Sources Sought for DVR Autoclave Preventive Maintenance and Repair Services

HEALTH AND HUMAN SERVICES, DEPARTMENT OF

Notice type
Sources Sought
Solicitation #
NIH-SS-PCA-ORS-02313
NAICS
811210
PSC
J065
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
July 10, 2026
Response due
July 20, 2026
Place of performance
Bethesda, MD

What this opportunity is

The Department of Health and Human Services is seeking preventive maintenance and repair services for autoclave equipment in Maryland, set aside for total small businesses. The work involves routine maintenance and callback repair for equipment at locations in Bethesda and Poolesville. As a sources sought notice, this is a preliminary step to determine interested vendors, rather than a solicitation for bids.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

1 Statement of Work DVR Autoclave Preventive Maintenance and Repair Services 1. BACKGROUND INFORMATION: The Service Provider will service DVR autoclave equipment located in Bethesda and Poolesville, MD. The autoclave equipment is regularly utilized for routine sterilization of caging, equipment, water, diets, bedding, and waste. DVR autoclaves are critical to maintaining the health and well-being of the animals, NIH’s AAALAC accreditation, and overall mission. 2. OBJECTIVES: This agreement entails routine preventative maintenance (PM) of DVR autoclave equipment located in Bethesda and Poolesville, MD, to ensure that the equipment covered operates with maximum dependability and efficiency. This agreement requires four PM visits per year, spaced roughly three months apart. At each PM visit, the contractor shall perform all inspections, tests, services, and maintenance activities as recommended by the manufacturer or are necessary to maintain the system in proper working condition, as outlined in the Guide For The Care and Use of Laboratory Animals, Eighth Edition, where there is significant guidance provided on animal environment, housing, and physical plant requirements. This agreement also entails callback repair and special projects service. All replacement parts (excluding parts and components listed) and miscellaneous hardware on each autoclave are funded via separate purchase requisition after review and approval of a detailed quote. Successful contract performance shall include the prevention or early detection and correction of deficiencies, the proper repair and use of test equipment to prevent equipment damage during repairs or inspections, and the proper use of test equipment to prevent equipment damage during repairs or inspections. The contract period shall be for one (1) year with the potential of four (4) option years for Autoclave equipment. The contract period of performance shall entail a base year plus four, one-year option periods: Base Year: September 1, 2026 – August 31, 2027 Option Year One: September 1, 2027 – August 31, 2028 Option Year Two: September 1, 2028 – August 31, 2029 Option Year Four: September 1, 2029 – August 31, 2030 -- 1 of 6 -- 2 3. Equipment description, location(s), and summary: FACILITY ROOM/CORRIDOR MANUFACTURER MODEL S/N 10A 219 Amsco 2323 011918907 10A 319 Getinge 133LS 011918906 10A 1.00E+110 Getinge 833LS-E 25488-01 10A 112 BetaStar 497286-SHA-HHR 25488-01 10B2 Cagewash BMT SLV497355- 2PA AC20024 14A 138 BetaStar VR567272 14A 139 Getinge 72x84 30165 14E 114C Amsco 3012 0113997-05 14E 114C Amsco 250-LS 32341906 14E 103 Sterivap 9615-1FD 5170525 14F East Corridor BetaStar LS-648484 21241-01 102 Corridor Getinge 733LS 08B07782 103 467 BetaStar VR-498686-SHA PA03299301 103 101 BetaStar LS11 202038 PA03531501 4. Preventive Maintenance: The contractor will work with the individual Government Animal Facility Managers to establish a mutually acceptable schedule for each PM visit. All work will be performed during regular business hours, Monday through Friday, excluding federal holidays. All labor for inspections is included under the agreement, excluding replacement parts and repairs, which are to be funded by a separate purchase requisition after review and approval of a detailed quote. 5. DVR Animal Facility Classifications and Entry Procedures: Each animal facility is classified according to the pathogen status of the animals housed in that facility. Therefore, entrance requirements vary. DVR animal facilities are classified as conventional, limited access, specific pathogen free (SPF), for purposes of disease containment or the prevention of cross- contamination between facilities. A description of each classification and the order of entry between classifications follows: Conventional: -- 2 of 6 -- 3 Protective clothing requirements for conventional facilities will be indicated by signage at the facility entrance. Strict adherence is required. Entering any SPF facility is prohibited on the same day after entering a Conventional Facility, unless the individual showers and changes clothing first. Limited Access: Protective clothing requirements for Limited Access facilities will be indicated by signage at the facility entrance. Strict adherence is required. Entering any SPF facility is prohibited on the same day after entering a Limited Access Facility, unless the individual showers and changes clothing first. Specific Pathogen-Free: SPF facilities are considered the “cleanest.” Therefore, entry into an SPF facility should occur first if multiple facilities are to be visited on the same day, unless the individual showers and changes clothing before entry. Protective clothing requirements for SPF facilities will be indicated by signage at the facility entrance. Strict adherence is required. 6. Responsibility for Service Utilities: The portions of utility connections servicing the Autoclave equipment for which the Contractor shall be responsible include: Electrical: The Contractor shall inspect, maintain, repair, and/or replace all electrical wiring and components from the load side of the building main disconnect to all Autoclave equipment. Steam: The Contractor shall maintain, repair, and/ or replace as needed, all steam regulators, piping, piping insulation, gauges, and all steam components from the main shut-off valve feeding the Autoclave equipment to the Autoclave equipment. The Contractor shall maintain, repair, and/or replace all pumps, piping, valves, strainers, and steam traps on all steam condensate lines serving the Autoclave equipment back to the next-in-line shut-off valve. The minimum steam supply pressure is 50 psi. The Contractor shall notify the Government Animal Facility Manager of any indication of low steam pressure as soon as it is discovered. Domestic hot water and city water: The Contractor shall inspect, maintain, repair, and/or replace as needed, all pip

Source: SAM.gov, as posted. Verify the current solicitation before responding.