What this opportunity is
The Department of Energy is seeking Industrial Hygiene Sampling and Analysis Services for the Princeton Plasma Physics Laboratory in New Jersey. This opportunity is open to all businesses, as there is no set-aside for small businesses. The contract requires the provision of sampling media, laboratory analysis, and technical support, with a focus on compliance with OSHA and other relevant standards. As this is a Sources Sought notice, interested vendors should track the opportunity for potential future solicitations rather than submit bids at this stage.
Analysis by Mindy, grounded in the SAM.gov notice.
Description
STATEMENT OF WORK
Industrial Hygiene Sampling and Analysis Services
CAT; EXEMPT, QAPD APP B #4
UNIQUE PROJECT IDENTIFIER:
(Not Applicable)
REVISION: 0
April 20, 2026
WRITTEN BY:
Neil Gerrish
Head, Occupational Safety and Health Division
REVIEWED BY:
Julia McLaughlin
Senior Industrial Hygienist
REVIEWED BY:
Joy Fleming
Head, Construction Project Safety Division
APPROVED BY:
Jonathon LaCarrubba
Chief Safety Officer & Deputy Director, Environment, Safety and Health
PRINCETON PLASMA PHYSICS LABORATORY
P.O. BOX 451
PRINCETON, N.J. 08543
609-243-2000
-- 1 of 6 --
RECORD OF CHANGES
Revision Description Affected Section(s) Date
0 Initial Issue
-- 2 of 6 --
1.0 Introduction
The US Department of Energy (DOE) Princeton Plasma Physics Laboratory (PPPL) requires a subcontract
agreement for Industrial Hygiene (IH) Sampling and Analysis Services. Under this agreement, the
subcontractor shall provide all necessary laboratory analysis, sampling media, and technical support as
ordered by authorized PPPL personnel. This contract shall provide for the timely delivery of sampling
media and the rapid turnaround of analytical results in response to orders placed by PPPL.
2.0 Scope
Industrial hygiene sampling and analysis services must meet the requirements, codes, and standards
referenced in Section 3.0. This scope includes the provision of media (filters, sorbent tubes, badges,
etc.), the analysis of samples for chemical and physical hazards, and the reporting of data. PPPL
makes no representation as to the anticipated volume of analytical services requested under this
contract.
3.0 Applicable Documents and Standards
The following documents govern the work contained within this Statement of Work and are the latest
revision available:
● Occupational Safety and Health Administration (OSHA), 29 CFR 1910 Subpart Z.
● NIOSH Manual of Analytical Methods (NMAM).
● OSHA Sampling and Analytical Methods and protocols.
● ISO/IEC 17025 General requirements for the competence of testing and calibration laboratories.
● American Industrial Hygiene Association (AIHA) Laboratory Accreditation Programs (LAP, LLC).
4.0 Responsibilities
4.1 PPPL
The PPPL Technical Representative (PTR) is responsible for oversight of the vendor’s performance,
ensuring compliance with SOW requirements, and assessing the quality of analytical services. The PTR or
designee shall coordinate the shipment of samples and the selection of analytical methods.
4.2 Subcontractor
4.2.1 The vendor will abide by all PPPL policies and maintain AIHA-LAP accreditation for
all requested analytes.
4.2.2 The vendor will provide high-quality sampling media and standardized collection
instructions.
4.2.3 The vendor will provide technical consultation regarding limit of detection (LOD),
level of quantification (LOQ), and potential interferences for specific sampling requests.
4.2.4 Submission of invoices to PPPL Accounts Payable in a timely manner.
5.0 Requirements
5.1 Vendor will acknowledge receipt of samples within 24 hours of arrival at the laboratory.
5.1.1 In the event that a specific analytical method is discontinued, the Vendor will notify the
PPPL PTR and suggest suitable alternatives.
-- 3 of 6 --
5.2 Media and Deliveries
5.2.1 Sampling media (e.g., cassettes, tubes) shall be delivered to PPPL within five (5) business
days (standard delivery) of request unless otherwise requested sooner.
5.2.2 Media provided must have a shelf life of at least six months unless otherwise specified for
specific chemical agents.
5.3 Laboratory Standards
5.3.1 All analysis must be performed by a laboratory accredited by the AIHA Laboratory
Accreditation Programs (LAP) for the specific scope of testing.
5.3.2 Samples must be analyzed within the holding times specified by the applicable analytical
method. The vendor will notify PPPL contact if holding times may be exceeded.
5.3.3 The vendor will notify the PPPL contact as soon as possible if sample loss, damage,
contamination, or analytical equipment failure affects the ability to analyze a submitted sample.
6.0 Subcontractor Qualifications
The laboratory must be AIHA accredited. The laboratory director or lead chemist should possess
advanced degrees in chemistry or related sciences and/or hold a relevant professional certification
(e.g., CIH).
7.0 7.0 Environmental, Safety & Health
The subcontractor shall handle all samples in accordance with OSHA’s Laboratory Standard (29 CFR
1910.1450) and ensure the safe disposal of hazardous waste generated during the analytical process.
8.0 Quality Assurance Requirements
The vendor is responsible for performing and complying with all requirements set forth in this Statement of
Work. PPPL shall assess the quality of services as they are performed by the vendor. PPPL shall address any
deficiencies with the vendor.
9.0 Shipping, Storage and Handling
9.1 Shipments of media to PPPL shall be packaged to prevent damage or contamination.
9.2 Vendor shall provide Chain of Custody (COC) forms with all media shipments.
9.3 PPPL personnel will complete the COC documentation at the time of sample collection. The vendor
shall maintain custody records through analysis and reporting.
9.4 Vendor will replace, at no cost to PPPL, any media that arrives damaged or contaminated.
-- 4 of 6 --
10.0 Warranty
Notwithstanding inspection and acceptance by PPPL or any provisions concerning the conclusiveness thereof,
the subcontractor shall guarantee and warrant that all items furnished shall meet the requirements specified
in this SOW.
11.0 Documentation and Deliverables
The Vendor shall provide analytical reports for all transactions that include:
● BPA or Purchase Order Number.
● PPPL Sample ID and Laboratory Lab ID.
● Date Sampled, Date Received, and Date Analyzed.
● Analytical Method used and Limit of Quantitation (LOQ).
● Final results reported in appropriate units (e.g., ppm, mg/m³, or μg) as applicable to the analyte
method.
Final reports will be delivered within five (5) to ten (10…