What this opportunity is
The Department of Veterans Affairs is soliciting bids for the replacement of the flat roof on Building 57 at the Coatesville VAMC in Coatesville, PA. This construction project falls under NAICS code 236220, which pertains to commercial and institutional building construction. The solicitation is open to all businesses, and the notice type indicates that bidders should track the solicitation for updates. The project involves various aspects of construction, including demolition, concrete work, roofing, insulation, and electrical installations, as outlined in the VHA Master Specifications.
Analysis by Mindy, grounded in the SAM.gov notice.
Description
Replace Flat Roof Building 57
Bid Documents
Coatesville VAMC | Coatesville, PA
03-01-2026
00 01 10-1
DEPARTMENT OF VETERANS AFFAIRS
VHA MASTER SPECIFICATIONS
TABLE OF CONTENTS
Section 00 01 10
SECTION NO DIVISION AND SECTION TITLES DATE
DIVISION 01 - GENERAL REQUIREMENTS
01 32 16.15 Project Schedules (Small Projects – Design/Bid/Build 12-2025
01 33 23 Shop Drawings, Product Data, and Samples 03-2026
01 35 26 Safety Requirements for Major Projects 05-2024
01 45 00 Quality Control 02-2021
01 45 29 Testing Laboratory Services 11-2018
01 57 19 Temporary Environmental Controls 01-2021
01 74 19 Construction Waste Management 04-2022
01 81 13 Sustainable Construction Requirements 10-2017
DIVISION 02 – EXISTING CONDITIONS
02 41 00 Demolition 08-2017
DIVISION 03 – CONCRETE
03 30 53 (Short-Form) Cast-in-Place Concrete 01-2021
03 51 16 Gypsum Concrete Roof Decks 01-2021
DIVISION 06 – WOOD, PLASTICS AND COMPOSITES
06 10 00 Rough Carpentry 10-2017
DIVISION 07 - THERMAL AND MOISTURE PROTECTION
07 01 50.19 Preparation for Re-Roofing 01-2021
07 22 00 Roof and Deck Insulation 01-2021
07 53 23 Ethylene-Propylene-Diene-Monomer Roofing 01-2021
07 60 00 Flashing and Sheet Metal 01-2021
07 72 00 Roof Accessories 01-2021
07 84 00 Firestopping 01-2021
07 92 00 Joint Sealants 04-2022
DIVISION 09 – FINISHES
09 06 00 Schedule for Finishes 01-2021
DIVISION 22 – PLUMBING
22 05 11 Common Work Results for Plumbing 01-2023
22 14 00 Facility Storm Drainage 09-2015
-- 1 of 452 --
Replace Flat Roof Building 57
Bid Documents
Coatesville VAMC | Coatesville, PA
03-01-2026
00 01 10-2
SECTION NO DIVISION AND SECTION TITLES DATE
DIVISION 23 – HEATING, VENTILATING, AND AIR
CONDITIONING (HVAC)
23 05 11 Common Work Results for HVAC 03-2023
23 05 12 General Motor Requirements for HVAC and Steam
Generation Equipment
03-2023
23 05 41 Noise and Vibration Control for HVAC Piping and
Equipment
03-2023
23 05 93 Testing, Adjusting, and Balancing for HVAC 03-2023
23 31 00 HVAC Ducts and Casings 03-2023
23 34 00 HVAC Fans 03-2023
23 37 00 Air Outlets and Inlets 03-2023
DIVISION 26 – ELECTRICAL
26 05 11 Requirements for Electrical Installations 11-2022
26 05 19 Low-Voltage Electrical Power Conductors and Cables 11-2022
26 05 26 Grounding and Bonding for Electrical Systems 11-2022
26 29 11 Motor Controllers 11-2022
26 41 00 Facility Lightning Protection 11-2022
-- 2 of 452 --
Replace Flat Roof Building 57
Bid Documents
Coatesville VAMC | Coatesville, PA
11-01-21
01 00 00 -1
SECTION 01 00 00
GENERAL REQUIREMENTS
GENERAL
1.1 SAFETY REQUIREMENTS
A. Refer to section 01 35 26, SAFETY REQUIREMENTS for safety
and infection control requirements.
1.2 GENERAL INTENTION
A. Contractor shall completely prepare site for building
operations, including demolition and removal of existing
structures, and furnish labor and materials and perform
work for Replace Flat Roof Building 1 as required by
drawings and specifications.
B. Visits to the site by Bidders may be made only by
appointment with the Contracting Officer.
C. Before placement and installation of work subject to tests
by testing laboratory retained by Department of Veterans
Affairs, the Contractor shall notify the COR in sufficient
time to enable testing laboratory personnel to be present
at the site in time for proper taking and testing of
specimens and field inspection. Such prior notice shall be
not less than three workdays unless otherwise designated by
the COR.
D. All employees of general contractor and subcontractors
shall comply with VA security management program and obtain
permission of the VA police, be identified by project and
employer, and restricted from unauthorized access.
1.3 STATEMENT OF BID ITEM(S)
A. ITEM I, GENERAL CONSTRUCTION: Work includes general
construction, alterations, drainage, and necessary removal
-- 3 of 452 --
Replace Flat Roof Building 57
Bid Documents
Coatesville VAMC | Coatesville, PA
11-01-21
01 00 00 -2
of existing structures and construction and certain other
items.
1.4 SPECIFICATIONS AND DRAWINGS FOR CONTRACTOR
A. Drawings and contract documents may be obtained from the
website where the solicitation is posted. Additional copies
will be at Contractor's expense.
1.5 CONSTRUCTION SECURITY REQUIREMENTS
A. Security Plan:
1. The security plan defines both physical and
administrative security procedures that will remain
effective for the entire duration of the project.
2. The General Contractor is responsible for assuring that
all sub-contractors working on the project and their
employees also comply with these regulations.
B. Security Procedures:
1. General Contractor’s employees shall not enter the
project site without appropriate badge. They may also be
subject to inspection of their personal effects when
entering or leaving the project site.
2. Before starting work the General Contractor shall give
one week’s notice to the Contracting Officer so that
security can be provided for the employees. This notice
is separate from any notices required for utility
shutdown described later in this section.
3. No photography of VA premises is allowed without written
permission of the Contracting Officer. Patients and staff
are not to be photographed at any time.
4. VA reserves the right to close down or shut down the
project site and order General Contractor’s employees off
the premises in the event of a national emergency. The
-- 4 of 452 --
Replace Flat Roof Building 57
Bid Documents
Coatesville VAMC | Coatesville, PA
11-01-21
01 00 00 -3
General Contractor may return to the site only with the
written approval of the Contracting Officer.
C. Key Control:
1. The General Contractor shall provide duplicate keys and
lock combinations to the Contracting officers
representative (COR) for the purpose of security
inspections of every area of project including toolboxes
and parked machines and take any emergency action.
D. Document Control:
1. Before starting any work, the General Contractor/Sub
Con…
Source: SAM.gov, as posted. Verify the current solicitation before responding.
Pursue this opportunity with Mindy
See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.