Q0033
NAICS
332312
PSC
9520
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
June 12, 2026
Response due
June 26, 2026

What this opportunity is

The Department of the Interior is seeking a contractor to supply cattleguards for the Bureau of Land Management's Dillon Field Office in Montana. This opportunity is set aside for total small businesses under FAR 19.5, making it suitable for small contractors in the steel fabrication sector (NAICS 332312). Interested bidders should note that this is a solicitation notice, indicating that they will need to prepare and submit a bid rather than merely tracking the opportunity.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

Dillon Field Office Cattleguards BUREAU OF LAND MANAGEMENT 1005 Selway Drive Dillon, Montana 59725 March 4, 2026 -- 1 of 4 -- DILLON FIELD OFFICE CATTLEGUARDS TABLE OF CONTENTS TABLE OF CONTENTS DFO CATTLEGUARDS 1 SPECIFICATIONS PAGE NO. STATEMENT OF WORK .......................................................................................... 1 - 2 DRAWINGS PAGE NO. LOCATION MAP...................................................................................................... 1 of 4 CATTLEGUARD GRID ........................................................................................... 2 of 4 CATTLEGUARD BASE ........................................................................................... 3 of 4 CATTLEGUARD WINGS ....................................................................................... 4 of 4 -- 2 of 4 -- DFO CATTLEGUARDS STATEMENT OF WORK STATEMENT OF WORK DFO CATTLEGUARDS 1 GENERAL STATEMENT: This contract is to fulfill the Dillon Field Office (DFO) need for Cattleguards. The Bid Value Schedule will provide quantities and lengths of cattleguards as required by this contract. The Contractor awarded this contract is responsible for delivery of the materials to the BLM Admin Site located at 1005 Selway Drive, Dillon Mt. 59725. At the BLM site, BLM will provide forklift and operator for off-loading materials. REQUIRED FEATURES – CATTLEGUARD GRID: *All steel components shall be ASTM A-36, unless indicated otherwise on the drawings. *Design load of Grid shall conform to AASHTO HS-20. *Steel Grids shall be all-welded construction. Welds shall be secure and complete along both edges of cross pieces and at joints in the frame, and conform to AWS D1.1. *Rails shall be solid continuous members; they shall not have butt welds. *Paint: Structural steel shall be cleaned according to SSPC SP-6. Cattleguards Grids and end wings shall each receive a prime coat and finish coat. The prime coat shall be a lead free, zinc- rich, rust-inhibitive alkyd metal primer. Minimum thickness shall be 1-1/2 mils dry-film thickness. The finish coat shall be an oil alkyd-enamel, gloss paint. Minimum thickness shall be 3MIL dry film thickness, applied in two applications. *Paint color shall be federal safety yellow or match color No. 13655, FED specification TT-C- 595. Cattleguards and wings shall be painted after fabrication. *Manufacturer’s Literature: Submit 2 copies of the manufacture’s descriptive data including design data for commercial cattleguards grids. *Certificates: Submit 2 copies of written certification from the supplier that the cattleguards conform to the requirements as shown on the drawings and stated in the specification notes. REQUIRED FEATURES – CATTLEGUARD BASES: *Bases shall be of precast concrete with 3,000 psi, 28 day compressive strength. Concrete shall be smooth finished, and free of voids, excessive honeycomb, or other imperfections. *Each base will have at least one lift eye set into the face, welded to the rebar, for lifting the base. -- 3 of 4 -- STATEMENT OF WORK DFO CATTLEGUARDS 2 *Each end of each base will have two ½” threaded anchor bolts extending 4” from the base, for attaching side boards. Anchor bolts will be 3” and 9” from the top of the base, and centered into the upright part of the base. * Each base will be 3” longer than its nominal size, i.e., 12’ bases will measure 12’ 3”, 14’ bases will measure 14’3”, and 16’ bases will measure 16’3”. REQUIRED FEATURES – CATTLEGUARD WINGS: * All steel components shall be ASTM A-36, unless indicated otherwise on the drawings. *Cattleguard wings shall be all welded construction, welds shall be secure and complete. * Paint: Structural steel shall be cleaned according to SSPC SP-6. Cattleguards Grids and end wings shall each receive a prime coat and finish coat. The prime coat shall be a lead free, zinc- rich, rust-inhibitive alkyd metal primer. Minimum thickness shall be 1-1/2 mils dry-film thickness. The finish coat shall be an oil alkyd-enamel, gloss paint. Minimum thickness shall be 3MIL dry film thickness, applied in two applications. *Paint color shall be federal safety yellow or match color No. 13655, FED specification TT-C- 595. Cattleguards and wings shall be painted after fabrication. *Manufacturer’s Literature: Submit 2 copies of the manufacture’s descriptive data including design data for commercial cattleguards grids. *Certificates: Submit 2 copies of written certification from the supplier that the cattleguards conform to the requirements as shown on the drawings and stated in the specification notes. -- 4 of 4 --

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Similar Active Opportunities (NAICS 332312)