6525--FY26: AlignRT DoseRT Therapy CT Scanner

VETERANS AFFAIRS, DEPARTMENT OF

Notice type
Sources Sought
Solicitation #
36C24826Q0435
NAICS
334510
PSC
6525
Posted
July 16, 2026
Response due
April 15, 2026
Place of performance
Bay Pines, FL

What this opportunity is

The Department of Veterans Affairs is seeking information from potential contractors to supply AlignRT DoseRT Therapy CT Scanners. This opportunity is suitable for small businesses with expertise in the manufacture of medical imaging equipment, specifically those classified under NAICS code 334510. As this is a Sources Sought notice, interested parties should track the solicitation process for future updates, as no formal solicitation has been issued yet.

Analysis by Mindy, grounded in the SAM.gov notice.

Description

Sources Sought Notice DESCRIPTION THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of all qualified sources to fulfill a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 8, is conducting market research to identify potential sources which can provide the following supplies in support of the Bay Pines, VA Health Care System. As part of efforts to expand Radiation Oncology, this system must be compatible with the Varian TrueBeam linear accelerator. It must have interoperability with Varian Linacs via MMI in order to interface directly for auto beam hold capabilities, send to couch features, auto patient import and more.  The Miami VAMC is currently using the VisionRT s Surface Guided Radiation Therapy (SGRT) in one vault and seeking to add another system to better serve the Veteran population. The video module of the system shall allow for a multi-angle, real-time view of the patient's overall alignment relative to their reference position during setup and monitoring by using an outline of the reference surface and a live video stream of the patient. The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of all qualified sources who can provide a Brand Name or Equal system to AlignRT Surface Guided Radiation Therapy (SGRT) system. Functions to be performed: Surface Guided Radiation Therapy (SGRT) system that allows real-time tracking of patients before and during radiation therapy. Functions must use contact-free techniques to track patients skin surfaces with sub-millimetric accuracy ranging below 0.5mm in all six degrees of freedom. Ensures radiation is only delivered when patients are correctly positioned. System must ensure accurate and reproductible patient setup and monitoring during dose delivery. System must have the ability to automatically pause treatment due to expected and unexpected patient adjustments made during dose delivery and treatment. Shall be compatible with Varian TrueBeam Linear Accelerator: Shall be completely integrated with Varian TrueBeam Linear Accelerator through MMI interface for GATING (Beam Hold) and applying directly 6DOF (Degrees of Freedom) couch shifts to the linac in case of patient motion, assuring the safe and accurate delivery of radiation. System shall be able to perform the following therapies and examinations: DIBH (Deep Inspiration Breath Hold) General Breast SRS (Stereotactic Radiosurgery) SBRT (Stereotactic Body Radiation Therapy) Head and Neck Breath Hold SBRT Sarcoma Prostate Software and Interfacing Requirements: Shall be compatible with Varian TrueBeam Linear Accelerator: Shall be able to be completely integrated with Varian TrueBeam Linear Accelerator through MMI interface for GATING (Beam Hold) and applying directly 6DOF (Degrees of Freedom) couch shifts to the linac in case of patient motion, assuring the safe and accurate delivery of radiation. Shall include HD camera unit. Shall utilize a minimum of three (3) mounted HD camera units to allow image capture from any combination of the three (3) camera units. Shall include workstation: Workstation shall be at the treatment console in sync with a monitor, keyboard, and mouse in the treatment room. Shall include patient tracking software. Standard and Gated image acquisition (for Beam on Hold) Region of Interest selection and propagation, i.e., selection of skin in face open mask, excluding non-reflective surfaces Image manipulation tools for better image contrast visualization Image Registration (Fusion of actual image and reference CT/TPS image) SSD (Source to Skin Distance) verification especially for 3D plans for every treatment field Calculation and display of couch shifts and new couch coordinates Real Time Surveillance and display of 6 DOF (Degrees of Freedom) shifts: 3 Translations and 3 Rotations Automatic Motion Detection, and ability to put the beam on hold, then resume the treatment safely after new couch shifts are applied. Shall include DICOM import and export modules. The DICOM RT import module must allow contours extracted from CT and TPS (Treatment planning System) to be imported into system as Reference Data or Baseline Data . The DICOM RT export module must allow couch shifts report to be exported to the patient e-Chart in ARIA (Treatment Management System, residing in a single Varian Database) Shall include calibration plate. Flat plate with regular pattern of known dimensions to enable the precise calibration of the system cameras. Shall include PSU for HD camera. To install HD Power supplies using two M8 expansion bolts. Shall include portable device to allow for remote control of key functions. To include 3 Remote Control Units to allow the control of key functions of system software through a Remote-Control Receiver and interface cable. Must include advanced optical set-up and verification of system. Must include 3-camera units using a projector and image sensor to create a 3D surface model of the area of interest by projecting a red light containing a speckle pattern on your skin. The speckle pattern allows the system to reference thousands of points on the skin, acting as virtual tattoos. Must have System accuracy in patient positioning before and during treatment to allows Radiation Oncology to deliver advanced treatment options such as High Dose Single Fraction SRS (using open mask for claustrophobic patients), and SBRT treatments necessitating high accuracy and precision in positioning and Patient Motion Monitoring during treatment. Easy Patient Identification: Must include a software Treatment room Pack that uses (Infra-Red)

Source: SAM.gov, as posted. Verify the current solicitation before responding.

Pursue this opportunity with Mindy

See who holds it now, who else is bidding, and draft your response — grounded in real government data, not generic AI.

View the original notice on SAM.gov ↗

Similar Active Opportunities (NAICS 334510)