Z2DB--Renovate Imaging and Catheterization Lab 570 21 220 Fresno VA Medical Center Fresno

VETERANS AFFAIRS, DEPARTMENT OF

Notice type
Solicitation
Solicitation #
36C26126R0045
NAICS
236220
PSC
Z2DB
Set-aside
Service-Disabled Veteran-Owned Small Business Set Aside
Posted
July 14, 2026
Response due
July 23, 2026
Place of performance
Fresno, CA

What this opportunity is

The Department of Veterans Affairs is buying renovation services for an imaging and catheterization lab at the Fresno VA Medical Center. This opportunity is set aside for Service-Disabled Veteran-Owned Small Business. As a solicitation notice, businesses should track the opportunity to prepare for a potential bid.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

Level of floor ± 1 16" (2mm) per 39" (1m) within this area. Table Safety Zone Motorized Movement Line C1 C2 C3 413 16" 84 1 8" 22" 90" 78" C1 C3 2"-33" 88" 44"-75" 78" 90" 90" C2 75" 16" 106 5 16 " CEILING HEIGHT 106 5 16 " CEILING HEIGHT K1 EQUIPMENT LIST TAG QTY DESCRIPTION ============================================================================================== C1 1 Tandem HarmonyAIR Adj Arm Spring - A Series-Anesthesia, Accessory Arm(s) C2 1 Tandem HarmonyAIR Fixed - A Series-Equipment, Surgical Light(s) & Accessory Arm(s) C3 1 HarmonyAIR Monitor Carrier-Monitor Carrier K1 1 HarmonyAIR A-Series Integrated Wall Control A SERIES LIGHT CONDUIT SCHEDULE FROM - TO QUANTITY SIZE RESPONSIBILITY K1 - C2 2 .75" ELECTRICAL CONTRACTOR LIGHT CONDUIT SCHEDULE NOTES 1. .5" CONDUIT FOR AC POWER TO K1; 3 COND. 10AWG WIRE INPUT AC SUPPLY - 120V-240VAC, 7A-3A, 50/60Hz 2. LIGHTING CONDUIT RUNS NOT TO EXCEED 25 FEET 3. CONDUIT REQUIREMENTS FOR LIGHTS AND CONNECT POINT ALSO REFERENCED WITHIN THE EQUIPMENT DRAWINGS FOR THE SPECIFIED SURGICAL LIGHT WALL CONTROL SYSTEM 4. DC SUPPLY LIGHTHEAD CABLES REQUIRE 1" CONDUIT WHEN DOUBLE RUNS ARE REQUIRED (LONG RUNS) 5. REFER TO APPROPRIATE EQUIPMENT SPECIFICATIONS TO ENSURE THAT THE MOST CURRENT & DETAILED INFORMATION OF THIS LIGHT SYSTEM IS UTILIZED MOUNT C2 & C3 LIMITED UPPER ARM ROTATIONS AT WALL 2 1 OF 1 SCALE: 1/4" = 1'-0" PROPOSED EQUIPMENT LAYOUT 1 SCALE: 1/4" = 1'-0" FOOT END EQUIPMENT ELEVATION 2 SCALE: 1/4" = 1'-0" FOOT END EQUIPMENT ELEVATION 3 3 1 OF 1 Clea / Table ℄ AD7 Table Floor Plate ℄ N1 N1 3 N2 N1 10'-11" 16'-9" Level of floor ± 1 16" (2mm) per 39" (1m) within this area. x2 N1 x2 REVISION HISTORY REVISION # DESCRIPTION PLANNER/DATE 1 UPDATED VENDOR CAD BACKGROUND; RELOCATED K1 JTP/09SEP2022 * THE SERVICE CLEARANCES INDICATED DO NOT MEET THE MINIMUM SAFETY CLEARANCES RECOMMENDED IN THE EQUIPMENT DRAWINGS PROVIDED BY STERIS CORPORATION Planning & Design Group STERIS 5960 Heisley Road Mentor, OH 44060 USA 800-548-4873 Dr Ck Date Scale H- C STERIS drawings do not supersede the drawings from the architect of record. ALL STERIS CEILING EQUIPMENT LOCATIONS ARE PRELIMINARY AND MUST BE REVIEWED AGAINST MOST CURRENT IMAGING VENDOR DRAWINGS. THIS DRAWING BASED ON: DATE REVISION # DESCRIPTION F 08/16/2022 PHILIPS - AZURION 7 C20 FLEXARM 4300MM -N-WES190300FF 1/4" = 1'-0" 12AUG2022 JTP 6R1 0654 PAGE 1 OF 1 PARTIAL FLOOR PLAN CATH LAB PROPOSED EQUIPMENT LAYOUT VA CENTRAL CALIFORNIA HEALTH CARE SYSTEM FRESNO, CALIFORNIA -- 1 of 1 --

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗