Z--Remove and Replace Above Ground Fuel Storage Fuel
INTERIOR, DEPARTMENT OF THE
Notice type
Combined Synopsis/Solicitation
Solicitation #
140FC326Q0033
NAICS
237120
PSC
Z2NA
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
June 16, 2026
Response due
July 18, 2026
What this opportunity is
The Department of the Interior is seeking a contractor to remove and replace above-ground fuel storage tanks and associated equipment, including pumps and safety accessories. This opportunity is set aside for total small businesses under NAICS 237120. Interested vendors should note that this is a combined synopsis/solicitation, meaning they will need to track the notice closely for further details rather than submit a bid immediately.
Analysis by Mindy, grounded in the SAM.gov notice.
Description
FIREGUARD® HORIZONTAL STORAGE
TANK MANUAL FILL-RITE® PUMP
Pump
Accessories
Pressure
Vacuum
Vent
Level Gauge
Leak Indicator
Fill Accessories
Storage Tank
48" Diameter
FEATURES
1. Storage Tank
2. Fill Accessories
3. Level Gauge
4. Leak Detection
5. Pressure/Vacuum Vent
6. Pump Accessories
7. Platform Ladder
FIREGUARD® HORIZONTAL STORAGE
TANK MANUAL FILL-RITE® PUMP TrueNorthSteel.com | Tank@TrueNorthSteel.com
Document #4000-0026
Pump
Accessories
Pressure
Vacuum
Vent
Fill Accessories
Level Gauge
Platform Ladder
Leak Indicator
Storage Tank
64" Diameter
-- 1 of 5 --
FEATURE 1: STORAGE TANK
1. Steel tank of specified size and color
2. Two Morrison Bros. Co. emergency vents for
primary and secondary tanks
3. One 2” NPT fitting for secondary leak detection
4. Five 2” FNPT fittings standard, other sizes and
customized layout available upon request
5. Saddle supports standard
6. Pump platform and piping included on tanks of 64”
diameter and over
STANDARD SIZES AND PART NUMBERS
1006-0320 38”X5’ 300 Gallon
1006-0315 48”X6’ 550 Gallon
1006-0319 48”X11’ 1000 Gallon
1006-0316 64”X6’ 1000 Gallon
1006-0268 64”X12’ 2000 Gallon * Contact TrueNorth Steel Sales for
assistance with customizing tanks.
TrueNorthSteel.com | Tank@TrueNorthSteel.com
Secondary E-Vent
Primary E-Vent
Saddle Supports
2" FNPT Fittings
2" FNPT
Leak Detection
FIREGUARD® HORIZONTAL STORAGE
TANK MANUAL FILL-RITE® PUMP
FEATURE 2: FILL ACCESSORIES
STANDARD PART NUMBERS
TB000333 Fill cap, 2”, Morrison Bros. Co. 178-0300 AC
TB001369 Pipe nipple, 2”, close-length
TB002054 Optional spill container, 3 1/2 gallon Morrison
Bros. Co. 517-000 AC
TB001395 Plug, 2”, for all open fittings
* Contact TrueNorth Steel Sales for assistance with
alternative fill accessories if needed.
Fill Cap
2" Pipe Nipple
2" FNPT Tank Fitting TB001395
Fill Cap
Spill Container
FEATURE 3: LEVEL GAUGE
STANDARD PART NUMBERS
3900-0998 Gauge, At-A-Glance, Model D-2-56, 48” Fireguard® tank
TB000501 Gauge, At-A-Glance, Model D-2-72, 64” Fireguard® tank
* Contact TrueNorth Steel Sales for assistance with
alternative gauge accessories if needed. 2" FNPT Tank Fitting
Level Gauge
Pump Platform
& Piping
-- 2 of 5 --
FEATURE 4: LEAK DETECTION
STANDARD LEAK INDICATOR GAUGE
3900-0867 Morrison Bros. Co. 724 Leak Indicator Gauge
* Contact TrueNorth Steel Sales for assistance with
alternative leak detection accessories if necessary.
TrueNorthSteel.com | Tank@TrueNorthSteel.com
2" FNPT Tank Fitting
Leak Indicator Gauge
FIREGUARD® HORIZONTAL STORAGE
TANK MANUAL FILL-RITE® PUMP
FEATURE 5: PRESSURE/VACUUM VENT
STANDARD PART NUMBERS
TB002185 Pressure/vacuum vent, Morrison Bros. Co.
749-0100 AV
3200-0616 Riser pipe, 2”X7’, galvanized
* Contact TrueNorth Steel Sales for assistance with
alternative venting accessories if needed. 2" FNPT Tank Fitting
Pressure/Vacuum Vent
-- 3 of 5 --
TrueNorthSteel.com | Tank@TrueNorthSteel.com
FIREGUARD® HORIZONTAL STORAGE
TANK MANUAL FILL-RITE® PUMP
FEATURE 6: PUMP ACCESSORIES
ITEMS FOR GASOLINE PUMPS
TB001533 Pump, Fill-Rite® 700, 20 gpm, 3/4”X12’ hose, no meter
TB001534 Pump, Fill-Rite® 701, 20 gpm, 3/4”X12’ hose, mechanical meter
TB001045 Optional nozzle, Harco 11T, automatic
TB000354 Filter head, 3/4” NPT
TB000363 Filter
TB001338 3/4”X7” pipe nipple, 1/pump (metered pump)
TB001355 3/4”X3” pipe nipple, 2/pump (non-metered pump)
TB001242 3/4”X90” pipe elbow, 1/pump (non-metered pump)
ITEMS FOR DIESEL PUMPS
3900-0268 Pump, Fill-Rite® 711, 20 gpm, 1”X18’ hose, mechanical meter
TB001531 Pump, Fill-Rite® 319, 35 gpm, 1”X18’ hose, digital meter
TB000355 Filter head, 1” NPT
TB000376 Filter
TB001349 1”X8” pipe nipple, 2/pump
SUCTION PIPES
3200-1437 1 1/4”X55” pipe, 48” diameter tank
3200-1020 1 1/4”X71” pipe, 64” diameter tank
Metered Pump
Filter & Head
Pipe Nipple
Nozzle
Suction
Pipe
Hose
tank
48" diameter
Pump
Non-Metered
Pipe Nipples
& Elbow
Filter & Head
Nozzle
Hose
tank
64" diameter
* Platform, piping and suction
pipe included; shipped installed
Pump, fittings, filter
ordered separately
and shipped loose
Non-Metered Pump System
Metered Pump System
64” with Pump Platform
-- 4 of 5 --
FEATURE 7: PLATFORM LADDER
STANDARD LADDER ASSEMBLIES, LENGTH, AND TANK SIZE
2000-2856 48” - size 48 diameter tanks
2000-2855 60” - size 64 diameter tanks
2000-2857 72” - size 72 diameter tanks
2000-2858 84” - size 84 diameter tanks
Ships as an installed option on the tank when specified through sales request.
TrueNorthSteel.com | Tank@TrueNorthSteel.com
Tank Tabs
and Bolts
Le
Ln
ag
dt
d
h
er
Platform Ladder
Assembly
34"
FIREGUARD® HORIZONTAL STORAGE
TANK MANUAL FILL-RITE® PUMP
Bolt-on ladder assembly, painted finish. Color is same as tank unless specified otherwise.
Grip-strut standing platform for access to fittings on top of tank.
(other sizes available in 1’ increments up to 132” length)
* Contact TrueNorth Steel Sales for assistance with alternative ladder and platform accessories if needed.
0424
-- 5 of 5 --
Source: SAM.gov, as posted. Verify the current solicitation before responding.
Pursue this opportunity with Mindy
See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.
View the original notice on SAM.gov ↗Similar Active Opportunities (NAICS 237120)
Jet A Fuel Storage Tank Systems
AGRICULTURE, DEPARTMENT OF · Combined Synopsis/Solicitation · due June 23, 2026
Solicitation for Grand Forks Fueling System Repairs
DEPT OF DEFENSE · Solicitation · due July 10, 2026
Y1NA--CON | NRM 653-23-100 | Remove Replace Underground Fuel Tanks
VETERANS AFFAIRS, DEPARTMENT OF · Solicitation · due June 17, 2026
Jet A Fuel Storage Tank Systems
AGRICULTURE, DEPARTMENT OF · Combined Synopsis/Solicitation · due June 18, 2026
Y1NA--CON | NRM 653-23-100 | Remove Replace Underground Fuel Tanks
VETERANS AFFAIRS, DEPARTMENT OF · Solicitation · due June 17, 2026
Replace Fuel Tanks and Associated Lines - Rec Camp
DEPT OF DEFENSE · Solicitation · due June 17, 2026