Pike Underground Utility Upgrade

AGRICULTURE, DEPARTMENT OF

Notice type
Combined Synopsis/Solicitation
Solicitation #
1240LT26Q0090
NAICS
237110
PSC
Y1NZ
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
June 1, 2026
Response due
July 13, 2026
Place of performance
CO

What this opportunity is

The Department of Agriculture is seeking a contractor for the Pike Underground Utility Upgrade project, which involves the replacement of sewer lines, waterlines, and septic systems in the Pike-San Isabel National Forest and surrounding areas in Colorado. This opportunity is set aside for total small businesses under FAR 19.5, making it suitable for small contractors with relevant experience in utility upgrades and construction. The notice type is a Combined Synopsis/Solicitation, indicating that interested businesses should track the opportunity closely for bidding details and requirements.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

UNITED STATES DEPARTMENT OF AGRICULTURE FOREST SERVICE REGION 2 PIKE - SAN ISABEL NATIONAL FORESTS & CIMARRON AND COMANCHE NATIONAL GRASSLANDS PIKES PEAK, SOUTH PARK, & SOUTH PLATTE RANGER DISTRICTS Pike Underground Utilities Upgrade Project Manual May 1, 2026 -- 1 of 136 -- PIKE UNDERGROUND UTILITIES UPGRADE PIKE-SAN ISABEL NATIONAL FOREST & CIMARRON AND COMANCHE NATIONAL GRASSLANDS 001500 - 1 LIST OF DRAWINGS & SPECIFICATIONS SECTION 001500 PIKE UNDERGROUND UTILITES UPGRADE LIST OF DRAWINGS AND SPECIFICATIONS PART 1 – GENERAL 1.1 DESCRIPTION A. List of Contract Drawings: 1. Index of Sheets: T1.1 Title Sheet T1.2 General Notes C1.1 Lake George Site Plan: Replacement Sewer Lines C1.2 Section Detail: LG Office Sewer Lines C1.3 Section Detail: LG Sepic System C2.1 MFC Site Plan: Replacement Sewer Lines C2.2 MFC Site Plan: Replacement Hydrants C2.3 Section Detail: MFC Classroom Sewer Lines C3.1 Fairplay WC Site Plan: Replacement Waterline C4.1 AG Ranch WC Site Plan: Septic Tank Replacement D1.1 Details: Lake George Septic D1.2 Details: Lake Geroge Septic 2 D1.3 Details: Hydrant and Trench D1.4 Details: AG Ranch Septic Tanks 14 Total Plan Sheets in this Contract B. List of Contract Specifications 1. Index of Specifications DIVISION 1 - GENERAL REQUIREMENTS Section 001500 List of Drawings and Specifications Section 010150 General Requirements Section 010250 Definition of Items and Measurement and Payment Section 011500 Hazardous Materials Requirements Section 014000 Quality Requirements DIVISION 2 – EXISTING CONDITIONS Section 024119 Selective Demolition DIVISION 22 - PLUMBING Section 221316 Sanitary Waste Piping DIVISION 26 - ELECTRICAL Section 260500 Electrical Materials and Methods -- 2 of 136 -- PIKE UNDERGROUND UTILITIES UPGRADE PIKE-SAN ISABEL NATIONAL FOREST & CIMARRON AND COMANCHE NATIONAL GRASSLANDS 001500 - 2 LIST OF DRAWINGS & SPECIFICATIONS DIVISION 31 - EARTHWORK Section 311100 Clearing and Grubbing Section 312250 Earthwork Section 312317 Trenching, Bedding, and Backfill for Utilities Section 312500 Temporary Erosion and Sedimentation Control DIVISION 32 – EXTERIOR IMPROVEMENTS Section 321313 Concrete for Minor Structures Section 329219 Seeding DIVISION 33 - UTILITIES Section 331116 Water Distribution Section 331219 Water Hydrants Section 333110 Sanitary Sewerage END OF SECTION 001500 -- 3 of 136 -- PIKE UNDERGROUND UTILITIES UPGRADE PIKE-SAN ISABEL NATIONAL FOREST & CIMARRON AND COMANCHE NATIONAL GRASSLANDS 001500 - 3 LIST OF DRAWINGS & SPECIFICATIONS This page intentionally left blank. -- 4 of 136 -- PIKE UNDERGROUND UTILITIES UPGRADE PIKE-SAN ISABEL NATIONAL FOREST & CIMMARRON AND COMANCHE NATIONAL GRASSLANDS 010150-1 GENERAL REQUIREMENTS SECTION 010150 GENERAL REQUIREMENTS PART 1 – SUMMARY OF WORK 1.1 DESCRIPTION A. Work for this project requires the contractor to be responsible for supplying all labor, materials, equipment, utilities, miscellaneous items, freight and delivery and all necessary valid licenses and permits for the following: 1. Waste Water System: a. Replace sewer lines in new locations b. Replace septic tanks in specified location c. Install new leach field as shown 2. Water System: a. Replace existing hydrants (Monument only) b. Replace water line (Fairplay) 1.2 LOCATION A. This project is located at the following sites: 1. Fairplay Work Center, Fairplay, Colorado 2. Lake George Work Center, Lake George, Colorado. 3. Monument Fire Center, Monument, Colorado. 4. AG Ranch Work Center, Shawnee, Colorado 1.3 GENERAL SITE CONDITIONS AND WEATHER A. The elevation of Fairplay Work Center, Lake George Work Center, Monument Fire Center, and AG Ranch are approximately 10,000, 8,100, 7,100 and 8,100 feet above mean sea level, respectively. The project sites are open year around. 1.4 USE OF PREMISES A. Use of Site: Confine constructions operations to immediate area of work. Do not disturb portions of Project site beyond areas in which the Work is indicated. B. Full Government Occupancy: Except as defined in “Work Restrictions” in this section, the government will occupy the site and buildings during entire construction period. Cooperate with Government during construction operations to minimize conflicts and facilitate Government usage. Perform the Work so as not to interfere with Government's day-to-day operations. C. Driveways and Entrances: Keep driveways, parking areas, loading areas and entrances serving premises clear and available to Government, Government's employees, and emergency vehicles at all times. Do not use these areas for parking or storage of -- 5 of 136 -- PIKE UNDERGROUND UTILITIES UPGRADE PIKE-SAN ISABEL NATIONAL FOREST & CIMMARRON AND COMANCHE NATIONAL GRASSLANDS 010150-1 GENERAL REQUIREMENTS materials. Do not close or obstruct walkways, corridors, or other occupied or used facilities without written permission from Government and authorities having jurisdiction. 1. Schedule deliveries to minimize use of driveways and entrances. 2. Schedule deliveries to minimize space and time requirements for storage of materials and equipment on-site. 1.5 WORK RESTRICTIONS A. Nonsmoking Buildings: Smoking is not permitted within the buildings or within 25 feet (8 m) of entrances, operable windows, or outdoor air intakes. B. Do not schedule work during holidays, weekends, or between 6:00 PM to 7:00 AM without written approval from the Contracting Officer. C. Minimize the length of time the Work Center water distribution system is non- operational. Where possible, install the new water distribution system while the existing water service is operational. D. Coordination of work with other Contractors: 1. If required, coordinate construction schedule and work activities with the other contractors and Contracting Officer to prevent delays or work stoppages to either contract. 2. Notify the Contracting Officer if conflicts cannot be resolved. 1.6 CONTRACTOR’S RESPONSIBILITIES A. Provide adequate

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Similar Active Opportunities (NAICS 237110)