Xenon Gas Purchase

NATIONAL AERONAUTICS AND SPACE ADMINISTRATION

Notice type
Combined Synopsis/Solicitation
Solicitation #
80NSSC26933373Q
NAICS
325120
PSC
6850
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
June 24, 2026
Response due
June 30, 2026
Place of performance
Cleveland, OH

What this opportunity is

The National Aeronautics and Space Administration (NASA) is soliciting a Total Small Business Set-Aside for the purchase of high-purity xenon gas for electric propulsion testing at the NASA Glenn Research Center in Ohio. The procurement includes associated costs such as shipping and bottle cylinder costs, with the vendor required to provide pricing for three specified xenon quantities: 10,000 L, 15,000 L, and 20,000 L. The notice type is a Combined Synopsis/Solicitation, which means interested small businesses should track the solicitation for updates rather than preparing a bid.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

NASA Glenn Research Center June 12, 2026 Specifications: The vendor will provide high-purity xenon to NASA for use in electric propulsion testing. The procurement should include all associated costs, including shipping as well as the bottle cylinder cost. The Contractor shall provide the Government with total pricing for each of the following xenon quantities for evaluation purposes: i. 10,000 L ii. 15,000 L iii. 20,0000 L NASA requires Xe with a purity greater than or equal to 99.999% and meets the requirements for impurities listed in Table 1 measuring the impurities in each individual bottle. Each cylinder shall be fit with a rare gas valve or a bellows-sealed valve to eliminate stem leakage. The external connection shall be a CGA 580 valve fitting. Each cylinder shall be labelled with its tare weight and have a minimum of one (1) year remaining on its DOT certification. Table 1 Maximum Allowable Impurities Constituent Allowable Content, measured Oxygen (O2) ≤ 0.1 ppm Water (H2O) ≤ 0.1 ppm Carbon Monoxide (CO) ≤ 0.5 ppm Carbon Dioxide (CO2) ≤ 0.5 ppm Carbon Tetrafluoride (CF4) ≤ 0.1 ppm Total hydrocarbons (THC) ≤ 0.1 ppm Nitrogen (N2) ≤ 1.0 ppm Hydrogen (H2) ≤ 2.0 ppm Krypton (Kr) ≤ 5.0 ppm Argon (Ar) ≤ 1.0 ppm Total Impurities ≤ 10.4 ppm (balance xenon) A certificate of analysis is required for each cylinder to verify purity requirements. Lot impurities or measured impurities prior to any xenon transfer are not valid. Each bottle delivered to the Government shall have a Certificate of Analysis including: • the quantity of xenon in liters at standard temperature and pressure (after extraction of sample as required for cylinder analysis), • the actual measured impurity values for that cylinder, • the measurement uncertainty for each impurity, and A liter will be defined at standard temperature and pressure conditions of 32 degrees Fahrenheit and 29.92 inches of mercury. Any bottle that fails to comply with the requirements for measured impurity or does not have an accompanying certificate of measured impurity levels for that bottle shall be rejected by the government. -- 1 of 1 --

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Similar Active Opportunities (NAICS 325120)