Description
ATTACHMENT 2: TECHNICAL SPECIFICATION
CATM RANGE LEAD CLEANING AND SERVICING, BLDG 964/965
SECTION 02 83 18.00 30 Page 1 of 26
18WG 02 83 18.00 30
CATM RANGE LEAD CLEANING AND SERVICING STANDARD
18 WING, KADENA AIR BASE, BASE
(05/2026)
Document No: 18WG 02 83 18.00 30
Issue Date: 26 May 2026
Replaces: 18WG 02 83 00.00 30, 07/21
Source Data: UFGS 02 83 00, 11/18
OPR|OCR: 718 CES/CEIE | 18ORMS/SGXB
1. PART 1 GENERAL
1.1. This specification incorporates the applicable portions of U.S.C.,
CFR, DoDI, UFGS, AFI, and 18th Wing requirements together with
JEGS 2024 requirements to provide a specification applicable to
the servicing and removal of lead-contaminated wastes from the
CATM Range.
1.2. This Technical Specification is valid only for the scope of work
defined in the CATM Lead Cleaning and Servicing contract for
B964/965, Kadena Air Base.
1.3. The publications listed below form a part of this specification to
the extent referenced. The publications are referred to within the
text by the basic designation only.
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION (AIHA)
AIHA Z88.6 (2006) Respiratory Protection - Respirator Use-
Physical Qualifications for Personnel
ASTM INTERNATIONAL
ASTM E1792 (2024) Standard Specification for Wipe Sampling
Materials for Lead in Surface Dust
DoDI 4140.62 Management and Disposition of Disposition of
Material Potentially Presenting an Explosive
Hazard (MPPEH)
JAPAN MINISTRY OF ENVIRONMENT (MOE)
Law No. 137 (as amended) Waste Management and Public
Cleansing Law of 1970
JAPAN MINISTRY OF LABOR (MOL)
Ordinance 32 (as amended) Ordinance for Industrial Safety
and Health, Ordinance 32 of 30 September 1972
JAPAN MINISTRY OF HEALTH, LABOUR AND WELFARE (MHLW)
MHLW Laws (Amendment No. 57 - 2006) Industrial Safety and
Health Law of 1972
NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
29 CFR 1910.1000 Air Contaminants
29 CFR 1926.21 Safety Training and Education
29 CFR 1926.33 Access to Employee Exposure and Medical Records
29 CFR 1926.55 Gases, Vapors, Fumes, Dusts, and Mists
29 CFR 1926.59 Hazard Communication
29 CFR 1926.62 Lead
29 CFR 1926.65 Hazardous Waste Operations and Emergency
-- 1 of 26 --
ATTACHMENT 2: TECHNICAL SPECIFICATION
CATM RANGE LEAD CLEANING AND SERVICING, BLDG 964/965
SECTION 02 83 18.00 30 Page 2 of 26
Response
29 CFR 1926.103 Respiratory Protection
40 CFR 260 - 270
40 CFR 745 Lead-Based Paint Poisoning Prevention in
Certain Residential Structures
UNDERWRITERS LABORATORIES (UL)
UL 586 (2009) UL Standard for Safety, High-Efficiency
Particulate, Air Filter Units
US DEPARTMENT OF DEFENSE (DoD), U.S FORCES JAPAN (USFJ)
JEGS (2024) Japan Environmental Governing Standards
US DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT (HUD)
HUD 6780 (July 2012) Guidelines for the Evaluation and
Control of Lead-Based Paint Hazards in
Housing, Second Edition, (1995; Errata Aug
1996;Rev Ch. 7 - 1997 is also valid.)
1.4. DEFINITIONS
1.4.1. Abatement
1.4.1.1. For the purposes of this specification, abatement means any
measure or set of measures designed to permanently eliminate
lead-dust, lead particles, and lead-contaminated debris.
Abatement includes, but is not limited to:
a) The removal of lead-contaminated projectile fragments,
lead-contaminated dust, and lead-contained filters, the
replacement of expended filters used to contain lead dust
and particles, the removal or and replacement of lead
debris collection buckets that are damaged beyond repair,
and the cleaning of lead-contaminated concrete surfaces;
and
b) All preparation, cleanup, transportation of waste(s),
disposal of waste(s), and post-abatement clearance testing
activities associated with such measures, including the
submission of plans and laboratory analysis results.
c) Abatement does not include renovation, remodeling,
landscaping or other activities not specifically mentioned
in the Statement of Work (SOW).
1.4.2. Action Level
1.4.2.1. Employee exposure, without regard to use of respirators, to an
airborne concentration of lead of 30 micrograms per cubic
meter of air averaged over an 8 hour period in a work
environment.
1.4.3. Area Sampling
1.4.3.1. Sampling of lead concentrations within the lead control area
and inside the physical boundaries, which is representative of
the airborne lead concentrations but is not collected in the
breathing zone of personnel.
-- 2 of 26 --
ATTACHMENT 2: TECHNICAL SPECIFICATION
CATM RANGE LEAD CLEANING AND SERVICING, BLDG 964/965
SECTION 02 83 18.00 30 Page 3 of 26
1.4.4. ARRUSAJ
1.4.4.1. Applicable Regulatory Requirements of the United States and
Japan (ARRUSAJ): Includes all applicable acts, laws,
regulations, standards and other requirements, defined or
undefined in this section, that have been issued by US
federal, DOD, the JEGS, US Air Force, Ministries of the
Government of Japan (GOJ), prefectural government, nationally
recognized standards organization, and other agencies with
legal jurisdiction pertaining to work standards, worker
protection, medical monitoring, waste labeling and storage,
transportation, disposal, and documentation of work activities
involving lead an lead-contained wastes.
1.4.5. Certified Industrial Hygienist (CIH)/Qualified Person (QP)
1.4.5.1. As used in this section, the CIH/QP refers to either a
certified industrial hygienist or other occupation health
field professional trained in the recognition and control of
lead hazards that may be found in the construction working
environment.
1.4.5.2. The CIH/QP is solely responsible for the integration of all
Occupational Health and Environmental Health requirements for
compliance with ARRUSAJ into in the project plans.
a) A CIH must be certified for comprehensive practice by the
American Board of Industrial Hygiene and trained in
accordance with current US federal and State regulations.
b) A QP must be certified under the Ordinance for Industrial
Safety and Health, Ordinance 32 of 30 September 1972.
1.4.5.3. The CIH or QP must be independent of the Contractor and must
have no employee or employer relati…
Source: SAM.gov, as posted. Verify the current solicitation before responding.