Repair, restore, and waterproof the roof of the office building at Naval Weapons Station Earle

HOMELAND SECURITY, DEPARTMENT OF

Notice type
Combined Synopsis/Solicitation
Solicitation #
70FBR226Q00000020
NAICS
238160
PSC
Z2JZ
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
July 16, 2026
Response due
August 7, 2026
Place of performance
Colts Neck, NJ

What this opportunity is

The Department of Homeland Security is seeking a contractor to repair, restore, and waterproof the roof of an office building at Naval Weapons Station Earle in New Jersey. This opportunity is set aside for total small businesses under NAICS 238160, which covers roofing contractors. The notice type is a Combined Synopsis/Solicitation, indicating that interested firms should track the opportunity closely and prepare to submit proposals rather than simply expressing interest. The project involves assessing the roof's condition and implementing effective repair methods to ensure long-term durability and leak prevention.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

Federal Emergency Management Agency STATEMENT OF OBJECTIVE (SOO) FOR: Naval Weapon Station, Earle, Roof Repair for Office Building Kendall Feaster, Contracting Officer (CO) DEPARTMENT OF HOMELAND SECURITY (DHS) Statement of Objectives (SOO) For Roof Repair for Office Building Purpose The objective of this project is to repair, restore, and waterproof the roof of the office building to provide a leak-free environment, prevent damage to internal inventory and equipment, and maximize the operational lifespan of the roof. Background The Federal Emergency Management Agency (FEMA) is seeking to establish a service contract for roof repair services at Building C-54, Naval Weapons Station Earle, Colts Neck, NJ 07722. Given FEMA’s critical mission to respond rapidly to disasters, it is essential that the roof always remains completely leak-free and fully mission capable. In 2022, FEMA successfully addressed warehouse roof leaks using a commercial-grade epoxy sealant. This solution may also be suitable for the office roof. The contractor is expected to evaluate the office roof and recommend the most effective repair method, which may include the use of epoxy or other industry-standard materials, to ensure long-term leak prevention and durability. Scope or Mission Mission The scope of this effort is to secure professional roof repair services for our office building, which has a roof area of approximately 22,490 square feet. The contractor will be responsible for conducting a thorough assessment of the roof’s current condition, identifying areas of damage or concern, and recommending the most effective solutions - whether that involves targeted repairs, full restoration, or sealing as appropriate. We are seeking a contractor with demonstrated expertise in commercial roof repair who can provide informed recommendations and implement high-quality, durable solutions. The objective is to address existing issues, prevent future deterioration, and make sure the ongoing safety, integrity, and functionality of the facility. Scope of Work (Summary) The Contractor shall furnish all labor, materials, equipment, and supervision necessary to repair identified defects. Key areas of work include to include, but not limited to the following: Membrane Repair: Repair or replace damaged, blistered, or punctured areas of the roofing membrane to ensure total weather-tightness. Flashing and Penetrations: Re-seal or replace flashing around HVAC units, vents, skylights, and pipe penetrations. Repair or replace deteriorated coping caps along parapet walls. Drainage Systems: Clear and restore all roof drains, gutters, scuppers, and downspouts to allow proper water flow and prevent ponding. Structural Decking: Inspect and repair any rotted, rusted, or structurally compromised roof decking discovered during the repair process. Performance Objectives and Requirements: The contractor shall conduct a comprehensive inspection of the existing roof to identify all leaks and areas needing repair, coordinating site visits with the designated Contracting Officer’s Representative (COR) and Contracting Officer (CO) to determine the full scope of work. Within 5 days of the site visit, the contractor shall provide recommended solutions, including an estimated completion timeline, detailed cost estimate, and a summary of all necessary repairs. Performance Criteria: Watertightness: The completed roof must be entirely leak-free and capable of withstanding local weather extremes. Code Compliance: All repairs must comply with New Jersey Building Codes (if applicable). Asset Protection: The contractor must implement a property protection plan to prevent interior dust, debris, and water intrusion during repair. Contractor Deliverables: Design and Methodology: Provide a detailed technical approach, including recommended materials (i.e. such as TPO, EPDM, or modified bitumen) and an execution plan. Warranties: Offer a minimum of 3 years + no-leak guarantee covering both workmanship and materials. Safety Plan: Submit a site-specific safety and risk management plan for working at industrial heights. Period of Performance: All repairs and final cleanup must be completed within 1 year from the date of award. FEMA will defer to the contractor as to when is the best time to perform the above-mentioned repairs. Place of Performance Naval Weapons Station Earle – FEMA Building C-54 201 State Route 34 Colts Neck, NJ 07722 Operating Constraints Contractor employees shall perform all work between the hours of 7:00 AM and 4:30 PM EST, Monday through Friday (except Federal holidays). However, there may be occasions when Contractor employees shall be required to work other than normal business hours, including weekends and holidays, to fulfill requirements. Applicable Documents or References 1. Naval Weapons Station Earle – FEMA Building C-54 floor plan (attached). 2. Security Information for NWS Earle: Naval Weapons Station Earle’s security performs a background check utilizing the NAVSEC 5512, form will be provided to all contractors requiring access. Instructions will be provided with form. All personnel entering the Naval Base. Driver’s must be U.S. citizens and are required to present a valid Real ID, driver’s license, vehicle registration, and proof of insurance. All commercial vehicles, exterior and interior, will be thoroughly inspected by Naval base security. Privacy Clauses HSAR 3052.240-71 CONTRACTOR EMPLOYEE ACCESS (HSAR DEVIATION 25-12) (Effective November 3, 2025) Controlled Unclassified Information (CUI) is any information the Government creates or possesses, or an entity creates or possesses for or on behalf of the Government (other than classified information) that a law, regulation, or Governmentwide policy requires or permits an agency to handle using safeguarding or dissemination controls. This definition includes the fol

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Similar Active Opportunities (NAICS 238160)