FIRE SUPPRESSION SUPPORT

DEPT OF DEFENSE

Notice type
Solicitation
Solicitation #
N40085-26-R-0052
NAICS
561621
PSC
H242
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
May 21, 2026
Response due
May 27, 2026
Place of performance
Camp Lejeune, NC

What this opportunity is

The Department of Defense is seeking a contractor to provide fire suppression support services, including annual testing and maintenance programs for various fire detection and suppression systems across multiple buildings in North Carolina. This opportunity is set aside for total small businesses under NAICS 561621. Interested small businesses should note that the notice type is a solicitation, indicating that they can submit proposals rather than simply tracking the opportunity.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

BASE YEAR (FFP) PROPOSAL PRICING SOLICITATION/CONTRACT N40085-26-R-0025 Provide Pricing to Maintain Fire Suppression and Pump Services for the Firm Fixed Price for recurring Spec Items in accordance with Section C, Spec Item 3. ELIN / Sub ELIN Description Quantity Freq Unit of Issue Unit Price Total Building - AS256 (BASE) A00101 Implememt Annual Testing on Monitored Fire Detection and Alarm Systems. 1 A EA A00102 Implememt Annual Testing on Wet Pipe Sprinkler Systems. 1 A EA A00103 Implememt Annual Testing on Pre-Action Automatic Sprinkler Systems. 1 A EA A00104 Implement Annual Testing on Clean Agent Systems. 1 A EA A00105 Develop and Implement a Routine Intergrated Maintenace Program on Fire Detection and Alarm Systems. 1 A EA A00106 Develop and Implement a Routine Intergrated Maintenace Program on Wet Pipe Sprinkler Systems. 1 A EA A00107 Develop and Implement a Routine Intergrated Maintenace Program on a Pre-Action Automatic Sprinkler Systems. 1 A EA A00108 Develop and Implement a Routine Intergrated Maintenace Program on Clean Agent Systems. 1 A EA Building - AS320 Simulator (BASE) A00109 Implement Annual Testing on Monitored Fire Detection and Alarm Systems. 1 A EA A00110 Implement Annual Testing on Wet Pipe Sprinkler Systems. 1 A EA A00111 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems. 1 A EA A00112 Implement Annual Testing on Carbon Dioxide Systems. 1 A EA A00113 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems. 1 A EA A00114 Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems. 1 A EA A00115 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems. 1 A EA A00116 Develop and Implement a Routine Integrated Maintenance Program on a Carbon Dioxide Systems. 1 A EA Building - TC755 (BASE) A00117 Implement Annual Testing on Monitored Fire Detection and Alarm Systems. 1 A EA A00118 Implement Annual Testing on Clean Agent Systems. 1 A EA A00119 Implement Annual Testing on Fire and Smoke Barrier Opening Protection. 1 A EA A00120 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems. 1 A EA A00121 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems. 1 A EA A00122 Develop and Implement a Routine Integrated Maintenance Program on Fire and Smoke Barrier Opening Protection. 1 A EA -- 1 of 43 -- BASE YEAR (FFP) PROPOSAL PRICING SOLICITATION/CONTRACT N40085-26-R-0025 Building - 895 (BASE) A00123 Implement Annual Testing on Monitored Fire Detection and Alarm Systems. 1 A EA A00124 Implement Annual Testing on Wet Pipe Sprinkler Systems. 1 A EA A00125 Implement Annual Testing on Clean Agent Systems. 1 A EA A00126 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems. 1 A EA A00127 Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems. 1 A EA A00128 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems. 1 A EA Building - BB248 (BASE) A00129 Implement Annual Testing on Monitored Fire Detection and Alarm Systems. 1 A EA A00130 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems. 1 A EA A00131 Implement Annual Testing on Clean Agent Systems. 1 A EA A00132 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems. 1 A EA A00133 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems. 1 A EA A00134 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems. 1 A EA Building- FC307 (BASE) A00135 Implement Annual Testing on Monitored Fire Detection and Alarm Systems. 1 A EA A00136 Implement Annual Testing on Clean Agent Systems. 1 A EA A00137 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems. 1 A EA A00138 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems. 1 A EA Building - H1 (BASE) A00139 Implement Annual Testing on Monitored Fire Detection and Alarm Systems. 1 A EA A00140 Implement Annual Testing on Wet Pipe Sprinkler Systems. 1 A EA A00141 Implement Annual Testing on Dry Pipe Automatic Sprinkler Systems. 1 A EA A00142 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems. 1 A EA A00143 Implement Annual Testing on Clean Agent Systems. 1 A EA A00144 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems. 1 A EA A00145 Develop and Implement a Routine Integrated Maintenance Program on Wet Pipe Sprinkler Systems. 1 A EA A00146 Develop and Implement a Routine Integrated Maintenance Program on Dry Pipe Automatic Sprinkler Systems. 1 A EA A00147 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems. 1 A EA A00148 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems. 1 A EA -- 2 of 43 -- BASE YEAR (FFP) PROPOSAL PRICING SOLICITATION/CONTRACT N40085-26-R-0025 Building - HP5 (BASE) A00149 Implement Annual Testing on Monitored Fire Detection and Alarm Systems. 1 A EA A00150 Implement Annual Testing on Pre-Action Automatic Sprinkler Systems. 1 A EA A00151 Implement Annual Testing on Clean Agent Systems. 1 A EA A00152 Develop and Implement a Routine Integrated Maintenance Program on Fire Detection and Alarm Systems. 1 A EA A00153 Develop and Implement a Routine Integrated Maintenance Program on a Pre-Action Automatic Sprinkler Systems. 1 A EA A00154 Develop and Implement a Routine Integrated Maintenance Program on Clean Agent Systems. 1 A EA Building - M165 (BASE) A00155 Implement Annual Testing on Monitored Fire Detection and Alarm Systems. 1 A EA A00156 Implement Annual Testin

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Similar Active Opportunities (NAICS 561621)