What this opportunity is
NASA is seeking to procure a Rockland Piston Cylinder System, which includes a high-pressure pressure vessel, stack components, a temperature controller, and a pressure holding system. This opportunity is set aside for 8(a) small businesses, making it suitable for eligible firms looking to expand their federal contracting portfolio. Interested vendors should note that this is a solicitation notice, indicating the need to prepare a bid in response to the requirements outlined in the statement of work.
Analysis by Mindy, grounded in the SAM.gov notice.
Description
STATEMENT OF WORK
1. Objective/Requirements
NASA Johnson Space Center (JSC) requires the procurement of a Rockland Piston
Cylinder System.
2. Characteristics, Scope, and Specs
LINE PART NO. DESCRIPTION QTY.
1 PV-7 1/2"- 35 kbar pressure vessel
Dimensions: OD approximately 7”, ID 0.5015”,
Thickness 2.000”; Weight 23 lbs
Core: micron grain Carpenter powder metal tool steel;
Shim: hardened and ground tool steel;
Support Rings: forged alloy steel, hardened and
ground;
Safety Ring: ductile stainless steel seamless tubing
machined for proper interference fit;
(2) Machined Bronze Lifting Handles; Thermocouple
mounted on outside diameter – ties in to temperature
controller
2
2 PCSTK Stack components
Bridge: 7” diameter alloy steel;
(1) hardened and ground piston location/endload
insert; Top Plate: 7” alloy steel with tool steel insert;
Thermocouple Spacer: alloy steel, hardened and
ground, slotted: Endload Spacer: alloy steel, hardened
and ground with tapped hole for cable attachment;
(4) quick release coolant fittings for top plate and
bridge; (2) 1/2” tungsten carbide pistons; (1) 1”
tungsten carbide push piece (1) 1/2” tool steel main
ram spacer with dowel pins for location
1
3 SVTC Temperature Controller
Includes the following:
1) Eurotherm EPC3004 Programmable Controller.
2) Control Concepts Phase Angle Firing SCR pack.
3) 12 volt - 5 KVA Transformer.
4) Meter for primary voltage.
5) Illuminated on/off switch.
All components except transformer mounted in an
enameled steel enclosure, approximately 24” H x
20”W x 8”D, with hinged front panel for easy access.
Unit is completely assembled, wired, and tested.
Safety and convenience features include :
1
-- 1 of 3 --
1) Power failure lamp indicates there was an
interruption of power during experimental run and that
the experiment was terminated even though the power
came back on.
2) Fast-Acting semi-conductor fuses prevent damage
to SCR pack.
3) Upper limit alarm shuts off power on temperature
over-run; run is terminated (latching relay prevents
controller from switching power back on as
temperature drops).
4) Panel mounted light indicates whether temperature
fluctuation, e.g. ± 5 degrees C, has occurred at any
time during experimental run.
4 PHS Data Pressure holding system, with data
The PHS consists of a small volume high pressure
syringe pump, driven by a 90V DC motor
with gear reduction, driving a second, right-angle gear
reducer. All mechanical and hydraulic components are
mounted on an aluminum channel 8" wide x 44" long;
this may be wall-mounted or placed on the floor
behind the press. Mounting feet are provided.
The PHS is intended to keep your piston cylinder main
ram pressure constant after it is increased via manual
control. The pump maintains constant pressure during
room temperature variations in the lab, and it also
holds pressure during quenching at the end of your
experiment.
The electrical controls are built into the temperature
control panel; data acquisition software with Enet
connection is included in the panel as well.
1
5 150T 150 ton hydraulic press with Shields and Base:
Type: 4-post single-acting down-moving; solid steel
construction
Capacity: 150 tons
Endload cylinder: 150 ton single-acting with return
spring and chrome plated piston
Main Ram: 100 ton single acting, with return spring
and chrome plated piston, with
Nickel plated steel mounting plate;
Column diameter: approximately 3”, alloy steel
Weight: approximately 1400 lbs with stack and safety
shields Height: 56”; Width: 24”; Depth: 24”; Base 24”
x 24”
“Daylight” between frame top and bottom plates: 23”;
between posts: 10-1/4” between hydraulic cylinders:
12-1/2”
1
-- 2 of 3 --
Welded steel gauge panel with (2) Stewarts 10 KSI
gauges, 4” diameter
(2) Autoclave stainless steel shutoff valves; high
pressure stainless steel tubing and fittings as required.
6 RR10T 10 ton hydraulic press 1
7 ENPKG Enerpac pump w/accessories
Enerpac 10,000 PSI electric/hydraulic pump with two
way valve.
Jog switch mounted on 10’ cord.
(2) 6’ hoses, 4” diameter/10 KSI gauge,
additional shut off valve.
Valves, hoses and fittings as required to accommodate
150T press and 10T press
1