J065 - UPS Battery Replacements and Service

VETERANS AFFAIRS, DEPARTMENT OF

Notice type
Combined Synopsis/Solicitation
Solicitation #
36C25926Q0862
NAICS
811210
PSC
J065
Set-aside
Small Business Set Aside - Total
Posted
September 18, 2026
Response due
September 22, 2026
Place of performance
Waco, TX

What this opportunity is

The Department of Veterans Affairs is seeking a contractor for Uninterruptible Power Supply (UPS) battery replacements and maintenance services at the Waco Call Center in Texas. This opportunity is set aside for small businesses and includes a one-time replacement of 160 batteries, along with ongoing preventive maintenance and emergency repair services for four UPS units over a base year and four option years. Interested vendors should note that this is a Combined Synopsis/Solicitation, indicating that they will need to track the opportunity closely for bidding details.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

B.2 STATEMENT OF WORK (SOW) Uninterruptible Power Supply/Module (UPS/UPM) Battery Replacement and Maintenance Support Services for the Veterans Health Administration - Member Services (VHA-MS) Waco Call Center Introduction/Background VHA Member Services operates UPS/UPM systems at the Waco Call Center that provide backup emergency power to the facility's communication servers (connected to the VA nationwide network), desktops/workstations, computer systems, and critical infrastructure. This requirement establishes (a) a one-time removal, disposal, and replacement of 160 backup batteries, and (b) recurring preventive maintenance and service agreement support for 4 UPS/UPM units and their associated battery cabinets and remote panel monitors, under a base year and four option years contract. Locations/Places of Performance: Site Address Waco Call Center, Bldg. 90 4800 Memorial Drive, Bldg. 90, Waco, TX 76711 Objective Continuous, reliable UPS/UPM operation is essential to this organization's mission. This requirement establishes a one-time battery replacement effort plus recurring preventive maintenance, service agreement support, and emergency repair services to avoid catastrophic UPS/UPM and battery failure, across a base year plus four option years. Period of Performance Period Start End Base Year 9/11/2026 9/10/2027 Option Year 1 9/11/2027 9/10/2028 Option Year 2 9/11/2028 9/10/2029 Option Year 3 9/11/2029 9/10/2030 Option Year 4 9/11/2030 9/10/2031 Within thirty (30) calendar days after contract award, the Contractor shall complete removal, disposal, and installation of all 160 replacement batteries per Section 7.9. Within sixty (60) calendar days after contract award, all 4 UPS/UPMs shall be entered into the preventive maintenance and service agreement plan per Section 7. Scope Summary Service Category Frequency Priced As Battery Removal, Disposal, and Replacement (160 ea.) (see Section 7.9) One-time, Base Year only Fixed price UPS/UPM Preventive Maintenance (see Sections 7.1-7.4, 7.7) Semi-annual Fixed price, each period of performance Battery Cabinet PM (see Section 7.5) Semi-annual Fixed price, each period of performance Battery Quarterly Checks (see Section 7.6) Quarterly Fixed price, each period of performance Corrective/Unscheduled Repairs (see Section 8) As needed Quoted, priced per repair (parts + labor) Emergency Repair Service (see Section 9) As needed, 24/7 Quoted, priced per repair (parts + labor) 5. Equipment List Site-Level Summary System Waco Bldg. 90 Total UPS/UPM Units 4 4 Battery Cabinets 4 4 Remote Panel Monitors 4 4 Total Batteries (currently installed) 160 160 5.1 Waco Bldg. 90 Table 1- UPS/UPM Units: UPS# Make Model Serial# 1 Eaton 93PM-150-3 EN182UXX0S 2 Eaton 9390-120 ED515CAB07 3 Mitsubishi UP9933A-A803DU-4 08- 7M72582-04 4 Eaton 93PM-150-3 EN173UXX0S Table 2 - Battery Cabinets: Cabinet# Assoc.UPS# Make Model 1 1 Eaton PWHR12390W 4FR 2 2 Eaton PWHR12390W4FR 3 3 Eaton PWHR12390W4FR 4 4 Eaton PWHR12390W4FR Table 3 - Batteries (individual cells/units within each cabinet) Assoc. Cabinet # Make Model Capacity QTY 1-4 (combined) Eaton PWHR12390W4FR 390W 160 Contractor Qualifications and Personnel Requirements Company Experience. The prime Contractor shall have a minimum of three (3) years of verifiable experience performing maintenance, repair, and battery replacement services on large commercial UPS systems of comparable size and complexity (100 kVA or greater). Experience shall be documented via past performance references in the proposal. Demonstrated Technical Capability. The Contractor shall demonstrate the capability to service Eaton and Mitsubishi UPS/UPM systems of the type identified in Section 5, through the following, submitted with the proposal: Eaton-authorized service provider status; OEM-issued training certification; Equivalent third-party technical certification for the applicable models. Additionally, the Contractor shall be an authorized dealer of the proposed replacement batteries and any other equipment or components furnished under this contract, and shall submit documentation (e.g., an authorized dealer letter or distributor agreement from the manufacturer) evidencing this status with its proposal. Buy American Statute Compliance. All replacement batteries, parts, and end products furnished under this contract shall comply with the Buy American Statute (41 U.S.C. chapter 83) and its implementing regulations at FAR Part 25, unless an exception applies (e.g., commercially available off-the-shelf (COTS) item exception, non-availability, unreasonable cost, or public interest determination). The Contractor shall certify the country of origin and domestic content of all end products and construction materials proposed and, upon request, provide documentation sufficient for the Contracting Officer to verify compliance. Any request for exception to the Buy American Statute shall be submitted with the Contractor's proposal, identifying the applicable exception and supporting rationale. Technician Qualifications. All technicians performing work under this contract shall: Hold a valid journeyman electrician license or equivalent credential recognized in the State of Texas (including Texas Department of Licensing and Regulation (TDLR) electrical contractor licensing where applicable), or demonstrate equivalent documented UPS technical training from an OEM or accredited training program; Possess a minimum of three (3) years of hands-on UPS maintenance and battery replacement experience; Hold a current OSHA 10-Hour General Industry Safety and Health certification (all on-site technicians, not supervisors only); Pass a background check as required for access to the VA facility per VA security protocols. Supervisor Requirement. A qualif

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Similar Active Opportunities (NAICS 811210)