REV-1(FO) Motor for No. One Refrigeration Plant Compressor; repair
DEPT OF DEFENSE
Notice type
Solicitation
Solicitation #
N6264926Q0473
NAICS
336611
PSC
J999
Set-aside
No Set aside used
Posted
August 7, 2026
Response due
August 10, 2026
Place of performance
Sasebo City, JP-42
What this opportunity is
The Department of Defense is seeking proposals for the repair of a motor for the No. One Refrigeration Plant Compressor aboard the USS Tripoli (LHA-7). This opportunity is open to all businesses as there is no set-aside for small businesses. Interested contractors should note that this is a solicitation notice, requiring them to submit proposals by the specified deadline in the attached solicitation documents.
Analysis by Mindy, grounded in the SAM.gov notice.
Description
Ship/HULL NO. Ship/HULL NAME ICN: Rev: Key Op:
____LHA-7 USS TRIPOLI JON. 38DJA51 605 01 AOl
TITLE: No.One Refrigeration Plant Compressor; repair
Rev-I (FO)-Motor for No.One Refrigeration Plant Compressor; repair
JOB SPECIFICATION
Anticipated Award Date Production Completion Date: PREPARING ACTIVITY:
SASEBO POP Start Date: POP End Date:
PREPARED BY:
S. NISHINO CODE
E_Nl
DATE
316/2026
APPROVED BY:
S. MURAKAMI /
7 CODE
S225
CONCURRED BY:
A. OKA CODE
S233
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
_
ASSIST PLANNER'S NAME: CODE _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
ASSIST PLANNER'S NAME: CODE
ASSIST PLANNER'S NAME: CODE
DESCRIPTION:
JSN(S): EAO5-L063 CASREP # 26026. DTG: 060336ZFEB26. C-3
S/F CONTACT: THOMAS MMC I GREEAR CWP # CCNS #
Approved by S3001S900 Date:t6'>V\4i€2 AvI: -6-At
LWC:
Work Completed
S/Force:
Ship Supt:
Rate: Date:
Date: SRF CONTROL NO.:____________________________
WORK CERTIFICATION SIGNATURES
COMPLETION OF WORK REVIEW: BADGE NO.: SHOP/CODE: PHONE: DATE:
-- 1 of 3 --
Ship/HULL NO. Ship/HULL NAME ICN: Rev: Key Op:
LHA-7 USS TRIPOLI JON. 38DJA51605 01 AOl
TITLE: No.One Refrigeration Plant Compressor; repair
Rev-1(FO)--Motor for No.One Refrigeration Plant Compressor; repair
1. SCOPE:
1.1 Title: No.One Refrigeration Plant Compressor; repair
Rev -1(FO) -Motor for No.One Refrigeration Plant Compressor; repair
1.2 Location of Work:
1.2.1 Fire Pump and REFR MCHRY Room (6-45--0-E)
1.3 Identification:
1.3.1 Quantity (One HA) No.One Refrigeration Condensing Unit located
in 1.2.1, APL: 32A060028
1.3.1.1 Quantity (One EA), Electric Motor for 1.3.1
Manufacture -
General Electric CO.
MFR DWG NO. -
225B7033
MFR ID -
5K326NS283H
Horsepower -
50 HP
Amps -
62.5 A
Speed -
1800 RPM
Volts -
440 VAC
Frequency -
60 HZ
Phase 3
Duty -
CONTINUOUS
INS CLASS -
B
APL -
175506438
2. REFERENCES:
2.1 Standard Items (FY26)
2.2 59516 -BX -MMA-010 Rev 5, Ships Stores Refrigeration Plant 5.5 Ton
Capacity Operation and Maintenance
2.3 MFR DWG. 225B7033 Rev G, Alternating Current Motor
2.4 321-7564330 Rev C, Power System 60Hz Wiring Deck Plan lB FR 49 -FWD
MDL 1
3. REQUIREMENTS:
3.1 Inspect the controller, cables and mounting hardware terminating in
electric motor listed in 1.3.1.1 for previous damage and deterioration, using
2.2 through 2.4 for guidance.
3.1.1 Verify correct value of overload setting or size of heater
coils based on motor nameplate full load running current.
CV) "REPORT"
'A
-- 2 of 3 --
Ship/HULL NO. Ship/HULL NAME ICN: Rev: Key Op:
LHA-7 USS TRIPOLI JON. 38DJA51605 01 AOl
TITLE: No.One Refrigeration Plant Compressor; repair
Rev-I (FO)-Motor for No.One Refrigeration Plant Compressor; repair
3.1.2 Submit one legible copy of condition report listing results of
the requirements of 3.1 and 3.1.1 to the SUPERVISOR.
3.2 Accomplish the requirements of 009-017 of 2.1 for the electric motor
listed in 1.3.1.1, using 2.2 through 2.4 for guidance.
3.2.1 Accomplish the requirements of 009-032 of 2.1 for cleaning and
preservation of motor housing, fan, interior and exterior of each end bell,
and foundation.
3.2.2 Accomplish the requirements of 009-015 of 2.1 for balancing of
each rotating assembly.
4. NOTES:
4.1 Initial Condition -
During normal operation watch stander noted NR 1
reefer compressor overheating. Watch stander secured NR 1 reefer, during
investigation watch stander noted freeze box temperature was 30 degrees. S/F
conducted compressor oil change, investigated electric solenoids, and motor
resistance all reading SAT. S/F conducted OPTEST of NR 1 reefer during OPTEST
52 amps were noted for compressor motor, S/F conducted a through visual
inspection of refrigerant line on return line to NR 3 unit cooler located in
the freeze box. S/F isolated NR 3 unit cooler. S/F believes overheating
compressor caused by system contamination of air and moisture into refrigerant
system.
4.2 SRF Tool Room will issue each gauge, dial indicator, and torque
wrenches when required.
4.3 Ship's Force will issue Handheld Programmer (HHP) tester when
required.
4.4 Removal, installation, and alignment of coupling will be conducted by
JON 38DJA51605-H0l.
4.5 Operational test of the No.1 reefer compressor system will be
conducted by JON 38DJA51605-HO1.
5. GOVERNNT FURNISHED MATERIAL (GFM):
5.1 GOVERNMENT FURNISHED MATERIALS.
Symbol: M: Mndtcrv. ( rnnnzrr-', MT.¯ Mnr1,zI-,-z T.TTM ('1..
_
_
_
_
_
_
_
_
_
MATERIAL LIST
.ii-ITEM PC REF I DESCRIPTION STOCK HAZ
_
_
_
_
_
_
DOC QTY
REQD
_
_
_
_
PARA
NO. NO. NO. NUMBER MAT NO. NO. _ _
. _ _ _ _ _ _
901 BEARING, BALL, ANNULAR, _ _ _ _
9B3110005299144
-
N
_
_
-
2IEA
_
3.2 PIN K55-0077
902 25 2.3 M GASKET, P/N 235A4560AJ2 9B 5330 012227968 N -
1/EA 3.2
-- 3 of 3 --
Source: SAM.gov, as posted. Verify the current solicitation before responding.
Pursue this opportunity with Mindy
See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.
View the original notice on SAM.gov ↗Similar Active Opportunities (NAICS 336611)
Vessel Acquisition Manager (VAM) Services for the Maritime Administration
TRANSPORTATION, DEPARTMENT OF · Sources Sought · due September 1, 2026
J--Aft Boiler Troubleshoot and Repair NOAA Ship Raini
COMMERCE, DEPARTMENT OF · Combined Synopsis/Solicitation · due August 28, 2026
USCGC SPAR Unplanned Dry Dock
HOMELAND SECURITY, DEPARTMENT OF · Solicitation · due September 18, 2026
DRYDOCK: USCGC ROBERT WARD DD FY27
HOMELAND SECURITY, DEPARTMENT OF · Combined Synopsis/Solicitation · due August 26, 2026
Repair REV-1(FO) Motor for No. One Refrigeration Plant Compressor
DEPT OF DEFENSE · Award Notice
IDIQ for Preservation and Non-SUBSAFE Structural Repair Availabilities on United States Naval Submarines Trident Refit Facility (TRF) Bangor, Washington
DEPT OF DEFENSE · Solicitation · due September 4, 2026