What this opportunity is
The Department of Agriculture is seeking a contractor for the Pike Underground Utility Upgrade project, which involves the replacement of sewer lines, waterlines, and septic systems in the Pike-San Isabel National Forest and surrounding areas in Colorado. This opportunity is set aside for total small businesses under FAR 19.5, making it suitable for small contractors with relevant experience in utility upgrades and construction. The notice type is a Combined Synopsis/Solicitation, indicating that interested businesses should track the opportunity closely for bidding details and requirements.
Analysis by Mindy, grounded in the SAM.gov notice.
Description
UNITED STATES
DEPARTMENT OF
AGRICULTURE
FOREST SERVICE
REGION 2
PIKE - SAN ISABEL
NATIONAL
FORESTS &
CIMARRON AND
COMANCHE
NATIONAL
GRASSLANDS
PIKES PEAK,
SOUTH PARK, &
SOUTH PLATTE
RANGER DISTRICTS
Pike Underground Utilities
Upgrade
Project Manual
May 1, 2026
-- 1 of 136 --
PIKE UNDERGROUND UTILITIES UPGRADE
PIKE-SAN ISABEL NATIONAL FOREST
& CIMARRON AND COMANCHE NATIONAL GRASSLANDS
001500 - 1
LIST OF DRAWINGS & SPECIFICATIONS
SECTION 001500
PIKE UNDERGROUND UTILITES UPGRADE
LIST OF DRAWINGS AND SPECIFICATIONS
PART 1 – GENERAL
1.1 DESCRIPTION
A. List of Contract Drawings:
1. Index of Sheets:
T1.1 Title Sheet
T1.2 General Notes
C1.1 Lake George Site Plan: Replacement Sewer Lines
C1.2 Section Detail: LG Office Sewer Lines
C1.3 Section Detail: LG Sepic System
C2.1 MFC Site Plan: Replacement Sewer Lines
C2.2 MFC Site Plan: Replacement Hydrants
C2.3 Section Detail: MFC Classroom Sewer Lines
C3.1 Fairplay WC Site Plan: Replacement Waterline
C4.1 AG Ranch WC Site Plan: Septic Tank Replacement
D1.1 Details: Lake George Septic
D1.2 Details: Lake Geroge Septic 2
D1.3 Details: Hydrant and Trench
D1.4 Details: AG Ranch Septic Tanks
14 Total Plan Sheets in this Contract
B. List of Contract Specifications
1. Index of Specifications
DIVISION 1 - GENERAL REQUIREMENTS
Section 001500 List of Drawings and Specifications
Section 010150 General Requirements
Section 010250 Definition of Items and Measurement and Payment
Section 011500 Hazardous Materials Requirements
Section 014000 Quality Requirements
DIVISION 2 – EXISTING CONDITIONS
Section 024119 Selective Demolition
DIVISION 22 - PLUMBING
Section 221316 Sanitary Waste Piping
DIVISION 26 - ELECTRICAL
Section 260500 Electrical Materials and Methods
-- 2 of 136 --
PIKE UNDERGROUND UTILITIES UPGRADE
PIKE-SAN ISABEL NATIONAL FOREST
& CIMARRON AND COMANCHE NATIONAL GRASSLANDS
001500 - 2
LIST OF DRAWINGS & SPECIFICATIONS
DIVISION 31 - EARTHWORK
Section 311100 Clearing and Grubbing
Section 312250 Earthwork
Section 312317 Trenching, Bedding, and Backfill for Utilities
Section 312500 Temporary Erosion and Sedimentation Control
DIVISION 32 – EXTERIOR IMPROVEMENTS
Section 321313 Concrete for Minor Structures
Section 329219 Seeding
DIVISION 33 - UTILITIES
Section 331116 Water Distribution
Section 331219 Water Hydrants
Section 333110 Sanitary Sewerage
END OF SECTION 001500
-- 3 of 136 --
PIKE UNDERGROUND UTILITIES UPGRADE
PIKE-SAN ISABEL NATIONAL FOREST
& CIMARRON AND COMANCHE NATIONAL GRASSLANDS
001500 - 3
LIST OF DRAWINGS & SPECIFICATIONS
This page intentionally left blank.
-- 4 of 136 --
PIKE UNDERGROUND UTILITIES UPGRADE
PIKE-SAN ISABEL NATIONAL FOREST
& CIMMARRON AND COMANCHE NATIONAL GRASSLANDS
010150-1
GENERAL REQUIREMENTS
SECTION 010150
GENERAL REQUIREMENTS
PART 1 – SUMMARY OF WORK
1.1 DESCRIPTION
A. Work for this project requires the contractor to be responsible for supplying all labor,
materials, equipment, utilities, miscellaneous items, freight and delivery and all
necessary valid licenses and permits for the following:
1. Waste Water System:
a. Replace sewer lines in new locations
b. Replace septic tanks in specified location
c. Install new leach field as shown
2. Water System:
a. Replace existing hydrants (Monument only)
b. Replace water line (Fairplay)
1.2 LOCATION
A. This project is located at the following sites:
1. Fairplay Work Center, Fairplay, Colorado
2. Lake George Work Center, Lake George, Colorado.
3. Monument Fire Center, Monument, Colorado.
4. AG Ranch Work Center, Shawnee, Colorado
1.3 GENERAL SITE CONDITIONS AND WEATHER
A. The elevation of Fairplay Work Center, Lake George Work Center, Monument Fire Center,
and AG Ranch are approximately 10,000, 8,100, 7,100 and 8,100 feet above mean sea
level, respectively. The project sites are open year around.
1.4 USE OF PREMISES
A. Use of Site: Confine constructions operations to immediate area of work. Do not disturb
portions of Project site beyond areas in which the Work is indicated.
B. Full Government Occupancy: Except as defined in “Work Restrictions” in this section,
the government will occupy the site and buildings during entire construction period.
Cooperate with Government during construction operations to minimize conflicts and
facilitate Government usage. Perform the Work so as not to interfere with Government's
day-to-day operations.
C. Driveways and Entrances: Keep driveways, parking areas, loading areas and entrances
serving premises clear and available to Government, Government's employees, and
emergency vehicles at all times. Do not use these areas for parking or storage of
-- 5 of 136 --
PIKE UNDERGROUND UTILITIES UPGRADE
PIKE-SAN ISABEL NATIONAL FOREST
& CIMMARRON AND COMANCHE NATIONAL GRASSLANDS
010150-1
GENERAL REQUIREMENTS
materials. Do not close or obstruct walkways, corridors, or other occupied or used
facilities without written permission from Government and authorities having
jurisdiction.
1. Schedule deliveries to minimize use of driveways and entrances.
2. Schedule deliveries to minimize space and time requirements for storage of
materials and equipment on-site.
1.5 WORK RESTRICTIONS
A. Nonsmoking Buildings: Smoking is not permitted within the buildings or within 25 feet
(8 m) of entrances, operable windows, or outdoor air intakes.
B. Do not schedule work during holidays, weekends, or between 6:00 PM to 7:00 AM
without written approval from the Contracting Officer.
C. Minimize the length of time the Work Center water distribution system is non-
operational. Where possible, install the new water distribution system while the existing
water service is operational.
D. Coordination of work with other Contractors:
1. If required, coordinate construction schedule and work activities with the other
contractors and Contracting Officer to prevent delays or work stoppages to either
contract.
2. Notify the Contracting Officer if conflicts cannot be resolved.
1.6 CONTRACTOR’S RESPONSIBILITIES
A. Provide adequate …