Removal and Recycling of Storage Sheds

COMMERCE, DEPARTMENT OF

Notice type
Solicitation
Solicitation #
1333MF26Q0047
NAICS
238990
PSC
P100
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
June 10, 2026
Response due
June 19, 2026

What this opportunity is

The Department of Commerce is seeking a contractor for the removal and recycling of five steel storage sheds located at the NOAA Inouye Regional Center on Ford Island, Pearl Harbor. This opportunity is set aside for total small businesses under NAICS 238990, suitable for firms experienced in hazardous material handling and demolition. Interested contractors should note that this is a solicitation notice, indicating a need for tracking the proposal submission process rather than simply monitoring for bids.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

Appendix 1: Steel Storage Sheds To be Removed from NOAA Inouye Regional Center (Updated 6/7/2026) The five storage sheds to be removed are numbered in this schematic depicting the current laydown area at NOAA Inouye Regional Center on Ford Island, Pearl Harbor. Descriptions and photos of each storage shed follow. #1: Former Hazmat shed (equipped with Wall A/C) - Gov Property Dimensions: 16'1" X 9'3" X 8'8" High Exterior Automatic Fire Suppression System with Manual Pull Station tied to Alarm Bell (system to be disarmed & pressurized gas cylinder removed by NOAA prior to haul away) Not bolted to concrete pad. Not powered on site. #2: Former Hazmat Shed (equipped with Wall A/C) - Gov Property Chem-Stor (Ideal Environmental Products), 2010 Dimensions: 14'6" X 8'6" X 9’ High Exterior Automatic Fire Suppression System with Manual Pull Station tied to Alarm Bell (system to be disarmed & pressurized gas cylinder removed by NOAA prior to haul away) Bolted to concrete pad (nuts will be removed by NOAA prior to haul away) 240v power will be disconnected by NOAA prior to haul away. #3: Former Hazmat Shed (Wall A/C will be removed by NOAA prior to haul away) - Gov Property Chem-Stor (Ideal Environmental Products), 2003 Dimensions: 16'6" X 9'6" X 9’ High Exterior (est. 18K lbs) 4 Hour Fire Rated Includes wire shelving storage racks. Bolted to concrete pad (nuts will be removed by NOAA prior to haul away) 240v power will be disconnected by NOAA prior to haul away. #4: Former Hazmat Shed (equipped with Wall A/C) - Gov Property Chem-Stor (Ideal Environmental Products), 2003 Dimensions: 16'6" X 9'6" X 9' High Exterior (est. 18K lbs) 4 Hour Fire Rated Bolted to concrete pad (nuts will be removed by NOAA prior to haul away) Solar panels and equipment will be removed from roof and interior by NOAA prior to haul away. 240v power will be disconnected by NOAA prior to haul away. #5: 10ft Conex (equipped with Wall A/C) - Gov Property 10ft Conex with 4 corner posts, cargo door and roll-up door, 2017 Dimensions: 10" X 8’ X 8’6” High Exterior Electrical package: 3 outlets (including for a/c), breaker box, disconnect box Counter tops including a sink basin (might be removed by NOAA prior to haul away) Note: The Contractor will subsequently move at least one new 20ft Conex into the footprint of #3 and #4 once they are removed as part of the anticipated Phase 2 onsite relocations. #1: Former Hazmat shed (includes installed Wall A/C) #2: Former Hazmat Shed (includes installed Window A/C) #3 & #4: Former Hazmat Sheds #5: 10ft Conex

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Similar Active Opportunities (NAICS 238990)