Z1DA--542-21-113 | Correct FCA Deficiencies – Repair Water Penetration | NCO 4 Construction East (VA-26-00020634) (VA-26-00020634)
VETERANS AFFAIRS, DEPARTMENT OF
Notice type
Solicitation
Solicitation #
36C24426B0003
NAICS
238190
PSC
Z1DA
Posted
July 22, 2026
Response due
September 2, 2026
Description
PROJECT SPECIFICATIONS
Department of Veterans Affairs
Coatesville VAMC
Correct FCA Deficiencies – Repair Water Penetration
VA Project No. 542-21-113
100% For Bid
August 28, 2024
Prepared by:
Apogee Consulting Group, PA
1151 Kildaire Farm Road
Cary, NC 27511
-- 1 of 470 --
-- 2 of 470 --
Coatesville VA Medical Center
Correct FCA Deficiencies – Repair Water Penetration
Project: 542-21-113
1151 Kildaire Farm Road
Cary, NC 27511
acg-pa.com
Date: August 28, 2024
Jason Gerhart, PE
Civil Engineer
-- 3 of 470 --
-- 4 of 470 --
Coatesville VA Medical Center
Correct FCA Deficiencies – Repair Water Penetration
Project: 542-21-113
1151 Kildaire Farm Road
Cary, NC 27511
acg-pa.com
Date: August 28, 2024
Jeffrey A. Brooks, AIA
Registered Architect
Docusign Envelope ID: 00CEC6B5-8701-4EB6-ADD7-7AFB3DE235F9
-- 5 of 470 --
-- 6 of 470 --
Coatesville VAMC August 28, 2024
Correct FCA Deficiencies – Repair Water Penetration 100% For Bid
Coatesville, PA VA #542-21-113
00 01 10 - 1
DEPARTMENT OF VETERANS AFFAIRS
VHA MASTER SPECIFICATIONS
TABLE OF CONTENTS
Section 00 01 10
SECTION NO. DIVISION AND SECTION TITLES DATE
DIVISION 00 - SPECIAL SECTIONS
00 01 15 List of Drawing Sheets 05-20
DIVISION 01 - GENERAL REQUIREMENTS
01 00 00 General Requirements 11-21
01 32 16.15 Project Schedules (Small Projects – Design/Bid/Build 11-21
01 33 23 Shop Drawings, Product Data, and Samples 09-22
01 35 26 Safety Requirements 10-22
01 42 19 Reference Standards 11-20
01 45 00 Quality Control 02-21
01 45 29 Testing Laboratory Services 11-18
01 57 19 Temporary Environmental Controls 01-21
01 74 19 Construction Waste Management 04-22
DIVISION 02 – EXISTING CONDITIONS
02 41 00 Demolition 11-22
02 82 13.21 Asbestos Roofing Abatement 01-21
02 83 33.13 Lead-Based Paint Removal and Disposal 01-21
DIVISION 03 – CONCRETE
03 30 53 (Short-Form) Cast-in-Place Concrete 01-21
DIVISION 04 – MASONRY
04 01 00 Maintenance of Masonry 01-21
04 05 13 Masonry Mortaring 10-17
04 05 16 Masonry Grouting 01-21
04 20 00 Unit Masonry 08-17
DIVISION 06 – WOOD, PLASTICS AND COMPOSITES
06 10 00 Rough Carpentry 10-17
06 20 00 Finish Carpentry 01-21
DIVISION 07 - THERMAL AND MOISTURE PROTECTION
07 01 50.19 Preparation for Re-Roofing 01-21
07 13 52 Modified Bituminous Sheet Waterproofing 01-21
07 22 00 Roof and Deck Insulation 01-21
07 31 13 Asphalt Shingles 02-21
-- 7 of 470 --
Coatesville VAMC August 28, 2024
Correct FCA Deficiencies – Repair Water Penetration 100% For Bid
Coatesville, PA VA #542-21-113
00 01 10 - 2
SECTION NO. DIVISION AND SECTION TITLES DATE
07 53 23 Ethylene-Propylene-Diene-Monomer Roofing 01-21
07 56 00 Fluid-Applied Roofing 01-21
07 56 00.1 BOD-Sika 641 Gutter Coating
07 60 00 Flashing and Sheet Metal 01-21
07 71 00 Roof Specialties 01-21
07 92 00 Joint Sealants 04-22
DIVISION 09 - FINISHES
09 91 00 Painting 01-21
DIVISION 31 – EARTHWORK
31 20 00 Earthwork 10-12
31 23 19 Dewatering 10-12
DIVISION 32 – EXTERIOR IMPROVEMENTS
32 05 23 Cement and Concrete for Exterior Improvements 08-16
32 12 16 Asphalt Paving 09-15
32 17 23 Pavement Markings 08-16
32 31 13 Chain Link Fences and Gates 06-18
32 90 00 Planting 08-16
DIVISION 33 – UTILITIES
33 40 00 Storm Sewer Utilities 12-17
---END---
-- 8 of 470 --
Coatesville VAMC August 28, 2024
Correct FCA Deficiencies – Repair Water Penetration 100% For Bid
Coatesville, PA VA #542-21-113
00 01 15 - 1
SECTION 00 01 15
LIST OF DRAWING SHEETS
The drawings listed below accompanying this specification form a part of
the contract.
Drawing No. Title
GENERAL
G-001 COVER
G-002 GENERAL INFORMATION, ARCHITECTURAL SYMBOLS,
ABBREVIATIONS AND NOTES
CIVIL
GI-001 NOTES, LEGEND, AND DETAILS
XP-101 SURVEY OVAL 1
XP-102 SURVEY OVAL 2
XP-103 SURVEY OVAL 1 - UTILITIES
XP-104 SURVEY OVAL 2 - UTILITIES
CD-100 OVERALL SITE DEVELOPMENT PLAN
GC-100 EROSION & SEDIMENT CONTROL NARRATIVE
GC-101 EROSION & SEDIMENT CONTROL BUILDING 2 - PRIORITY 1
GC-102 EROSION & SEDIMENT CONTROL BUILDING 4 - PRIORITY 1
GC-103 EROSION & SEDIMENT CONTROL BUILDING 6 - PRIORITY 1
GC-104 EROSION & SEDIMENT CONTROL BUILDING 7 - PRIORITY 1
GC-105 EROSION & SEDIMENT CONTROL BUILDING 1 - PRIORITY 2
GC-106 EROSION & SEDIMENT CONTROL BUILDING 8 - PRIORITY 2
GC-107 EROSION & SEDIMENT CONTROL BUILDING 59 - PRIORITY 2
GC-108 EROSION & SEDIMENT CONTROL BUILDING 39 - PRIORITY 3
GC-501 EROSION & SEDIMENT CONTROL NOTES & DETAILS
CD-101 DEMOLITION PLAN BUILDING 2 - PRIORITY 1
CD-102 DEMOLITION PLAN BUILDING 4 - PRIORITY 1
CD-103 DEMOLITION PLAN BUILDING 6 - PRIORITY 1
CD-104 DEMOLITION PLAN BUILDING 7 - PRIORITY 1
CD-105 DEMOLITION PLAN BUILDING 1 - PRIORITY 2
CD-106 DEMOLITION PLAN BUILDING 8 - PRIORITY 2
CD-107 DEMOLITION PLAN BUILDING 59 - PRIORITY 2
CD-108 DEMOLITION PLAN BUILDING 39 - PRIORITY 3
CS-101 STORM IMPROVEMENT PLAN BUILDING 2 - PRIORITY 1
-- 9 of 470 --
Coatesville VAMC August 28, 2024
Correct FCA Deficiencies – Repair Water Penetration 100% For Bid
Coatesville, PA VA #542-21-113
00 01 15 - 2
CS-102 STORM IMPROVEMENT PLAN BUILDING 4 - PRIORITY 1
CS-103 STORM IMPROVEMENT PLAN BUILDING 6 - PRIORITY 1
CS-104 STORM IMPROVEMENT PLAN BUILDING 7 - PRIORITY 1
CS-105 STORM IMPROVEMENT PLAN BUILDING 1 - PRIORITY 2
CS-106 STORM IMPROVEMENT PLAN BUILDING 8 - PRIORITY 2
CS-107 STORM IMPROVEMENT PLAN BUILDING 59 - PRIORITY 2
CS-108 STORM IMPROVEMENT PLAN BUILDING 39 - PRIORITY 3
CG-101 GRADING PLAN BUILDING 2 - PRIORITY 1
CG-102 GRADING PLAN BUILDING 4 - PRIORITY 1
CG-103 GRADING PLAN BUILDING 6 - PRIORITY 1
CG-104 GRADING PLAN BUILDING 7 - PRIORITY 1
CG-105 GRADING PLAN BUILDING 1 - PRIORITY 2
CG-106 GRADING PLAN BUILDING 8 - PRIORITY 2
CG-107 GRADING PLAN BUILDING 59 - PRIORITY 2
CG-108 GRADING PLAN BUILDING 39 - PRIORITY 3
CU-261 STORM SEWER PROFILES
CU-262 STORM SEWER PROFILES
CU-263 STORM SEWER PROFILES
CU-264 STORM SEWER PROFILES
CU-265 STORM SEWER PROFILES
CU-266 STORM SEWER COMPUTATIONS
LS-101 LANDSCAPE PLAN BUILDING 4 - PRIORITY 1
LS-102 LANDSCAPE PLAN BUILDING 1 - PRIORITY 2
LS-103 LA…
Source: SAM.gov, as posted. Verify the current solicitation before responding.
Pursue this opportunity with Mindy
See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.
View the original notice on SAM.gov ↗Similar Active Opportunities (NAICS 238190)
USCGC Maple Fantail awning fabrication and installation
HOMELAND SECURITY, DEPARTMENT OF · Combined Synopsis/Solicitation · due July 29, 2026
Monument Sign - Natick Soldiers Systems Center
DEPT OF DEFENSE · Combined Synopsis/Solicitation · due August 7, 2026
Z--Replacement of Kettles 7A & 7B
INTERIOR, DEPARTMENT OF THE · Combined Synopsis/Solicitation · due July 28, 2026
Z--Grand Coulee Washington Power Plant Turbine Repair
INTERIOR, DEPARTMENT OF THE · Solicitation · due August 5, 2026
Z--Replacement of Kettles 7A & 7B
INTERIOR, DEPARTMENT OF THE · Combined Synopsis/Solicitation · due July 28, 2026
Z--Hungry Horse Power Plant Turbine Runner Cavitation
INTERIOR, DEPARTMENT OF THE · Solicitation · due August 4, 2026